Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 15 of 18  Not logged in ELOG logo
ID Date Authordown Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle Text Attachments
  238   Sun Jun 20 19:54:37 2021 Felix Ulrich-PurHADES sandwich TOF11HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0TB 20.6.21

Start 15:55
5cm Phantom thickness
  
  239   Sun Jun 20 19:55:47 2021 Felix Ulrich-PurHADES sandwich TOF reference run12HADES-LGADs100.4I(EFE+SID0)Proton Good      none0TB 20.6.21

Start 16:46
0cm Phantom thickness
  
  240   Sun Jun 20 19:58:31 2021 Felix Ulrich-PurHADES sandwich TOF13HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0TB 20.6.21

Start 17:27
3cm Phantom thickness
  
  241   Sun Jun 20 19:59:31 2021 Felix Ulrich-PurHADES sandwich TOF14HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0TB 20.6.21

Start 18:03
1cm Phantom thickness
  
  242   Sun Jun 20 20:00:05 2021 Felix Ulrich-PurHADES testrun 800MeV16HADES-LGADs800VIIProton Good      none0TB 20.6.21

Start 19:19
Mean rate O(MHz)
  
  243   Sun Jun 20 20:02:03 2021 Felix Ulrich-PurHADES sandwich TOF15HADES-LGADs+PMMAslabs100.4I(EFE+SID0)Proton Good      PMMA0TB 20.6.21

Start 18:45
2cm Phantom thickness
  
  244   Sun Jun 20 20:05:38 2021 Felix Ulrich-PurHADES testrun with increased rate 800MeV17HADES-LGADs800nominalProton Good  10   none0TB 20.6.21

Start 20:10
Mean rate O(200MHz)
  
  273   Sun Nov 7 18:50:31 2021 Felix Ulrich-PurLow flux test 7.11.211 800VI 30 spillsGood      none Start: 06:33 O(kHz)   
  274   Sun Nov 7 18:52:10 2021 Felix Ulrich-PurLow flux test 7.11.212 800V 30 spillsGood      none Start: 06:40 O(100kHz)   
  275   Sun Nov 7 18:52:29 2021 Felix Ulrich-PurLow flux test 7.11.213 800VII 30 spillsGood      none Start: 06:46 O(MHz)   
  276   Sun Nov 7 18:52:55 2021 Felix Ulrich-PurLow flux test 7.11.214 252.7I(EFE+SID0) 30 spillsGood      none Start: 06:54 O(MHz)   
  277   Sun Nov 7 18:53:46 2021 Felix Ulrich-PurLow flux test 7.11.215 145.4I(EFE+SID0) 30 spillsGood      none Start: 07:01 O(MHz)   
  278   Sun Nov 7 18:55:52 2021 Felix Ulrich-PurLow flux test 7.11.216 62.4I(EFE+SID0) 30 spillsGood      none Start: 07:07 O(MHz)   
  279   Sun Nov 7 18:57:03 2021 Felix Ulrich-PurLow flux test 7.11.217 252.7II(BETA+EFE) 30 spillsGood      none Start: 07:13 O(100kHz)   
  280   Sun Nov 7 18:59:12 2021 Felix Ulrich-PurLow flux test 7.11.218 145.4II(BETA+EFE) 30 spillsGood      none Start: 07:20 O(100kHz)   
  281   Sun Nov 7 18:59:28 2021 Felix Ulrich-PurLow flux test 7.11.219 62.4II(BETA+EFE) 30 spillsGood      none Start: 07:26 O(100kHz)   
  282   Sun Nov 7 18:59:43 2021 Felix Ulrich-PurLow flux test 7.11.2110 252.7III(EFE+SID2) 30 spillsGood      none Start: 07:33 O(kHz)   
  283   Sun Nov 7 19:00:20 2021 Felix Ulrich-PurLow flux test 7.11.2111 145.4III(EFE+SID2) 30 spillsGood      none Start: 07:39 O(kHz)   
  284   Sun Nov 7 19:00:36 2021 Felix Ulrich-PurLow flux test 7.11.2112 62.4III(EFE+SID2) 30 spillsGood      none Start: 07:44 O(kHz)   
  285   Sun Nov 7 19:00:54 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2113 175.3nominal  Good  10   none Start: 08:30
WET measurement of PMMA slabs also
used for TOF-CT (GSI)
  
ELOG V3.1.5-fc6679b