Sun Nov 7 18:59:28 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 9, , 62.4, II(BETA+EFE), , 30 spills, Good, , , , , , , none,
|
Start: 07:26 O(100kHz) |
Sun Nov 7 18:59:43 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 10, , 252.7, III(EFE+SID2), , 30 spills, Good, , , , , , , none,
|
Start: 07:33 O(kHz) |
Sun Nov 7 19:00:20 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 11, , 145.4, III(EFE+SID2), , 30 spills, Good, , , , , , , none,
|
Start: 07:39 O(kHz) |
Sun Nov 7 19:00:36 2021, Felix Ulrich-Pur, Low flux test 7.11.21, 12, , 62.4, III(EFE+SID2), , 30 spills, Good, , , , , , , none,
|
Start: 07:44 O(kHz) |
Sun Nov 7 19:00:54 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 13, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 08:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)
coarse run (to find Bragg range |
Sun Nov 7 19:02:25 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 14, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)
reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop" |
Sun Nov 7 19:04:10 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 15, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)
reference run
"Accumalte Charge" |
Sun Nov 7 19:05:15 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 16, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)
1cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
Sun Nov 7 19:06:06 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 17, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 10:06
WET measurement of PMMA slabs also used for TOF-CT (GSI)
2cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
Sun Nov 7 19:06:26 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 18, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 10:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)
3cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
Sun Nov 7 19:06:40 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 19, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 11:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)
4cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
Sun Nov 7 19:06:58 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 20, , 175.3, nominal, , , Good, , , 10, , , , none,
|
Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)
5cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
Sun Nov 7 19:07:31 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 21, , 194.3, nominal, , , Good, , , 10, , , , none,
|
Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)
5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"
coarse run |
Sun Nov 7 19:08:47 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 22, , 194.3, nominal, , , Good, , , 10, , , , none,
|
Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)
5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"
more detailed measurement |
Sun Nov 7 19:09:50 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 24, , 252.7, II(BETA+EFE), Proton, , Good, , , , , , , none,
|
Start: 13:58
Alignment run without phantom |
Sun Nov 7 19:10:31 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 25, , 145.4, II(BETA+EFE), Proton, 40e6, Good, , , , , , , none,
|
Start: 14:04
Reference run without phantom |
Sun Nov 7 19:11:24 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 26, Drehtisch, 145.4, II(BETA+EFE), Proton, 60e6, Good, , , , , , , Alu, 0
|
Start: 15:19
1 cm Alu stair phantom on rotary table (0deg--> always 1cm Al in beam) |
Sun Nov 7 19:12:57 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 27, Drehtisch, 145.4, II(BETA+EFE), Proton, 60e6, Good, , , , , , , Alu, 90
|
Start: 16:40
1 cm Alu stair phantom on rotary table (90deg--> 0.2-1cm Alu) |
Sun Nov 7 19:13:36 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 28, Drehtisch, 100.4, II(BETA+EFE), Proton, 60e6, Good, , , , , , , Alu, 90
|
Start: 18:00
1 cm Alu stair phantom on rotary table (90deg) |
Sun Nov 7 19:28:49 2021, Felix Ulrich-Pur, Fluence loss meas 7.11.21, 29, Drehtisch, 100.4, II(BETA+EFE), Proton, 60e6, Good, , , , , , , Alu, 0
|
Start: 19:28
1 cm Alu stair phantom on rotary table (0deg) |
|