Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 10 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Numberdown DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  3   Sun Jan 10 06:33:22 2021 Maximilian TomaschekLowflux recommissioning3Ramon+Tracker175.3  30 spills 10% 101    

Rate

  148   Tue Mar 16 14:54:40 2021 Patrick SiebererPad Sensoren3 252.7III(EFE+SID2)Proton Good      none 

Start: 07:00
Range Shifter Out, Filter 1 IN, Filter 2 IN
Scintillators in front

  217   Wed May 12 08:48:19 2021 Felix Ulrich-PurAlu 0deg3Drehtisch100.4II(BETA+EFE)Proton Good      Alu0

TB 24.4.21
 

0deg (1cm Alu) Profil von Stiege

  229   Sun Jun 20 19:33:06 2021 Felix Ulrich-PurHADES testrun with increased rate 100.4MeV3HADES-LGADs100.4I(EFE+SID0)Proton Good      none0

TB 19.6.21

Start 11:21
paused beam at 13:36
15:40-16:20 ECR source fail--downtime

Mean rate O(MHz)

  275   Sun Nov 7 18:52:29 2021 Felix Ulrich-PurLow flux test 7.11.213 800VII 30 spillsGood      none 

Start: 06:46 O(MHz)

  304   Sun Nov 21 14:05:18 2021 Simon WaidComparison SiC, Si, Si LGAD and Diamond3 62.4I(EFE+SID0)Proton10000         

Bias voltage SiC: 800

Bias voltage Si LGAD: -100

From a beam perspective the SiC detector was the first target, on oscilloscope channel 4, the Si LGAD was the second target connected to oscilloscope channel 1.

Triggering source was the Si LGAD detector. The SiC detector was most probably defective.

Data was stored on the HiBPM-Osci-2 NUC under c:\measurements

  308   Sat Dec 11 17:47:52 2021 Felix Ulrich-PurAlignment run3DSSD-Tracker800VProton Good      none 

Fluence loss measurement 11.12.2021

 

 

  314   Sat Oct 8 07:28:42 2022 Christian Irmlertestrun ramon + tracker + DUT3RD50-MPW3800   Unknownlowflux high       

Tracker latency lat=42

  263   Thu Oct 7 11:08:16 2021 Philipp GagglPad Sensoren29SiC+Si213.4 Carbon Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

  300   Sun Nov 7 19:28:49 2021 Felix Ulrich-PurFluence loss meas 7.11.2129Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu0

Start: 19:28

1 cm Alu stair phantom on rotary table (0deg)

  339   Sat Oct 8 11:30:26 2022 Patrick Siebererramon + tracker + DUT29RD50-MPW3100.4   Unknownlowflux high       

ASIC: TH 1350
BEAM OFF

 

 

 

 

  25   Sun Jan 10 07:19:17 2021 Maximilian TomaschekLowflux recommissioning28Ramon+Tracker252.7  10 spills 1e6 eventsGood10% 101    

Spotsize 

  262   Thu Oct 7 11:07:08 2021 Philipp GagglPad Sensoren28SiC+Si402.8 Carbon Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

  299   Sun Nov 7 19:13:36 2021 Felix Ulrich-PurFluence loss meas 7.11.2128Drehtisch100.4II(BETA+EFE)Proton60e6Good      Alu90

Start: 18:00

1 cm Alu stair phantom on rotary table (90deg)

  338   Sat Oct 8 11:12:32 2022 Christian Irmlerramon + tracker + DUT28RD50-MPW3100.4   Unknownlowflux high       

ASIC: TH 1310
BEAM OFF

 

 

 

 

  24   Sun Jan 10 07:19:03 2021 Maximilian TomaschekLowflux recommissioning27Ramon+Tracker   30 spillsGood        

Spotsize test, nach power cycle

  172   Tue Mar 16 15:11:34 2021 Patrick SiebererPad Sensoren27 252.7nominalProton Good  100   none 

Start: 14:28
Range Shifter Out, Filter 1 IN, Filter 2 IN
Power supply of si-sensor went into compliance, therefore the compliance value was set to 100 uA again
Ende 14:35

  261   Thu Oct 7 11:03:37 2021 Philipp GagglPad Sensoren27SiC+Si120 Carbon Unknown  10     

beamtime on 18.09.2021
CH1: SiC
CH3: Si
Bias_Si: -100 V
Bias_SiC: 1100 V

  298   Sun Nov 7 19:12:57 2021 Felix Ulrich-PurFluence loss meas 7.11.2127Drehtisch145.4II(BETA+EFE)Proton60e6Good      Alu90

Start: 16:40

1 cm Alu stair phantom on rotary table (90deg--> 0.2-1cm Alu)

  337   Sat Oct 8 11:12:05 2022 Patrick Siebererramon + tracker + DUT27RD50-MPW3100.4   Unknownlowflux high       

ASIC: TH 1310 seems to be okay
BEAM ON all included

 

 

 

 

ELOG V3.1.5-fc6679b