Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2020, Page 7 of 15  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngledown Events Data Text Attachments
  21   Sun May 10 19:39:34 2020 Felix Ulrich-PurBeam Diamond+pCT6 500V19Diamond + DSSD-pCT662.4nonenone EFE SID2none 101031 Diamond+pCT6
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
 01-000019.root-cogLocations_5.1.1.0-Empirics.png01-000019.root-cogLocations_5.1.1.1-Empirics.png 
  22   Sun May 10 20:26:25 2020 Felix Ulrich-PurBeam+Diamond 500V20Diamond100.4nonenone EFE SID2none 103032 Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
  
  23   Sun May 10 20:41:43 2020 Felix Ulrich-PurBeam+Diamond 500V21Diamond194.3nonenone EFE SID2none 150960 Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
  
  24   Sun May 10 22:04:51 2020 Christian IrmlerBeam+Diamond 500V22Diamond252.7nonenone EFE SID2none 221012 Diamond
Dia HV = +/- 250V

run taken instead of 800MeV -->
  
  25   Sun May 10 22:21:11 2020 Felix Ulrich-PurCalibration Tracker+Diamond 500V24Diamond + DSSD tracker252.7nonenone    none   Diamond+Tracker
Dia HV = +/- 250V

 
  
  26   Fri Jun 12 23:10:40 2020 Felix Ulrich-PurCalibration TERA MPV 2001TERA-Cal800106020106dB none   Setting 4

was stopped, cause timout setting
was not adjusted to spill structure
  
  27   Fri Jun 12 23:47:07 2020 Felix Ulrich-PurCalibration TERA MPV 2002TERA-Cal800106020106dB none   Setting 4

slice R1 did not converge therofor
9 steps
  
  28   Sat Jun 13 00:01:43 2020 Felix Ulrich-PurCalibration TERA MPV 3003TERA-Cal800106020106dB none   Setting 4

 
  
  29   Sat Jun 13 00:14:44 2020 Felix Ulrich-PurCalibration TERA MPV 4004TERA-Cal800106020106dB none   Setting 4

stopped because one slice could
not be calibrated due to SW error
  
  30   Sat Jun 13 00:29:22 2020 Felix Ulrich-PurCalibration TERA MPV 4005TERA-Cal800106020106dB none   Setting 4

S9 did not converge run stopped

 
  
  31   Sat Jun 13 00:34:32 2020 Felix Ulrich-PurCalibration TERA MPV 4006TERA-Cal800106020106dB none   Setting 4

 
  
  32   Sat Jun 13 00:54:47 2020 Felix Ulrich-PurCalibration TERA MPV 3007TERA-Cal800106020106dB none   Setting 4

repeated 300, because of SW error
in previous run
  
  33   Sat Jun 13 01:07:52 2020 Felix Ulrich-PurCalibration TERA MPV 2008TERA-Cal800106020106dB none   Setting 4

repeated 200, because of SW error
in previous run
  
  34   Sat Jun 13 01:29:35 2020 Felix Ulrich-PurCalibration TERA MPV 6009TERA-Cal800106020106dB none   Setting 4

few slices did not converge ->
adapt range setting
  
  35   Sat Jun 13 01:51:17 2020 Felix Ulrich-PurCalibration TERA MPV 60010TERA-Cal800106020106dB none   Setting 4

few slices did not converge ->
adapted range setting
  
  36   Sat Jun 13 02:16:06 2020 Felix Ulrich-PurCalibration TERA Sr-90 Voltages11TERA-Cal800106020106dB none 60000 1Setting 4

used same voltages as calibrated
with Sr-90 (MPV 300)
  
  37   Sat Jun 13 02:16:43 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 200MPV12TERA-Cal100.4BETA  EFE SID2none 200000 Linearity Messung Gain 200MPV   
  38   Sat Jun 13 02:37:10 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 300MPV13TERA-Cal100.4BETA  EFE SID2none 200000 Linearity Messung Gain 300MPV   
  39   Sat Jun 13 02:41:54 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 400MPV14TERA-Cal100.4BETA  EFE SID2none 200000 Linearity Messung Gain 400MPV   
  40   Sat Jun 13 03:06:25 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 600MPV15TERA-Cal100.4BETA  EFE SID2none 200000 Linearity Messung Gain 600MPV error in
config file aborted
  
ELOG V3.1.5-fc6679b