ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Events |
Data |
Beam Betatron |
Beam Chopper |
Beam Degrader |
Beam EFE |
Beam Orb |
Beam QuadScan |
PhantomType |
PhantomAngle |
89
|
Sat Feb 27 18:43:35 2021 |
Felix Ulrich-Pur | Waveforms SiC+Si | 15 | SiC+Si+RaMon | 100.4 | III(EFE+SID2) | | | Good | | | | | | | | |
Start 11:09
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x = 8
y = 68 |
160
|
Tue Mar 16 15:04:52 2021 |
Patrick Sieberer | Pad Sensoren | 15 | | 145.4 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:26
Range Shifter Out, Filter 1 IN, Filter 2 IN |
178
|
Tue Mar 16 15:16:01 2021 |
Patrick Sieberer | MPW2 Analog output | 15 | MPW2+Picoscope | 62.4 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |
226
|
Wed May 12 08:56:37 2021 |
Felix Ulrich-Pur | ABS 0deg fluence loss | 15 | Drehtisch | 145.4 | II(BETA+EFE) | Proton | | Good | | | | | | | ABS | 0 |
TB 24.4.21
corrected trigger position for fluence loss radiography
0deg (1cm ABS) |
243
|
Sun Jun 20 20:02:03 2021 |
Felix Ulrich-Pur | HADES sandwich TOF | 15 | HADES-LGADs+PMMAslabs | 100.4 | I(EFE+SID0) | Proton | | Good | | | | | | | PMMA | 0 |
TB 20.6.21
Start 18:45
2cm Phantom thickness
Mean rate O(MHz)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
last sensor did not work |
250
|
Thu Oct 7 10:57:31 2021 |
Philipp Gaggl | Pad Sensoren | 15 | SiC+Si | 62.4 | II(BETA+EFE) | Proton | | Unknown | | | | | | | | |
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V
Trigger SiC |
287
|
Sun Nov 7 19:04:10 2021 |
Felix Ulrich-Pur | Peakfinder WET meas 7.11.21 | 15 | | 175.3 | nominal | | | Good | | | 10 | | | | none | |
Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)
reference run
"Accumalte Charge" |
325
|
Sat Oct 8 10:16:45 2022 |
Patrick Sieberer | ramon + tracker + DUT | 15 | RD50-MPW3 | 252.7 | | | | Good | lowflux low | | | | | | | |
ASIC: TH 1300
BEAM OFF, for TH check |
12
|
Sun Jan 10 06:51:12 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 14 | Ramon+Tracker | 100.4 | | | 30 spills | | 10% | | 10 | 1 | | 2 | | |
Rate, now Beta 10% |
88
|
Sat Feb 27 18:43:12 2021 |
Felix Ulrich-Pur | Waveforms SiC+Si | 14 | SiC+Si+RaMon | 145.4 | III(EFE+SID2) | | | Good | | | | | | | | |
Start 10:47
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x = 8
y = 68 |
159
|
Tue Mar 16 15:04:21 2021 |
Patrick Sieberer | Pad Sensoren | 14 | | 62.4 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:14
Range Shifter Out, Filter 1 IN, Filter 2 IN |
177
|
Tue Mar 16 15:15:12 2021 |
Patrick Sieberer | MPW2 Analog output | 14 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34
retry for Run 11 (wrong picodata format) |
241
|
Sun Jun 20 19:59:31 2021 |
Felix Ulrich-Pur | HADES sandwich TOF | 14 | HADES-LGADs+PMMAslabs | 100.4 | I(EFE+SID0) | Proton | | Good | | | | | | | PMMA | 0 |
TB 20.6.21
Start 18:03
1cm Phantom thickness
Mean rate O(MHz)
for live TOF estimation: TDC3,channel 9 - TDC2,channel9
last sensor stopped working
|
249
|
Thu Oct 7 10:56:59 2021 |
Philipp Gaggl | Pad Sensoren | 14 | SiC+Si | 62.4 | II(BETA+EFE) | Proton | | Unknown | | | | | | | | |
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 400 V
Repeat of run 13 |
286
|
Sun Nov 7 19:02:25 2021 |
Felix Ulrich-Pur | Peakfinder WET meas 7.11.21 | 14 | | 175.3 | nominal | | | Good | | | 10 | | | | none | |
Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)
reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop" |
324
|
Sat Oct 8 10:11:27 2022 |
Patrick Sieberer | ramon + tracker + DUT | 14 | RD50-MPW3 | 252.7 | | | | Good | lowflux low | | | | | | | |
ASIC: TH 1300 |
48
|
Wed Jan 20 17:15:32 2021 |
Felix Ulrich-Pur | Lowflux recommissioning | 13 | Ramon+Tracker | 145.4 | | | 30 spills | | 10% | | 10 | 1 | | 2 | | |
Rate |
87
|
Sat Feb 27 18:42:13 2021 |
Felix Ulrich-Pur | Waveforms SiC+Si | 13 | SiC+Si+RaMon | 252.7 | III(EFE+SID2) | | | Good | | | | | | | | |
Start 10:38
no signal in SiC
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x = 8
y = 68 |
158
|
Tue Mar 16 15:03:23 2021 |
Patrick Sieberer | Pad Sensoren | 13 | | 252.7 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 10:31
Range Shifter Out, Filter 1 IN, Filter 2 IN
10:57 went inside to restart the Trenz NUC PC + FPGA |
176
|
Tue Mar 16 15:14:28 2021 |
Patrick Sieberer | MPW2 Analog output | 13 | MPW2+Picoscope | 83 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |