Entry  Fri May 8 15:17:39 2020, Felix Ulrich-Pur, , , DSSD-Tracker, Noise, , , , , , , , , ,  
 
Entry  Sun May 10 13:43:49 2020, Christian Irmler, setup, 1, Diamond + DSSD tracker, , , , , , , , none, , ,  setup.jpg
 
Entry  Sun May 10 14:51:12 2020, Christian Irmler, Calibration Runs, 1, Diamond + DSSD tracker, Noise, , , , , , , none, , ,  
ADC delay, FIR, ped, noise,cal with DSSD tracker + diamond
DSSD HV= +/- 50V
Dia HV = +/- 250V
Entry  Sun May 10 15:26:33 2020, Christian Irmler, alignment, 1, Diamond + DSSD tracker, 252.7, none, none, , EFE, , SID2, none, , 75970,  8x
alignment run
DSSD HV = +/- 50V
Dia HV = +/- 250V
Entry  Sun May 10 15:58:42 2020, Christian Irmler, alignment, 2, Diamond + DSSD tracker, 252.7, none, none, , EFE, , SID2, none, , 42740,  8x
alignment run
DSSD HV = +/- 50V
Dia HV = +/- 250V
Entry  Sun May 10 16:44:46 2020, Christian Irmler, Calibration Diamond 500V, 3, Diamond, 252.7, none, none, , , , , none, , ,  
diamond only
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 16:47:10 2020, Christian Irmler, Calibration Diamond 600V, 4, Diamond, 252.7, none, none, , , , , none, , ,  
diamond only
Dia HV = +/- 300V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 16:47:49 2020, Christian Irmler, Beam Diamond 600V, 5, Diamond, 252.7, none, none, , EFE, , SID2, none, , 103286,  
diamond only
Dia HV = +/- 300V

pct_dia_01_diamond_600V_01-000005.xml
Entry  Sun May 10 17:01:42 2020, Christian Irmler, Calibration Diamond + pCT-6 600V, 6, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,  
pCT-6 + diamond

DSSD HV = +/-50V
Dia HV = +/- 300V
Entry  Sun May 10 17:14:00 2020, Christian Irmler, Calibration Diamond + pCT-6 300V, 7, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,  
pCT-6 + diamond

DSSD HV = +/-50V
Dia HV = +/- 150V
Entry  Sun May 10 17:16:58 2020, Christian Irmler, Calibration Diamond 300V, 8, Diamond, 252.7, none, none, , , , , none, , ,  
Diamond only
Dia HV = +/- 150V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 17:21:28 2020, Felix Ulrich-Pur, Calibration Diamond 400V, 9, Diamond, 252.7, none, none, , , , , none, , ,  
Diamond only
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 17:38:55 2020, Felix Ulrich-Pur, Calibration Diamond+pCT6 400V, 10, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,  
Diamond+pCT6
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 17:44:50 2020, Felix Ulrich-Pur, Calibration Diamond+pCT6 500V, 11, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,  
Diamond+pCT6
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 18:13:10 2020, Felix Ulrich-Pur, Beam Diamond 300V, 13, Diamond, 252.7, none, none, , EFE, , SID2, none, , 124099,  
Diamond+pCT6
Dia HV = +/- 150V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 18:29:01 2020, Felix Ulrich-Pur, Beam Diamond 400V, 14, Diamond, 252.7, none, none, , EFE, , SID2, none, , 103304,  
Diamond+pCT6
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 18:34:18 2020, Felix Ulrich-Pur, Beam Diamond 400V, 15, Diamond, 62.4, none, none, , EFE, , SID2, none, , 100868,  
Diamond+pCT6
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 18:55:45 2020, Felix Ulrich-Pur, Beam Diamond 300V, 16, Diamond, 62.4, none, none, , EFE, , SID2, none, , 104515,  
Diamond+pCT6
Dia HV = +/- 150V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 19:27:52 2020, Felix Ulrich-Pur, Beam Diamond 600V, 17, Diamond, 62.4, none, none, , EFE, , SID2, none, , 44667,  
Diamond+pCT6
Dia HV = +/- 300V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 19:28:36 2020, Felix Ulrich-Pur, Beam Diamond 600V, 18, Diamond, 62.4, none, none, , EFE, , SID2, none, , 62250,  
Diamond+pCT6
Dia HV = +/- 300V

ADC, FIR, ped, noise, cal
ELOG V3.1.5-fc6679b