Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2020, Page 2 of 15  Not logged in ELOG logo
Entry  Sun Jun 21 10:47:23 2020, Felix Ulrich-Pur, Silimond 800MeV 500V, 41, Diamond + DSSD tracker, 800, 10, 60, 20, 10, 6dB, , , , 83304,  

800 MeV global run (tracking effciency)
setting4

 

telescope shifted 6mm to the left (in beam direction)

 

Entry  Sat Nov 21 16:45:40 2020, Patrick Sieberer, 2020-11-21, 34, DSSD-Tracker, 800, 10, 60, 20, 10, , , none, , ,  

tracker local run

Entry  Sat Nov 21 16:47:54 2020, Patrick Sieberer, 2020-11-21, 35, RaMon, 800, 10, 60, 20, 10, , , none, , ,  

trigger counting

Entry  Sat Nov 21 16:48:46 2020, Patrick Sieberer, 2020-11-21, 36, RaMon, 800, 10, 60, 20, 10, , , none, , ,  Screenshot_from_2020-11-21_17-38-43.png

trigger counting

division oscilloscpe: 1V 400ns

Entry  Sat Nov 21 16:49:10 2020, Patrick Sieberer, 2020-11-21, 37, DSSD-Tracker, 800, 10, 60, 20, 10, , , none, , ,  

config test

Entry  Sat Nov 21 16:49:41 2020, Patrick Sieberer, 2020-11-21, 38, DSSD-Tracker, 800, 10, 60, 20, 10, , , none, , ca 750000,  

tracker alignment (diamond read out, but not in beam)

Entry  Sat Nov 21 16:50:20 2020, Patrick Sieberer, 2020-11-21, 39, DSSD-Tracker, 800, 10, 60, 20, 10, , , none, , 670000,  

tracker moved 1cm up and 1cm left
tracker alignment (diamond read out, but not in beam)
- this is the new alignment run

Entry  Sat Nov 21 17:15:31 2020, Patrick Sieberer, 2020-11-21, 40, Diamond + DSSD tracker, 800, 10, 60, 20, 10, , , none, , 8621000,  hitmap-68.pnghitmap-69.pnghitmap-70.pnghitmap-71.png

tracking

Edit Alex: Mir ist aufgefallen, dass in ein paar Events zwischen den Events 6900000 bis 7100000 ein Artefakt in der Verteilung der Cluster am Diamanten auftaucht, das wie Noise aussieht. Siehe Plots

Entry  Sat Nov 21 20:09:13 2020, Patrick Sieberer, 2020-11-21, 41, Diamond + DSSD tracker, 800, 10, 60, 20, 10, , , none, , -,  

inverse bias, local run

Entry  Sat Nov 21 20:16:35 2020, Patrick Sieberer, 2020-11-21, 42, Diamond + DSSD tracker, 800, 10, 60, 20, 10, , , none, , 550000,  

inverse bias, tracking, no hits in diamond seen

Entry  Sat Nov 21 20:32:27 2020, Patrick Sieberer, 2020-11-21, 43, Diamond + DSSD tracker, 800, 10, 60, 20, 10, , , none, , 495000, Crap 

inverse bias, tracking, crap because wrong polarity of APV channels

Entry  Sat Nov 21 20:43:36 2020, Patrick Sieberer, 2020-11-21, 44, Diamond + DSSD tracker, 800, 10, 60, 20, 10, , , none, , , Unknown 

local run, (with switched APV channels)

Due to invers bias, p- and n-side of diamond are also flipped!

Entry  Sat Nov 21 21:30:16 2020, Patrick Sieberer, 2020-11-21, 45, Diamond + DSSD tracker, 800, 10, 60, 20, 10, , , none, , 3900000, Unknown 

tracking, (with switched APV channels)

Due to invers bias, p- and n-side of diamond are also flipped!

Entry  Sun Jun 21 13:57:57 2020, Felix Ulrich-Pur, Diamond only 252.7 MeV 500V, 46, Diamond, 252.7, , , 10, , , , , , ,  

252.7 MeV 400MHz flux test: spill structure  in current visible

nominal flux degrader 10, random trigger

 

telescope shifted 6mm to the left (in beam direction)

 

Entry  Fri May 8 15:17:39 2020, Felix Ulrich-Pur, , , DSSD-Tracker, Noise, , , , , , , , , ,  
 
Entry  Sun May 10 13:43:49 2020, Christian Irmler, setup, 1, Diamond + DSSD tracker, , , , , , , , none, , ,  setup.jpg
 
Entry  Sun May 10 14:51:12 2020, Christian Irmler, Calibration Runs, 1, Diamond + DSSD tracker, Noise, , , , , , , none, , ,  

ADC delay, FIR, ped, noise,cal with DSSD tracker + diamond
DSSD HV= +/- 50V
Dia HV = +/- 250V

diamond not yet pumped

calibration files: pct_dia_01_silimond_tb_01-000001.xml

Entry  Sun May 10 15:26:33 2020, Christian Irmler, alignment, 1, Diamond + DSSD tracker, 252.7, none, none, , EFE, , SID2, none, , 75970,  8x

alignment run
DSSD HV = +/- 50V
Dia HV = +/- 250V
xml = pct_dia_01_silimond_beam_01-000001.xml

start: 15:00
stop: 15:56

Entry  Sun May 10 15:58:42 2020, Christian Irmler, alignment, 2, Diamond + DSSD tracker, 252.7, none, none, , EFE, , SID2, none, , 42740,  8x

alignment run
DSSD HV = +/- 50V
Dia HV = +/- 250V
xml = pct_dia_01_silimond_beam_01-000001.xml

after ~ 1h beam (pumping)

start: 15:58
stop:  16:26

Entry  Sun May 10 16:44:46 2020, Christian Irmler, Calibration Diamond 500V, 3, Diamond, 252.7, none, none, , , , , none, , ,  

diamond only
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal

ELOG V3.1.5-fc6679b