ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Events |
Data |
Beam Betatron |
Beam Chopper |
Beam Degrader |
Beam EFE |
Beam Orb |
Beam QuadScan |
PhantomType |
PhantomAngle |
153
|
Tue Mar 16 14:57:41 2021 |
Patrick Sieberer | Pad Sensoren | 8 | | 62.4 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 08:20
Range Shifter Out, Filter 1 IN, Filter 2 IN |
154
|
Tue Mar 16 14:58:37 2021 |
Patrick Sieberer | Pad Sensoren | 9 | | 145.4 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 08:34
Range Shifter Out, Filter 1 IN, Filter 2 IN
After that run: Downtime 8:40-10:09 |
155
|
Tue Mar 16 14:59:18 2021 |
Patrick Sieberer | Pad Sensoren | 10 | | 145.4 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 10:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Interrupt run at 10:11 -> trying to deactivate filter from the beam room -> didn't work |
156
|
Tue Mar 16 15:00:37 2021 |
Patrick Sieberer | Pad Sensoren | 11 | | 145.4 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 10:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restarting run with the same settings |
157
|
Tue Mar 16 15:03:04 2021 |
Patrick Sieberer | Pad Sensoren | 12 | | 194.3 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 10:24
Range Shifter Out, Filter 1 IN, Filter 2 IN |
158
|
Tue Mar 16 15:03:23 2021 |
Patrick Sieberer | Pad Sensoren | 13 | | 252.7 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 10:31
Range Shifter Out, Filter 1 IN, Filter 2 IN
10:57 went inside to restart the Trenz NUC PC + FPGA |
159
|
Tue Mar 16 15:04:21 2021 |
Patrick Sieberer | Pad Sensoren | 14 | | 62.4 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:14
Range Shifter Out, Filter 1 IN, Filter 2 IN |
160
|
Tue Mar 16 15:04:52 2021 |
Patrick Sieberer | Pad Sensoren | 15 | | 145.4 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:26
Range Shifter Out, Filter 1 IN, Filter 2 IN |
161
|
Tue Mar 16 15:05:08 2021 |
Patrick Sieberer | Pad Sensoren | 16 | | 100.4 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:38
Range Shifter Out, Filter 1 IN, Filter 2 IN |
162
|
Tue Mar 16 15:05:24 2021 |
Patrick Sieberer | Pad Sensoren | 17 | | 194.3 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:46
Range Shifter Out, Filter 1 IN, Filter 2 IN |
163
|
Tue Mar 16 15:05:40 2021 |
Patrick Sieberer | Pad Sensoren | 18 | | 252.7 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 11:57
Range Shifter Out, Filter 1 IN, Filter 2 IN
Lost beam at 12:15 |
164
|
Tue Mar 16 15:06:13 2021 |
Patrick Sieberer | Pad Sensoren | 19 | | 252.7 | II(BETA+EFE) | Proton | | Good | | | | | | | none | |
Start: 12:18
Range Shifter Out, Filter 1 IN, Filter 2 IN
Restart run with same settings |
165
|
Tue Mar 16 15:07:06 2021 |
Patrick Sieberer | Pad Sensoren | 20 | | 100.4 | I(EFE+SID0) | Proton | | Good | | | | | | | none | |
Start: 12:25
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance of both sensors to 100 uA |
166
|
Tue Mar 16 15:07:56 2021 |
Patrick Sieberer | Pad Sensoren | 21 | | 100.4 | III(EFE+SID2) | Proton | | Good | | | | | | | none | |
Start: 12:41
Range Shifter Out, Filter 1 IN, Filter 2 IN
12:53 went inside to test if sensors are activated |
167
|
Tue Mar 16 15:09:04 2021 |
Patrick Sieberer | Pad Sensoren | 22 | | 800 | V | Proton | | Good | | | | | | | none | |
Start: 13:09
Range Shifter Out, Filter 1 IN, Filter 2 IN
Changed compliance values back to 30 uA |
168
|
Tue Mar 16 15:09:33 2021 |
Patrick Sieberer | Pad Sensoren | 23 | | 800 | VII | Proton | | Good | | | | | | | none | |
Start: 13:36
Range Shifter Out, Filter 1 IN, Filter 2 IN |
173
|
Tue Mar 16 15:12:04 2021 |
Patrick Sieberer | MPW2 Analog output | 10 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Crap | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |
174
|
Tue Mar 16 15:13:34 2021 |
Patrick Sieberer | MPW2 Analog output | 11 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |
175
|
Tue Mar 16 15:13:58 2021 |
Patrick Sieberer | MPW2 Analog output | 12 | MPW2+Picoscope | 252.7 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
2er Koinzidenz
Pix 06, 33, 34
Ratenmessunge fuer spaeteres Tracking |
176
|
Tue Mar 16 15:14:28 2021 |
Patrick Sieberer | MPW2 Analog output | 13 | MPW2+Picoscope | 83 | I(EFE+SID0) | Proton | | Good | | | | | | | | |
3er Koinzidenz
Pix 06, 33, 34 |