ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Beam Betatron |
Beam Chopper |
Beam Degrader |
Beam EFE |
Beam Orb |
Beam QuadScan |
PhantomType |
PhantomAngle |
Events |
Data |
103
|
Sun Jun 21 10:47:23 2020 |
Felix Ulrich-Pur | Silimond 800MeV 500V | 41 | Diamond + DSSD tracker | 800 | 10 | 60 | 20 | 10 | 6dB | | | | 83304 | |
800 MeV global run (tracking effciency)
setting4
telescope shifted 6mm to the left (in beam direction)
|
Draft
|
Fri May 8 15:17:39 2020 |
Felix Ulrich-Pur | | | DSSD-Tracker | Noise | | | | | | | | | | |
|
2
|
Sun May 10 13:43:49 2020 |
Christian Irmler | setup | 1 | Diamond + DSSD tracker | | | | | | | | none | | | |
|
Attachment 1: setup.jpg
|
|
3
|
Sun May 10 14:51:12 2020 |
Christian Irmler | Calibration Runs | 1 | Diamond + DSSD tracker | Noise | | | | | | | none | | | |
ADC delay, FIR, ped, noise,cal with DSSD tracker + diamond
DSSD HV= +/- 50V
Dia HV = +/- 250V
diamond not yet pumped
calibration files: pct_dia_01_silimond_tb_01-000001.xml |
4
|
Sun May 10 15:26:33 2020 |
Christian Irmler | alignment | 1 | Diamond + DSSD tracker | 252.7 | none | none | | EFE | | SID2 | none | | 75970 | |
alignment run
DSSD HV = +/- 50V
Dia HV = +/- 250V
xml = pct_dia_01_silimond_beam_01-000001.xml
start: 15:00
stop: 15:56 |
Attachment 1: 01-000001.root-cogLocations_5.1.1.0-Empirics.png
|
|
Attachment 2: 01-000001.root-cogLocations_5.1.1.1-Empirics.png
|
|
Attachment 3: 01-000001.root-cogLocations_5.1.2.0-Empirics.png
|
|
Attachment 4: 01-000001.root-cogLocations_5.1.2.1-Empirics.png
|
|
Attachment 5: 01-000001.root-cogLocations_5.1.3.0-Empirics.png
|
|
Attachment 6: 01-000001.root-cogLocations_5.1.3.1-Empirics.png
|
|
Attachment 7: 01-000001.root-cogLocations_5.1.4.0-Empirics.png
|
|
Attachment 8: 01-000001.root-cogLocations_5.1.4.1-Empirics.png
|
|
5
|
Sun May 10 15:58:42 2020 |
Christian Irmler | alignment | 2 | Diamond + DSSD tracker | 252.7 | none | none | | EFE | | SID2 | none | | 42740 | |
alignment run
DSSD HV = +/- 50V
Dia HV = +/- 250V
xml = pct_dia_01_silimond_beam_01-000001.xml
after ~ 1h beam (pumping)
start: 15:58
stop: 16:26 |
Attachment 1: 01-000002.root-cogLocations_5.1.1.0-Empirics.png
|
|
Attachment 2: 01-000002.root-cogLocations_5.1.1.1-Empirics.png
|
|
Attachment 3: 01-000002.root-cogLocations_5.1.2.0-Empirics.png
|
|
Attachment 4: 01-000002.root-cogLocations_5.1.2.1-Empirics.png
|
|
Attachment 5: 01-000002.root-cogLocations_5.1.3.0-Empirics.png
|
|
Attachment 6: 01-000002.root-cogLocations_5.1.3.1-Empirics.png
|
|
Attachment 7: 01-000002.root-cogLocations_5.1.4.0-Empirics.png
|
|
Attachment 8: 01-000002.root-cogLocations_5.1.4.1-Empirics.png
|
|
6
|
Sun May 10 16:44:46 2020 |
Christian Irmler | Calibration Diamond 500V | 3 | Diamond | 252.7 | none | none | | | | | none | | | |
diamond only
Dia HV = +/- 250V
ADC, FIR, ped, noise, cal |
7
|
Sun May 10 16:47:10 2020 |
Christian Irmler | Calibration Diamond 600V | 4 | Diamond | 252.7 | none | none | | | | | none | | | |
diamond only
Dia HV = +/- 300V
ADC, FIR, ped, noise, cal |
8
|
Sun May 10 16:47:49 2020 |
Christian Irmler | Beam Diamond 600V | 5 | Diamond | 252.7 | none | none | | EFE | | SID2 | none | | 103286 | |
diamond only
Dia HV = +/- 300V
pct_dia_01_diamond_600V_01-000005.xml |
9
|
Sun May 10 17:01:42 2020 |
Christian Irmler | Calibration Diamond + pCT-6 600V | 6 | Diamond + DSSD-pCT6 | 252.7 | none | none | | | | | none | | | |
pCT-6 + diamond
DSSD HV = +/-50V
Dia HV = +/- 300V
ADC, FIR, ped, noise, cal |
10
|
Sun May 10 17:14:00 2020 |
Christian Irmler | Calibration Diamond + pCT-6 300V | 7 | Diamond + DSSD-pCT6 | 252.7 | none | none | | | | | none | | | |
pCT-6 + diamond
DSSD HV = +/-50V
Dia HV = +/- 150V
ADC, FIR, ped, noise, cal |
11
|
Sun May 10 17:16:58 2020 |
Christian Irmler | Calibration Diamond 300V | 8 | Diamond | 252.7 | none | none | | | | | none | | | |
Diamond only
Dia HV = +/- 150V
ADC, FIR, ped, noise, cal |
12
|
Sun May 10 17:21:28 2020 |
Felix Ulrich-Pur | Calibration Diamond 400V | 9 | Diamond | 252.7 | none | none | | | | | none | | | |
Diamond only
Dia HV = +/- 200V
ADC, FIR, ped, noise, cal |
13
|
Sun May 10 17:38:55 2020 |
Felix Ulrich-Pur | Calibration Diamond+pCT6 400V | 10 | Diamond + DSSD-pCT6 | 252.7 | none | none | | | | | none | | | |
Diamond+pCT6
Dia HV = +/- 200V
ADC, FIR, ped, noise, cal |
14
|
Sun May 10 17:44:50 2020 |
Felix Ulrich-Pur | Calibration Diamond+pCT6 500V | 11 | Diamond + DSSD-pCT6 | 252.7 | none | none | | | | | none | | | |
Diamond+pCT6
Dia HV = +/- 250V
ADC, FIR, ped, noise, cal |
15
|
Sun May 10 18:13:10 2020 |
Felix Ulrich-Pur | Beam Diamond 300V | 13 | Diamond | 252.7 | none | none | | EFE | | SID2 | none | | 124099 | |
Diamond+pCT6
Dia HV = +/- 150V
ADC, FIR, ped, noise, cal |
16
|
Sun May 10 18:29:01 2020 |
Felix Ulrich-Pur | Beam Diamond 400V | 14 | Diamond | 252.7 | none | none | | EFE | | SID2 | none | | 103304 | |
Diamond+pCT6
Dia HV = +/- 200V
ADC, FIR, ped, noise, cal |
17
|
Sun May 10 18:34:18 2020 |
Felix Ulrich-Pur | Beam Diamond 400V | 15 | Diamond | 62.4 | none | none | | EFE | | SID2 | none | | 100868 | |
Diamond+pCT6
Dia HV = +/- 200V
ADC, FIR, ped, noise, cal |
18
|
Sun May 10 18:55:45 2020 |
Felix Ulrich-Pur | Beam Diamond 300V | 16 | Diamond | 62.4 | none | none | | EFE | | SID2 | none | | 104515 | |
Diamond+pCT6
Dia HV = +/- 150V
ADC, FIR, ped, noise, cal |
19
|
Sun May 10 19:27:52 2020 |
Felix Ulrich-Pur | Beam Diamond 600V | 17 | Diamond | 62.4 | none | none | | EFE | | SID2 | none | | 44667 | |
Diamond+pCT6
Dia HV = +/- 300V
ADC, FIR, ped, noise, cal
unterbrochen, da TLU-ERROR |