Entry  Tue Mar 16 15:10:41 2021, Patrick Sieberer, Pad Sensoren, 25, , 252.7, nominal, Proton, , Good, , , 50, , , , none,  

Start: 14:06
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Tue Mar 16 15:11:00 2021, Patrick Sieberer, Pad Sensoren, 26, , 252.7, nominal, Proton, , Good, , , 100, , , , none,  

Start: 14:20
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Tue Mar 16 15:11:34 2021, Patrick Sieberer, Pad Sensoren, 27, , 252.7, nominal, Proton, , Good, , , 100, , , , none,  

Start: 14:28
Range Shifter Out, Filter 1 IN, Filter 2 IN
Power supply of si-sensor went into compliance, therefore the compliance value was set to 100 uA again
Ende 14:35

Entry  Sat Sep 18 06:20:51 2021, Manuel Christanell, Pad Sensoren, 10, , 62.4, III(EFE+SID2), Proton, , , , , , , , , ,  

01. SiC; 2. Si

Bias 1: 400V; Bias 2: -100 V; SiC with Cividec

Entry  Sun Nov 7 18:50:31 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 1, , 800, VI, , 30 spills, Good, , , , , , , none,  

Start: 06:33 O(kHz)

Entry  Sun Nov 7 18:52:10 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 2, , 800, V, , 30 spills, Good, , , , , , , none,  

Start: 06:40 O(100kHz)

Entry  Sun Nov 7 18:52:29 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 3, , 800, VII, , 30 spills, Good, , , , , , , none,  

Start: 06:46 O(MHz)

Entry  Sun Nov 7 18:52:55 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 4, , 252.7, I(EFE+SID0), , 30 spills, Good, , , , , , , none,  

Start: 06:54 O(MHz)

Entry  Sun Nov 7 18:53:46 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 5, , 145.4, I(EFE+SID0), , 30 spills, Good, , , , , , , none,  

Start: 07:01 O(MHz)

Entry  Sun Nov 7 18:55:52 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 6, , 62.4, I(EFE+SID0), , 30 spills, Good, , , , , , , none,  

Start: 07:07 O(MHz)

Entry  Sun Nov 7 18:57:03 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 7, , 252.7, II(BETA+EFE), , 30 spills, Good, , , , , , , none,  

Start: 07:13 O(100kHz)

Entry  Sun Nov 7 18:59:12 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 8, , 145.4, II(BETA+EFE), , 30 spills, Good, , , , , , , none,  

Start: 07:20 O(100kHz)

Entry  Sun Nov 7 18:59:28 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 9, , 62.4, II(BETA+EFE), , 30 spills, Good, , , , , , , none,  

Start: 07:26 O(100kHz)

Entry  Sun Nov 7 18:59:43 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 10, , 252.7, III(EFE+SID2), , 30 spills, Good, , , , , , , none,  

Start: 07:33 O(kHz)

Entry  Sun Nov 7 19:00:20 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 11, , 145.4, III(EFE+SID2), , 30 spills, Good, , , , , , , none,  

Start: 07:39 O(kHz)

Entry  Sun Nov 7 19:00:36 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 12, , 62.4, III(EFE+SID2), , 30 spills, Good, , , , , , , none,  

Start: 07:44 O(kHz)

Entry  Sun Nov 7 19:00:54 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 13, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 08:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

coarse run (to find Bragg range

Entry  Sun Nov 7 19:02:25 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 14, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop"

Entry  Sun Nov 7 19:04:10 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 15, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run
"Accumalte Charge"

Entry  Sun Nov 7 19:05:15 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 16, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)

1cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement