  MedAustron 2020, Page 2 of 15  Not logged in ELOG logo
Entry  Sun May 10 17:16:58 2020, Christian Irmler, Calibration Diamond 300V, 8, Diamond, 252.7, none, none, , , , , none, , ,  
Diamond only
Dia HV = +/- 150V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 17:21:28 2020, Felix Ulrich-Pur, Calibration Diamond 400V, 9, Diamond, 252.7, none, none, , , , , none, , ,  
Diamond only
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 17:38:55 2020, Felix Ulrich-Pur, Calibration Diamond+pCT6 400V, 10, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,  
Diamond+pCT6
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 17:44:50 2020, Felix Ulrich-Pur, Calibration Diamond+pCT6 500V, 11, Diamond + DSSD-pCT6, 252.7, none, none, , , , , none, , ,  
Diamond+pCT6
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 18:13:10 2020, Felix Ulrich-Pur, Beam Diamond 300V, 13, Diamond, 252.7, none, none, , EFE, , SID2, none, , 124099,  
Diamond+pCT6
Dia HV = +/- 150V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 18:29:01 2020, Felix Ulrich-Pur, Beam Diamond 400V, 14, Diamond, 252.7, none, none, , EFE, , SID2, none, , 103304,  
Diamond+pCT6
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 18:34:18 2020, Felix Ulrich-Pur, Beam Diamond 400V, 15, Diamond, 62.4, none, none, , EFE, , SID2, none, , 100868,  
Diamond+pCT6
Dia HV = +/- 200V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 18:55:45 2020, Felix Ulrich-Pur, Beam Diamond 300V, 16, Diamond, 62.4, none, none, , EFE, , SID2, none, , 104515,  
Diamond+pCT6
Dia HV = +/- 150V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 19:27:52 2020, Felix Ulrich-Pur, Beam Diamond 600V, 17, Diamond, 62.4, none, none, , EFE, , SID2, none, , 44667,  
Diamond+pCT6
Dia HV = +/- 300V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 19:28:36 2020, Felix Ulrich-Pur, Beam Diamond 600V, 18, Diamond, 62.4, none, none, , EFE, , SID2, none, , 62250,  
Diamond+pCT6
Dia HV = +/- 300V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 19:39:34 2020, Felix Ulrich-Pur, Beam Diamond+pCT6 500V, 19, Diamond + DSSD-pCT6, 62.4, none, none, , EFE, , SID2, none, , 101031,  01-000019.root-cogLocations_5.1.1.0-Empirics.png01-000019.root-cogLocations_5.1.1.1-Empirics.png
Diamond+pCT6
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 20:26:25 2020, Felix Ulrich-Pur, Beam+Diamond 500V, 20, Diamond, 100.4, none, none, , EFE, , SID2, none, , 103032,  
Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 20:41:43 2020, Felix Ulrich-Pur, Beam+Diamond 500V, 21, Diamond, 194.3, none, none, , EFE, , SID2, none, , 150960,  
Diamond
Dia HV = +/- 250V

ADC, FIR, ped, noise, cal
Entry  Sun May 10 22:04:51 2020, Christian Irmler, Beam+Diamond 500V, 22, Diamond, 252.7, none, none, , EFE, , SID2, none, , 221012,  
Diamond
Dia HV = +/- 250V

run taken instead of 800MeV --> beam parameters for 800 were not prepared
Entry  Sun May 10 22:21:11 2020, Felix Ulrich-Pur, Calibration Tracker+Diamond 500V, 24, Diamond + DSSD tracker, 252.7, none, none, , , , , none, , ,  
Diamond+Tracker
Dia HV = +/- 250V

 
Entry  Fri Jun 12 23:10:40 2020, Felix Ulrich-Pur, Calibration TERA MPV 200, 1, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

was stopped, cause timout setting was not adjusted to spill structure
Entry  Fri Jun 12 23:47:07 2020, Felix Ulrich-Pur, Calibration TERA MPV 200, 2, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

slice R1 did not converge therofor 9 steps
Entry  Sat Jun 13 00:01:43 2020, Felix Ulrich-Pur, Calibration TERA MPV 300, 3, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

 
Entry  Sat Jun 13 00:14:44 2020, Felix Ulrich-Pur, Calibration TERA MPV 400, 4, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

stopped because one slice could not be calibrated due to SW error
Entry  Sat Jun 13 00:29:22 2020, Felix Ulrich-Pur, Calibration TERA MPV 400, 5, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

S9 did not converge run stopped

 