Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2020, Page 6 of 15  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orbdown Beam QuadScan PhantomType PhantomAngle Events Data Text Attachments
  92   Fri Jun 19 19:22:10 2020 Felix Ulrich-PurCalibration Diamond,Silimond,pCT6+Diamand30Diamond           300V-800V in 100V steps

xml files:

  
  93   Sun Jun 21 05:31:37 2020 Felix Ulrich-PurSilimond31Diamond + DSSD trackerNoise          local run   
  104   Sun Jun 21 12:29:57 2020 Felix Ulrich-PurDiamond only 252.7MeV 700V42Diamond252.7   EFE SID2  113770 252.7 MeV global run

 

telescope shifted 6mm to the left
  
  105   Sun Jun 21 13:11:19 2020 Felix Ulrich-PurDiamond only 252.7MeV 500V43Diamond252.7   EFE SID2  101536 252.7 MeV global run

 

telescope shifted 6mm to the left
  
  106   Sun Jun 21 13:11:37 2020 Felix Ulrich-PurDiamond only 62.4MeV 700V44Diamond62.4   EFE SID2  100528 62.4MeV global run

 

telescope shifted 6mm to the left
  
  107   Sun Jun 21 13:54:57 2020 Felix Ulrich-PurDiamond only 252.7 MeV 500V45Diamond252.7   EFE SID0    252.7 MeV 4MHz flux text no spill structure 
in current visible

 
  
  108   Sun Jun 21 13:57:57 2020 Felix Ulrich-PurDiamond only 252.7 MeV 500V46Diamond252.7  10       252.7 MeV 400MHz flux test: spill structure 
in current visible

nominal flux degrader 10, random
  
  109   Sun Jun 21 14:16:41 2020 Felix Ulrich-PurDiamond only 252.7 MeV 800V47Diamond252.7   EFE SID2  118671 252.7 MeV lobal run

 

telescope shifted 6mm to the left
  
  110   Sun Jun 21 14:17:34 2020 Felix Ulrich-PurSilimond 500V48DiamondNoise          500 V run after high flux irradiation

 
  
  111   Sat Jul 4 03:58:14 2020 Felix Ulrich-PurEFE SID0 Energy measurement1Peakfinder100.4   yes SID0    3 spills per measurement point   
  112   Sat Jul 4 03:59:45 2020 Felix Ulrich-PurEFE SID0 Energy measurement2Peakfinder145.4   yes SID0    2 spills per measurement point   
  113   Sat Jul 4 04:00:05 2020 Felix Ulrich-PurEFE SID0 Energy measurement3Peakfinder62.4   yes SID0    1 spills per measurement point   
  114   Sat Jul 4 04:00:31 2020 Felix Ulrich-PurEFE SID0 Energy measurement4Peakfinder252.7   yes SID0    2 spills per measurement point   
  115   Sat Jul 4 04:00:58 2020 Felix Ulrich-PurEFE SID2 Energy measurement5Peakfinder252.7   yes SID2    6 spills per point -> no signal measurable
(always 0)
  
  116   Sat Jul 4 04:01:29 2020 Felix Ulrich-PurEFE SID2 Energy measurement6Peakfinder62.4   yes SID2    6 spills per point -> no signal measurable
(always 0)
  
  117   Sat Jul 4 04:02:17 2020 Felix Ulrich-PurEFE SID0 spot-size measurement7Lynx+RaMon+Octavius+Film62.4   yes SID0    11 min irradiation of film (spot visible)

tested 180,90 and 60s exposure
time of Lynx (saturated at >=90)
  
  118   Sat Jul 4 04:04:09 2020 Felix Ulrich-PurEFE SID0 spot-size measurement8Lynx+RaMon+Octavius252.7   yes SID0    tested 90,60 and 30s exposure time of Lynx   
  119   Sat Jul 4 04:04:53 2020 Felix Ulrich-PurEFE SID0 spot-size measurement9Lynx+RaMon+Octavius194.3   yes SID0    tested 90,60 and 30s exposure time of Lynx   
  120   Sat Jul 4 04:05:13 2020 Felix Ulrich-PurEFE SID0 spot-size measurement10Lynx+RaMon+Octavius145.4   yes SID0    tested 60 and 30s exposure time of Lynx   
  121   Sat Jul 4 04:05:32 2020 Felix Ulrich-PurEFE SID0 spot-size measurement11Lynx+RaMon+Octavius175.3   yes SID0    tested 30 and 20s exposure time of Lynx   
ELOG V3.1.5-fc6679b