Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024 testbeam-MA2025
  MedAustron 2021, Page 14 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Datadown Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  328   Sat Oct 8 10:29:27 2022 Christian Irmlerramon + tracker + DUT18RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1400
BEAM OFF, for TH check

  329   Sat Oct 8 10:30:38 2022 Christian Irmlerramon + tracker + DUT19RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1300 again for verificationn - still too many noise hits
BEAM OFF, for TH check

  17   Sun Jan 10 07:02:15 2021 Maximilian TomaschekLowflux recommissioning19Ramon+Tracker194.3  30 spillsCrap  101 0  

Rate, Beta nominal, ERROR tracker  -> reset TLU

  20   Sun Jan 10 07:05:52 2021 Maximilian TomaschekLowflux recommissioning23Ramon+Tracker100.4  30 spillsCrap  101 0  

Rate, Beta nominal, suddenly no tracker events

  21   Sun Jan 10 07:14:54 2021 Maximilian TomaschekLowflux recommissioning24Ramon+Tracker83  30 spillsCrap  101 0  

Rate, Beta nominal, no tracker data

  22   Sun Jan 10 07:17:44 2021 Maximilian TomaschekLowflux recommissioning25Ramon+Tracker62.4  30 spillsCrap  101 0  

Rate, Beta nominal, no tracker data

  54   Wed Jan 20 17:31:04 2021 Felix Ulrich-PurLowflux p800 commissioning61Ramon+Tracker800  30 spillsCrap10%60%10106dB   

wrong degrader setting
setting IV
 

  77   Sat Feb 27 09:28:07 2021 Felix Ulrich-PurRate verification2SiC+Si+RaMon252.7III(EFE+SID2)  Crap        

Start 06:47
rate only 10Hz, stopped run, room request and rewired trigger.

NOTE: Problem was caused by operators: Optics were not set correctly after ramping up energy from 62.4 to 252.7, not trigger cable

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

  101   Sat Feb 27 19:09:26 2021 Felix Ulrich-PurHV Scan DSSD+SiC59SiC+DSSD tracker100.4II(BETA+EFE)Proton Crap        

Start 17:14:
Final MT=1, final BSY length =500 (2kHz), Trigger latency 41 optimal
HV 200 V, accidentally ZS instead of RAW

  102   Sat Feb 27 19:10:14 2021 Felix Ulrich-PurHV Scan DSSD+SiC60SiC+DSSD tracker100.4II(BETA+EFE)Proton Crap        

Start 17:30:
Final MT=1, final BSY length =500 (2kHz), Trigger latency 41 optimal
accidentally ZS instead of RAW

HV 300V

  103   Sat Feb 27 19:12:19 2021 Felix Ulrich-PurHV Scan DSSD+SiC61SiC+DSSD tracker100.4II(BETA+EFE)Proton Crap        

Start 17:44:
Final MT=1, final BSY length =500 (2kHz), Trigger latency 41 optimal
accidentally ZS instead of RAW

HV 400V

  117   Tue Mar 2 14:42:56 2021 Patrick SiebererMPW2 Tracking75MPW2+tracker252.7I(EFE+SID0)Proton Crap        

Start xx:xx:

Tracker speed test: 2MHz internal Trigger from TLU -> works.

  118   Tue Mar 2 14:45:04 2021 Patrick SiebererMPW2 Tracking76MPW2+tracker252.7I(EFE+SID0)Proton Crap        

Start xx:xx:

Tracker speed test: 4MHz internal Trigger from TLU -> works.
Tracker Setting: max_trigger=1 and trigger_busy=25. This gives ~20kHz eventrate.

  119   Tue Mar 2 14:46:49 2021 Patrick SiebererMPW2 Tracking77-82MPW2+tracker252.7I(EFE+SID0)Proton Crap        

Start 22:23 (Run79), 22:30, 22:37, 22:43 

Synchronization: Playing around with trgger_busy (range 25-500) This slows down Eventrate, but does not solve our issue of not being able to count all overflows. (This depends on the ratio of events hitting the MPW2 only, NOT on the overall busy rate)

  120   Tue Mar 2 15:30:11 2021 Patrick SiebererMPW2 Tracking83MPW2+tracker252.7I(EFE+SID0)Proton100kCrap        

Start 22:55
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 25
3 Koinzidenz TLU und 3er Koinzidenz Messung am MPW

  121   Tue Mar 2 15:32:52 2021 Patrick SiebererMPW2 Tracking84MPW2+tracker252.7I(EFE+SID0)Proton30kCrap        

Start 23:21
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 2er Koinzidenz Messmodus am MPW
Conclusion: Slowing down Tracker does not help (seen before)

  127   Tue Mar 2 15:43:01 2021 Patrick SiebererMPW2 Tracking90MPW2+tracker252.7I(EFE+SID0)Proton300kCrap        

Start 00:34
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW
Testen neue Software: Triggernummer von 2er Koinzidenz modus, Daten von 3er Koinzidenz modus
Forgot to restart Producer

  130   Tue Mar 2 15:47:32 2021 Patrick SiebererMPW2 Tracking93MPW2+tracker252.7I(EFE+SID0)Proton Crap        

Start 00:xx
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW
Davor: Neue local runs am Tracker (...TLU_92.xml) -> Ab hier verwendet
Run for testing beam only

  131   Tue Mar 2 15:49:03 2021 Patrick SiebererMPW2 Tracking94MPW2+tracker252.7I(EFE+SID0)Proton155kCrap        

Start 01:08
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW
 

  137   Tue Mar 2 15:54:04 2021 Patrick SiebererMPW2 Analog output100MPW2+Picoscope252.7I(EFE+SID0)Proton0Crap        

Setting switched to analog curve forms (CaR Board ADC + picoscope) - first 2 tracker planes moved outside beam
Threshold MPW2: 960mV, Pixel R3 C3
3 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW

Crap run, MPW did not send data
 

ELOG V3.1.5-fc6679b