Entry  Sat Oct 8 10:29:27 2022, Christian Irmler, ramon + tracker + DUT, 18, RD50-MPW3, 252.7, , , , Good, lowflux low, , , , , , ,  

ASIC: TH 1400
BEAM OFF, for TH check

Entry  Sat Oct 8 10:30:38 2022, Christian Irmler, ramon + tracker + DUT, 19, RD50-MPW3, 252.7, , , , Good, lowflux low, , , , , , ,  

ASIC: TH 1300 again for verificationn - still too many noise hits
BEAM OFF, for TH check

Entry  Sun Jan 10 07:02:15 2021, Maximilian Tomaschek, Lowflux recommissioning, 19, Ramon+Tracker, 194.3, , , 30 spills, Crap, , , 10, 1, , 0, ,  

Rate, Beta nominal, ERROR tracker  -> reset TLU

Entry  Sun Jan 10 07:05:52 2021, Maximilian Tomaschek, Lowflux recommissioning, 23, Ramon+Tracker, 100.4, , , 30 spills, Crap, , , 10, 1, , 0, ,  

Rate, Beta nominal, suddenly no tracker events

Entry  Sun Jan 10 07:14:54 2021, Maximilian Tomaschek, Lowflux recommissioning, 24, Ramon+Tracker, 83, , , 30 spills, Crap, , , 10, 1, , 0, ,  

Rate, Beta nominal, no tracker data

Entry  Sun Jan 10 07:17:44 2021, Maximilian Tomaschek, Lowflux recommissioning, 25, Ramon+Tracker, 62.4, , , 30 spills, Crap, , , 10, 1, , 0, ,  

Rate, Beta nominal, no tracker data

Entry  Wed Jan 20 17:31:04 2021, Felix Ulrich-Pur, Lowflux p800 commissioning, 61, Ramon+Tracker, 800, , , 30 spills, Crap, 10%, 60%, 10, 10, 6dB, , ,  

wrong degrader setting
setting IV
 

Entry  Sat Feb 27 09:28:07 2021, Felix Ulrich-Pur, Rate verification, 2, SiC+Si+RaMon, 252.7, III(EFE+SID2), , , Crap, , , , , , , ,  

Start 06:47
rate only 10Hz, stopped run, room request and rewired trigger.

NOTE: Problem was caused by operators: Optics were not set correctly after ramping up energy from 62.4 to 252.7, not trigger cable

 

channel 1 : Si upstream
channel 2: SiC downstream

400 V Bias

Referenz: 2.475V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1

position:

x: 0
y: 0 

Entry  Sat Feb 27 19:09:26 2021, Felix Ulrich-Pur, HV Scan DSSD+SiC, 59, SiC+DSSD tracker, 100.4, II(BETA+EFE), Proton, , Crap, , , , , , , ,  

Start 17:14:
Final MT=1, final BSY length =500 (2kHz), Trigger latency 41 optimal
HV 200 V, accidentally ZS instead of RAW

Entry  Sat Feb 27 19:10:14 2021, Felix Ulrich-Pur, HV Scan DSSD+SiC, 60, SiC+DSSD tracker, 100.4, II(BETA+EFE), Proton, , Crap, , , , , , , ,  

Start 17:30:
Final MT=1, final BSY length =500 (2kHz), Trigger latency 41 optimal
accidentally ZS instead of RAW

HV 300V

Entry  Sat Feb 27 19:12:19 2021, Felix Ulrich-Pur, HV Scan DSSD+SiC, 61, SiC+DSSD tracker, 100.4, II(BETA+EFE), Proton, , Crap, , , , , , , ,  

Start 17:44:
Final MT=1, final BSY length =500 (2kHz), Trigger latency 41 optimal
accidentally ZS instead of RAW

HV 400V

Entry  Tue Mar 2 14:42:56 2021, Patrick Sieberer, MPW2 Tracking, 75, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

Start xx:xx:

Tracker speed test: 2MHz internal Trigger from TLU -> works.

Entry  Tue Mar 2 14:45:04 2021, Patrick Sieberer, MPW2 Tracking, 76, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

Start xx:xx:

Tracker speed test: 4MHz internal Trigger from TLU -> works.
Tracker Setting: max_trigger=1 and trigger_busy=25. This gives ~20kHz eventrate.

Entry  Tue Mar 2 14:46:49 2021, Patrick Sieberer, MPW2 Tracking, 77-82, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

Start 22:23 (Run79), 22:30, 22:37, 22:43 

Synchronization: Playing around with trgger_busy (range 25-500) This slows down Eventrate, but does not solve our issue of not being able to count all overflows. (This depends on the ratio of events hitting the MPW2 only, NOT on the overall busy rate)

Entry  Tue Mar 2 15:30:11 2021, Patrick Sieberer, MPW2 Tracking, 83, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 100k, Crap, , , , , , , ,  

Start 22:55
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 25
3 Koinzidenz TLU und 3er Koinzidenz Messung am MPW

Entry  Tue Mar 2 15:32:52 2021, Patrick Sieberer, MPW2 Tracking, 84, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 30k, Crap, , , , , , , ,  

Start 23:21
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 2er Koinzidenz Messmodus am MPW
Conclusion: Slowing down Tracker does not help (seen before)

Entry  Tue Mar 2 15:43:01 2021, Patrick Sieberer, MPW2 Tracking, 90, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 300k, Crap, , , , , , , ,  

Start 00:34
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und 3er Koinzidenz Messmodus am MPW
Testen neue Software: Triggernummer von 2er Koinzidenz modus, Daten von 3er Koinzidenz modus
Forgot to restart Producer

Entry  Tue Mar 2 15:47:32 2021, Patrick Sieberer, MPW2 Tracking, 93, MPW2+tracker, 252.7, I(EFE+SID0), Proton, , Crap, , , , , , , ,  

Start 00:xx
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW
Davor: Neue local runs am Tracker (...TLU_92.xml) -> Ab hier verwendet
Run for testing beam only

Entry  Tue Mar 2 15:49:03 2021, Patrick Sieberer, MPW2 Tracking, 94, MPW2+tracker, 252.7, I(EFE+SID0), Proton, 155k, Crap, , , , , , , ,  

Start 01:08
Threshold MPW2: 960mV, Pixel R1 C1
MaxTrigger: 1, Trigger-busy: 500
2 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW
 

Entry  Tue Mar 2 15:54:04 2021, Patrick Sieberer, MPW2 Analog output, 100, MPW2+Picoscope, 252.7, I(EFE+SID0), Proton, 0, Crap, , , , , , , ,  

Setting switched to analog curve forms (CaR Board ADC + picoscope) - first 2 tracker planes moved outside beam
Threshold MPW2: 960mV, Pixel R3 C3
3 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW

Crap run, MPW did not send data
 