Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 13 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energydown Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  11   Sun Jan 10 06:50:45 2021 Maximilian TomaschekLowflux recommissioning12Ramon+Tracker175.3  30 spills 10% 101 2  

Rate

  18   Sun Jan 10 07:03:56 2021 Maximilian TomaschekLowflux recommissioning20Ramon+Tracker175.3  30 spillsGood  101 0  

Rate, Beta nominal

  27   Sun Jan 10 07:22:59 2021 Maximilian TomaschekLowflux recommissioning31Ramon+Tracker175.3  10 spills 1e6 eventsGood10% 101    

Spotsize

  34   Sun Jan 10 07:26:31 2021 Maximilian TomaschekLowflux recommissioning38Ramon+Tracker175.3  7 spills 1e6 eventsGood  101 0  

Spotsize

  41   Sun Jan 10 07:32:00 2021 Maximilian TomaschekLowflux recommissioning50Ramon+Tracker175.3  40 spills 350k eventsGood10% 101 2  

Spotsize

  114   Sat Feb 27 23:45:38 2021 Christian IrmlerE Scan DSSD+SiC72SiC+DSSD tracker175.3II(BETA+EFE)Proton5E5Good        

Start 19:59:
Final MT=1, final BSY length =600 (2kHz), Trigger latency 41 optimal

HV 500V

  142   Tue Mar 2 16:00:54 2021 Patrick SiebererMPW2 Analog output105MPW2+Picoscope175.3I(EFE+SID0)Proton1kGood        

MPW2 ANALOG
Threshold MPW2: 960mV, Pixel R3 C3, Pixel R3 C4, Pixel R0 C1. Pixel R0 C6
3 Koinzidenz TLU und Hybrid Modus (2er und 3er Koinzidenz) am MPW

1k ADC curves per pixel
 

  179   Tue Mar 16 15:16:24 2021 Patrick SiebererMPW2 Analog output16MPW2+Picoscope175.3I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34

  285   Sun Nov 7 19:00:54 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2113 175.3nominal  Good  10   none 

Start: 08:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

coarse run (to find Bragg range

  286   Sun Nov 7 19:02:25 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2114 175.3nominal  Good  10   none 

Start: 08:55
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run (with Arduino Spill Start/Stop logic)
fringes in Bragg peak (trigger not optimal (maybe too much latency with Arduino))--> next measurement with "Accumalte Charge" instead of "Spill Start/Stop"

  287   Sun Nov 7 19:04:10 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2115 175.3nominal  Good  10   none 

Start: 09:14
WET measurement of PMMA slabs also used for TOF-CT (GSI)

reference run
"Accumalte Charge"

  288   Sun Nov 7 19:05:15 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2116 175.3nominal  Good  10   none 

Start: 09:38
WET measurement of PMMA slabs also used for TOF-CT (GSI)

1cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  289   Sun Nov 7 19:06:06 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2117 175.3nominal  Good  10   none 

Start: 10:06
WET measurement of PMMA slabs also used for TOF-CT (GSI)

2cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  290   Sun Nov 7 19:06:26 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2118 175.3nominal  Good  10   none 

Start: 10:30
WET measurement of PMMA slabs also used for TOF-CT (GSI)

3cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  291   Sun Nov 7 19:06:40 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2119 175.3nominal  Good  10   none 

Start: 11:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)

4cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  292   Sun Nov 7 19:06:58 2021 Felix Ulrich-PurPeakfinder WET meas 7.11.2120 175.3nominal  Good  10   none 

Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)

5cm PMMA
"Accumalte Charge"

PMMA was activated. Had to wait ~10-15min after measurement

  19   Sun Jan 10 07:04:21 2021 Maximilian TomaschekLowflux recommissioning21Ramon+Tracker145.4  15 spillsGood  101 0  

Rate, Beta nominal

  28   Sun Jan 10 07:23:25 2021 Maximilian TomaschekLowflux recommissioning32Ramon+Tracker145.4  10 spills 1e6 eventsGood10%  10    

Spotsize

  35   Sun Jan 10 07:26:42 2021 Maximilian TomaschekLowflux recommissioning39Ramon+Tracker145.4  7 spills 1e6 eventsGood  101 0  

Spotsize

  42   Sun Jan 10 07:32:11 2021 Maximilian TomaschekLowflux recommissioning51Ramon+Tracker145.4  40 spills 350k eventsGood10% 101 2  

Spotsize

ELOG V3.1.5-fc6679b