  28   Sat Jun 13 00:01:43 2020 Felix Ulrich-PurCalibration TERA MPV 3003TERA-Cal800106020106dB none   

Setting 4

 

  29   Sat Jun 13 00:14:44 2020 Felix Ulrich-PurCalibration TERA MPV 4004TERA-Cal800106020106dB none   

Setting 4

stopped because one slice could not be calibrated due to SW error

  30   Sat Jun 13 00:29:22 2020 Felix Ulrich-PurCalibration TERA MPV 4005TERA-Cal800106020106dB none   

Setting 4

S9 did not converge run stopped

 

  31   Sat Jun 13 00:34:32 2020 Felix Ulrich-PurCalibration TERA MPV 4006TERA-Cal800106020106dB none   

Setting 4

 

  32   Sat Jun 13 00:54:47 2020 Felix Ulrich-PurCalibration TERA MPV 3007TERA-Cal800106020106dB none   

Setting 4

repeated 300, because of SW error in previous run

 

  33   Sat Jun 13 01:07:52 2020 Felix Ulrich-PurCalibration TERA MPV 2008TERA-Cal800106020106dB none   

Setting 4

repeated 200, because of SW error in previous run

 

  34   Sat Jun 13 01:29:35 2020 Felix Ulrich-PurCalibration TERA MPV 6009TERA-Cal800106020106dB none   

Setting 4

few slices did not converge -> adapt range setting

 

  35   Sat Jun 13 01:51:17 2020 Felix Ulrich-PurCalibration TERA MPV 60010TERA-Cal800106020106dB none   

Setting 4

few slices did not converge -> adapted range setting

q9 and p3 did not converge-->choose mean voltage of group

 

  36   Sat Jun 13 02:16:06 2020 Felix Ulrich-PurCalibration TERA Sr-90 Voltages11TERA-Cal800106020106dB none 60000 

1Setting 4

used same voltages as calibrated with Sr-90 (MPV 300)

 

  37   Sat Jun 13 02:16:43 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 200MPV12TERA-Cal100.4BETA  EFE SID2none 200000 

Linearity Messung Gain 200MPV

  38   Sat Jun 13 02:37:10 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 300MPV13TERA-Cal100.4BETA  EFE SID2none 200000 

Linearity Messung Gain 300MPV

  39   Sat Jun 13 02:41:54 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 400MPV14TERA-Cal100.4BETA  EFE SID2none 200000 

Linearity Messung Gain 400MPV

  40   Sat Jun 13 03:06:25 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 600MPV15TERA-Cal100.4BETA  EFE SID2none 200000 

Linearity Messung Gain 600MPV error in config file aborted

  41   Sat Jun 13 03:06:44 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 600MPV16TERA-Cal100.4BETA  EFE SID2none 200000 

Linearity Messung Gain 600MPV

  42   Sat Jun 13 03:06:58 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 300MPV17TERA-Cal100.4BETA  EFE SID2none 200000 

Linearity Messung Gain 300MPV previous voltages were not applied

  43   Sat Jun 13 03:08:25 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 400MPV18TERA-Cal100.4BETA  EFE SID2none 200000 

Linearity Messung Gain 400MPV previous voltages were not applied

  44   Sat Jun 13 03:08:39 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain Sr9019TERA-Cal100.4BETA  EFE SID2none 200000 

9Linearity Messung Gain Sr-90

Calibration from Lab not useful-> maybe different voltages if all slices are connected

  45   Sat Jun 13 04:03:29 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 20020TERA-Cal100.4BETA  EFE  none 200000 

Linearity Messung Gain 200 10e5 rate

  46   Sat Jun 13 04:04:16 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 30021TERA-Cal100.4BETA  EFE  none 200000 

Linearity Messung Gain 300 10e5 rate

  47   Sat Jun 13 04:04:38 2020 Felix Ulrich-PurLinearity measurement TERA 100.4 gain 40022TERA-Cal100.4BETA  EFE  none 200000 

Linearity Messung Gain 400 10e5 rate