  MedAustron 2021, Page 15 of 18  Not logged in ELOG logo
Entry  Sun Nov 7 18:52:29 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 3, , 800, VII, , 30 spills, Good, , , , , , , none,  

Start: 06:46 O(MHz)

Entry  Sun Nov 7 18:52:55 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 4, , 252.7, I(EFE+SID0), , 30 spills, Good, , , , , , , none,  

Start: 06:54 O(MHz)

Entry  Sun Nov 7 18:53:46 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 5, , 145.4, I(EFE+SID0), , 30 spills, Good, , , , , , , none,  

Start: 07:01 O(MHz)

Entry  Sun Nov 7 18:55:52 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 6, , 62.4, I(EFE+SID0), , 30 spills, Good, , , , , , , none,  

Start: 07:07 O(MHz)

Entry  Sun Nov 7 18:57:03 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 7, , 252.7, II(BETA+EFE), , 30 spills, Good, , , , , , , none,  

Start: 07:13 O(100kHz)

Entry  Sun Nov 7 18:59:12 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 8, , 145.4, II(BETA+EFE), , 30 spills, Good, , , , , , , none,  

Start: 07:20 O(100kHz)

Entry  Sun Nov 7 18:59:28 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 9, , 62.4, II(BETA+EFE), , 30 spills, Good, , , , , , , none,  

Start: 07:26 O(100kHz)

Entry  Sun Nov 7 18:59:43 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 10, , 252.7, III(EFE+SID2), , 30 spills, Good, , , , , , , none,  

Start: 07:33 O(kHz)

Entry  Sun Nov 7 19:00:20 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 11, , 145.4, III(EFE+SID2), , 30 spills, Good, , , , , , , none,  

Start: 07:39 O(kHz)

Entry  Sun Nov 7 19:00:36 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 12, , 62.4, III(EFE+SID2), , 30 spills, Good, , , , , , , none,  

Start: 07:44 O(kHz)

Entry  Sun Nov 7 19:00:54 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 13, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 08:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

coarse run (to find Bragg range

Entry  Sun Nov 7 19:02:25 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 14, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop"

Entry  Sun Nov 7 19:04:10 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 15, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run
"Accumalte Charge"

Entry  Sun Nov 7 19:05:15 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 16, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)

1cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

Entry  Sun Nov 7 19:06:06 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 17, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 10:06
WET measurement of PMMA slabs also used for TOF-CT (GSI)

2cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

Entry  Sun Nov 7 19:06:26 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 18, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 10:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

3cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

Entry  Sun Nov 7 19:06:40 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 19, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 11:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

4cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

Entry  Sun Nov 7 19:06:58 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 20, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

Entry  Sun Nov 7 19:07:31 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 21, , 194.3, nominal, , , Good, , , 10, , , , none,  

Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

coarse run

Entry  Sun Nov 7 19:08:47 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 22, , 194.3, nominal, , , Good, , , 10, , , , none,  

Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"

more detailed measurement