Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 10 of 18  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degraderdown Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  153   Tue Mar 16 14:57:41 2021 Patrick SiebererPad Sensoren8 62.4I(EFE+SID0)Proton Good      none 

Start: 08:20
Range Shifter Out, Filter 1 IN, Filter 2 IN

  154   Tue Mar 16 14:58:37 2021 Patrick SiebererPad Sensoren9 145.4I(EFE+SID0)Proton Good      none 

Start: 08:34
Range Shifter Out, Filter 1 IN, Filter 2 IN
After that run: Downtime 8:40-10:09

  155   Tue Mar 16 14:59:18 2021 Patrick SiebererPad Sensoren10 145.4I(EFE+SID0)Proton Good      none 

Start: 10:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Interrupt run at 10:11 -> trying to deactivate filter from the beam room -> didn't work

  156   Tue Mar 16 15:00:37 2021 Patrick SiebererPad Sensoren11 145.4I(EFE+SID0)Proton Good      none 

Start: 10:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restarting run with the same settings

  157   Tue Mar 16 15:03:04 2021 Patrick SiebererPad Sensoren12 194.3I(EFE+SID0)Proton Good      none 

Start: 10:24
Range Shifter Out, Filter 1 IN, Filter 2 IN

  158   Tue Mar 16 15:03:23 2021 Patrick SiebererPad Sensoren13 252.7I(EFE+SID0)Proton Good      none 

Start: 10:31
Range Shifter Out, Filter 1 IN, Filter 2 IN
10:57 went inside to restart the Trenz NUC PC + FPGA

  159   Tue Mar 16 15:04:21 2021 Patrick SiebererPad Sensoren14 62.4II(BETA+EFE)Proton Good      none 

Start: 11:14
Range Shifter Out, Filter 1 IN, Filter 2 IN

  160   Tue Mar 16 15:04:52 2021 Patrick SiebererPad Sensoren15 145.4II(BETA+EFE)Proton Good      none 

Start: 11:26
Range Shifter Out, Filter 1 IN, Filter 2 IN

  161   Tue Mar 16 15:05:08 2021 Patrick SiebererPad Sensoren16 100.4II(BETA+EFE)Proton Good      none 

Start: 11:38
Range Shifter Out, Filter 1 IN, Filter 2 IN

  162   Tue Mar 16 15:05:24 2021 Patrick SiebererPad Sensoren17 194.3II(BETA+EFE)Proton Good      none 

Start: 11:46
Range Shifter Out, Filter 1 IN, Filter 2 IN

  163   Tue Mar 16 15:05:40 2021 Patrick SiebererPad Sensoren18 252.7II(BETA+EFE)Proton Good      none 

Start: 11:57
Range Shifter Out, Filter 1 IN, Filter 2 IN
Lost beam at 12:15

  164   Tue Mar 16 15:06:13 2021 Patrick SiebererPad Sensoren19 252.7II(BETA+EFE)Proton Good      none 

Start: 12:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restart run with same settings

  165   Tue Mar 16 15:07:06 2021 Patrick SiebererPad Sensoren20 100.4I(EFE+SID0)Proton Good      none 

Start: 12:25
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance of both sensors to 100 uA

  166   Tue Mar 16 15:07:56 2021 Patrick SiebererPad Sensoren21 100.4III(EFE+SID2)Proton Good      none 

Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated

  167   Tue Mar 16 15:09:04 2021 Patrick SiebererPad Sensoren22 800VProton Good      none 

Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA

  168   Tue Mar 16 15:09:33 2021 Patrick SiebererPad Sensoren23 800VIIProton Good      none 

Start: 13:36
Range Shifter Out, Filter 1 IN, Filter 2 IN

  173   Tue Mar 16 15:12:04 2021 Patrick SiebererMPW2 Analog output10MPW2+Picoscope252.7I(EFE+SID0)Proton Crap        

3er Koinzidenz
Pix 06, 33, 34

  174   Tue Mar 16 15:13:34 2021 Patrick SiebererMPW2 Analog output11MPW2+Picoscope252.7I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34

  175   Tue Mar 16 15:13:58 2021 Patrick SiebererMPW2 Analog output12MPW2+Picoscope252.7I(EFE+SID0)Proton Good        

2er Koinzidenz
Pix 06, 33, 34
Ratenmessunge fuer spaeteres Tracking

  176   Tue Mar 16 15:14:28 2021 Patrick SiebererMPW2 Analog output13MPW2+Picoscope83I(EFE+SID0)Proton Good        

3er Koinzidenz
Pix 06, 33, 34

ELOG V3.1.5-fc6679b