167
|
Tue Mar 16 15:09:04 2021 |
Patrick Sieberer | Pad Sensoren | 22 | | 800 | V | Proton | | Good | | | | | | | none | |
Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA |
186
|
Tue Mar 16 15:18:31 2021 |
Patrick Sieberer | MPW2 Analog output | 22 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Crap | | | | | | | | |
3er Koinzidenz
for Beam |
257
|
Thu Oct 7 11:01:53 2021 |
Philipp Gaggl | Pad Sensoren | 22 | SiC+Si | 62.4 | I(EFE+SID0) | Proton | | Unknown | | | | | | | | |
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 600 V |
294
|
Sun Nov 7 19:08:47 2021 |
Felix Ulrich-Pur | Peakfinder WET meas 7.11.21 | 22 | | 194.3 | nominal | | | Good | | | 10 | | | | none | |
Start: 12:00
WET measurement of PMMA slabs also used for TOF-CT (GSI)
5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"
more detailed measurement |
332
|
Sat Oct 8 10:37:45 2022 |
Christian Irmler | ramon + tracker + DUT | 22 | RD50-MPW3 | 252.7 | | | | Unknown | lowflux low | | | | | | | |
ASIC: TH 1330
BEAM OFF, for TH check
only few (1 or 2) pixel fire at a low frequency.
Will use this threshold from now on.
|
19
|
Sun Jan 10 07:04:21 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 21 | Ramon+Tracker | 145.4 | | | 15 spills | Good | | | 10 | 1 | | 0 | | |
Rate, Beta nominal |
95
|
Sat Feb 27 18:56:11 2021 |
Felix Ulrich-Pur | Waveforms SiC+Si | 21 | SiC+Si+RaMon | 252.7 | nominal | Proton | | Good | | | 50 | | | | | |
Start 13:56
Degrader 50
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x = 8
y = 68
|
166
|
Tue Mar 16 15:07:56 2021 |
Patrick Sieberer | Pad Sensoren | 21 | | 100.4 | III(EFE+SID2) | Proton | | Good | | | | | | | none | |
Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated |
185
|
Tue Mar 16 15:18:23 2021 |
Patrick Sieberer | MPW2 Analog output | 21 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Crap | | | | | | | | |
3er Koinzidenz
for Beam |
256
|
Thu Oct 7 11:01:19 2021 |
Philipp Gaggl | Pad Sensoren | 21 | SiC+Si | 62.4 | I(EFE+SID0) | Proton | | Unknown | | | | | | | | |
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 800 V |
293
|
Sun Nov 7 19:07:31 2021 |
Felix Ulrich-Pur | Peakfinder WET meas 7.11.21 | 21 | | 194.3 | nominal | | | Good | | | 10 | | | | none | |
Start: 11:44
WET measurement of PMMA slabs also used for TOF-CT (GSI)
5cm PMMA. higher energy for Felix Feichtinger
"Accumalte Charge"
coarse run |
331
|
Sat Oct 8 10:35:23 2022 |
Christian Irmler | ramon + tracker + DUT | 21 | RD50-MPW3 | 252.7 | | | | Crap | lowflux low | | | | | | | |
ASIC: TH 1350
BEAM OFF, for TH check
no noise hits
|
18
|
Sun Jan 10 07:03:56 2021 |
Maximilian Tomaschek | Lowflux recommissioning | 20 | Ramon+Tracker | 175.3 | | | 30 spills | Good | | | 10 | 1 | | 0 | | |
Rate, Beta nominal |
94
|
Sat Feb 27 18:52:12 2021 |
Felix Ulrich-Pur | Waveforms SiC+Si | 20 | SiC+Si+RaMon | 252.7 | nominal | Proton | | Good | | | 10 | | | | | |
Start 13:42
Degrader 10
channel 1 : Si upstream
channel 2: SiC downstream
400 V Bias
Referenz: 2.100 V channel 2, 0-Level: 2.310V channel 2
Referenz: 2.477V channel 1, 0-Level: 2.315V channel 1
position:
x = 8
y = 68 |
165
|
Tue Mar 16 15:07:06 2021 |
Patrick Sieberer | Pad Sensoren | 20 | | 100.4 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 12:25
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance of both sensors to 100 uA |
183
|
Tue Mar 16 15:17:58 2021 |
Patrick Sieberer | MPW2 Analog output | 20 | MPW2+Picoscope | 800 | VII | Proton | | Crap | | | | | | | | |
3er Koinzidenz
for Beam |
184
|
Tue Mar 16 15:18:12 2021 |
Patrick Sieberer | MPW2 Analog output | 20 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Crap | | | | | | | | |
3er Koinzidenz
for Beam |
255
|
Thu Oct 7 11:00:33 2021 |
Philipp Gaggl | Pad Sensoren | 20 | SiC+Si | 62.4 | I(EFE+SID0) | Proton | | Unknown | | | | | | | | |
beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V |
292
|
Sun Nov 7 19:06:58 2021 |
Felix Ulrich-Pur | Peakfinder WET meas 7.11.21 | 20 | | 175.3 | nominal | | | Good | | | 10 | | | | none | |
Start: 11:24
WET measurement of PMMA slabs also used for TOF-CT (GSI)
5cm PMMA
"Accumalte Charge"
PMMA was activated. Had to wait ~10-15min after measurement |
330
|
Sat Oct 8 10:32:44 2022 |
Christian Irmler | ramon + tracker + DUT | 20 | RD50-MPW3 | 252.7 | | | | Crap | lowflux low | | | | | | | |
ASIC: TH 1350
BEAM OFF, for TH check
MPW3 monitor not connected --> invalid |