Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 15 of 18  Not logged in ELOG logo
Entry  Sat Feb 27 18:43:35 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 15, SiC+Si+RaMon, 100.4, III(EFE+SID2), , , Good, , , , , , , ,  

Start 11:09

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Tue Mar 16 15:04:52 2021, Patrick Sieberer, Pad Sensoren, 15, , 145.4, II(BETA+EFE), Proton, , Good, , , , , , , none,  

Start: 11:26
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Tue Mar 16 15:16:01 2021, Patrick Sieberer, MPW2 Analog output, 15, MPW2+Picoscope, 62.4, I(EFE+SID0), Proton, , Good, , , , , , , ,  

3er Koinzidenz
Pix 06, 33, 34

Entry  Wed May 12 08:56:37 2021, Felix Ulrich-Pur, ABS 0deg fluence loss, 15, Drehtisch, 145.4, II(BETA+EFE), Proton, , Good, , , , , , , ABS, 0 

TB 24.4.21

corrected trigger position for fluence loss radiography

0deg (1cm ABS)

Entry  Sun Jun 20 20:02:03 2021, Felix Ulrich-Pur, HADES sandwich TOF, 15, HADES-LGADs+PMMAslabs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , PMMA, 0 

TB 20.6.21

Start 18:45
2cm Phantom thickness
Mean rate O(MHz)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9

last sensor did not work

Entry  Thu Oct 7 10:57:31 2021, Philipp Gaggl, Pad Sensoren, 15, SiC+Si, 62.4, II(BETA+EFE), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V
Trigger SiC

Entry  Sun Nov 7 19:04:10 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 15, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run
"Accumalte Charge"

Entry  Sat Oct 8 10:16:45 2022, Patrick Sieberer, ramon + tracker + DUT, 15, RD50-MPW3, 252.7, , , , Good, lowflux low, , , , , , ,  

ASIC: TH 1300
BEAM OFF, for TH check

Entry  Sun Jan 10 06:51:12 2021, Maximilian Tomaschek, Lowflux recommissioning, 14, Ramon+Tracker, 100.4, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate, now Beta 10%

Entry  Sat Feb 27 18:43:12 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 14, SiC+Si+RaMon, 145.4, III(EFE+SID2), , , Good, , , , , , , ,  

Start 10:47

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Tue Mar 16 15:04:21 2021, Patrick Sieberer, Pad Sensoren, 14, , 62.4, II(BETA+EFE), Proton, , Good, , , , , , , none,  

Start: 11:14
Range Shifter Out, Filter 1 IN, Filter 2 IN

Entry  Tue Mar 16 15:15:12 2021, Patrick Sieberer, MPW2 Analog output, 14, MPW2+Picoscope, 252.7, I(EFE+SID0), Proton, , Good, , , , , , , ,  

3er Koinzidenz
Pix 06, 33, 34
retry for Run 11 (wrong picodata format)

Entry  Sun Jun 20 19:59:31 2021, Felix Ulrich-Pur, HADES sandwich TOF, 14, HADES-LGADs+PMMAslabs, 100.4, I(EFE+SID0), Proton, , Good, , , , , , , PMMA, 0 

TB 20.6.21

Start 18:03
1cm Phantom thickness
Mean rate O(MHz)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9

last sensor stopped working
 

Entry  Thu Oct 7 10:56:59 2021, Philipp Gaggl, Pad Sensoren, 14, SiC+Si, 62.4, II(BETA+EFE), Proton, , Unknown, , , , , , , ,  

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V
Repeat of run 13

Entry  Sun Nov 7 19:02:25 2021, Felix Ulrich-Pur, Peakfinder WET meas 7.11.21, 14, , 175.3, nominal, , , Good, , , 10, , , , none,  

Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop"

Entry  Sat Oct 8 10:11:27 2022, Patrick Sieberer, ramon + tracker + DUT, 14, RD50-MPW3, 252.7, , , , Good, lowflux low, , , , , , ,  

ASIC: TH 1300

Entry  Wed Jan 20 17:15:32 2021, Felix Ulrich-Pur, Lowflux recommissioning, 13, Ramon+Tracker, 145.4, , , 30 spills, , 10%, , 10, 1, , 2, ,  

Rate

Entry  Sat Feb 27 18:42:13 2021, Felix Ulrich-Pur, Waveforms SiC+Si, 13, SiC+Si+RaMon, 252.7, III(EFE+SID2), , , Good, , , , , , , ,  

Start 10:38
no signal in SiC

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x = 8
y = 68

Entry  Tue Mar 16 15:03:23 2021, Patrick Sieberer, Pad Sensoren, 13, , 252.7, I(EFE+SID0), Proton, , Good, , , , , , , none,  

Start: 10:31
Range Shifter Out, Filter 1 IN, Filter 2 IN
10:57 went inside to restart the Trenz NUC PC + FPGA

Entry  Tue Mar 16 15:14:28 2021, Patrick Sieberer, MPW2 Analog output, 13, MPW2+Picoscope, 83, I(EFE+SID0), Proton, , Good, , , , , , , ,  

3er Koinzidenz
Pix 06, 33, 34

ELOG V3.1.5-fc6679b