Sat Jun 13 00:14:44 2020, Felix Ulrich-Pur, Calibration TERA MPV 400, 4, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,
|
Setting 4
stopped because one slice could not be calibrated due to SW error |
Sat Jun 13 00:29:22 2020, Felix Ulrich-Pur, Calibration TERA MPV 400, 5, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,
|
Setting 4
S9 did not converge run stopped
|
Sat Jun 13 00:34:32 2020, Felix Ulrich-Pur, Calibration TERA MPV 400, 6, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,
|
Setting 4
|
Sat Jun 13 00:01:43 2020, Felix Ulrich-Pur, Calibration TERA MPV 300, 3, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,
|
Setting 4
|
Sat Jun 13 00:54:47 2020, Felix Ulrich-Pur, Calibration TERA MPV 300, 7, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,
|
Setting 4
repeated 300, because of SW error in previous run
|
Fri Jun 12 23:10:40 2020, Felix Ulrich-Pur, Calibration TERA MPV 200, 1, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,
|
Setting 4
was stopped, cause timout setting was not adjusted to spill structure |
Fri Jun 12 23:47:07 2020, Felix Ulrich-Pur, Calibration TERA MPV 200, 2, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,
|
Setting 4
slice R1 did not converge therofor 9 steps |
Sat Jun 13 01:07:52 2020, Felix Ulrich-Pur, Calibration TERA MPV 200, 8, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,
|
Setting 4
repeated 200, because of SW error in previous run
|
Sun May 10 14:51:12 2020, Christian Irmler, Calibration Runs, 1, Diamond + DSSD tracker, Noise, , , , , , , none, , ,
|
ADC delay, FIR, ped, noise,cal with DSSD tracker + diamond
DSSD HV= +/- 50V
Dia HV = +/- 250V |
Fri Jun 19 19:22:10 2020, Felix Ulrich-Pur, Calibration Diamond,Silimond,pCT6+Diamand, 30, Diamond, , , , , , , , , , ,
|
300V-800V in 100V steps
xml files:
/mnt/data/xmls/local/pct_dia_01_diamond_800V_02-000030.xml |
Sun May 10 17:44:50 2020, Felix Ulrich-Pur, Calibration Diamond+pCT6 500V, 11, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,
|
Diamond+pCT6
Dia HV = +/- 250V
ADC, FIR, ped, noise, cal |
Sun May 10 17:38:55 2020, Felix Ulrich-Pur, Calibration Diamond+pCT6 400V, 10, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,
|
Diamond+pCT6
Dia HV = +/- 200V
ADC, FIR, ped, noise, cal |
Sun May 10 16:47:10 2020, Christian Irmler, Calibration Diamond 600V, 4, Diamond, 252.7, none, none, , , , , none, , ,
|
diamond only
Dia HV = +/- 300V
ADC, FIR, ped, noise, cal |
Sun May 10 16:44:46 2020, Christian Irmler, Calibration Diamond 500V, 3, Diamond, 252.7, none, none, , , , , none, , ,
|
diamond only
Dia HV = +/- 250V
ADC, FIR, ped, noise, cal |
Sun May 10 17:21:28 2020, Felix Ulrich-Pur, Calibration Diamond 400V, 9, Diamond, 252.7, none, none, , , , , none, , ,
|
Diamond only
Dia HV = +/- 200V
ADC, FIR, ped, noise, cal |
Sun May 10 17:16:58 2020, Christian Irmler, Calibration Diamond 300V, 8, Diamond, 252.7, none, none, , , , , none, , ,
|
Diamond only
Dia HV = +/- 150V
ADC, FIR, ped, noise, cal |
Sun May 10 17:01:42 2020, Christian Irmler, Calibration Diamond + pCT-6 600V, 6, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,
|
pCT-6 + diamond
DSSD HV = +/-50V
Dia HV = +/- 300V |
Sun May 10 17:14:00 2020, Christian Irmler, Calibration Diamond + pCT-6 300V, 7, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,
|
pCT-6 + diamond
DSSD HV = +/-50V
Dia HV = +/- 150V |
Sat Jul 4 04:06:58 2020, Felix Ulrich-Pur, Beta+EFE spot-size measurement, 14, Lynx+RaMon+Octavius+Film, 62.4, yes, , , yes, , , , , ,
|
tested 120+180s exposure time of Lynx |
Sat Jul 4 04:15:29 2020, Felix Ulrich-Pur, Beta+EFE spot-size measurement, 15, Lynx+RaMon+Octavius, 252.7, yes, , , yes, , , , , ,
|
tested 180s exposure time of Lynx |
|