  MedAustron 2020, Page 2 of 15  Not logged in ELOG logo
Entry  Sat Jun 13 00:01:43 2020, Felix Ulrich-Pur, Calibration TERA MPV 300, 3, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

 
Entry  Sat Jun 13 00:14:44 2020, Felix Ulrich-Pur, Calibration TERA MPV 400, 4, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

stopped because one slice could not be calibrated due to SW error
Entry  Sat Jun 13 00:29:22 2020, Felix Ulrich-Pur, Calibration TERA MPV 400, 5, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

S9 did not converge run stopped

 
Entry  Sat Jun 13 00:34:32 2020, Felix Ulrich-Pur, Calibration TERA MPV 400, 6, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

 
Entry  Sat Jun 13 00:54:47 2020, Felix Ulrich-Pur, Calibration TERA MPV 300, 7, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

repeated 300, because of SW error in previous run

 
Entry  Sat Jun 13 01:07:52 2020, Felix Ulrich-Pur, Calibration TERA MPV 200, 8, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

repeated 200, because of SW error in previous run

 
Entry  Sat Jun 13 01:29:35 2020, Felix Ulrich-Pur, Calibration TERA MPV 600, 9, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

few slices did not converge -> adapt range setting

 
Entry  Sat Jun 13 01:51:17 2020, Felix Ulrich-Pur, Calibration TERA MPV 600, 10, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , ,  
Setting 4

few slices did not converge -> adapted range setting

q9 and p3 did not converge-->choose mean voltage of group
Entry  Sat Jun 13 02:16:06 2020, Felix Ulrich-Pur, Calibration TERA Sr-90 Voltages, 11, TERA-Cal, 800, 10, 60, 20, 10, 6dB, , none, , 60000,  
1Setting 4

used same voltages as calibrated with Sr-90 (MPV 300)

 
Entry  Sat Jun 13 02:16:43 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 200MPV, 12, TERA-Cal, 100.4, BETA, , , EFE, , SID2, none, , 200000,  
Linearity Messung Gain 200MPV
Entry  Sat Jun 13 02:37:10 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 300MPV, 13, TERA-Cal, 100.4, BETA, , , EFE, , SID2, none, , 200000,  
Linearity Messung Gain 300MPV
Entry  Sat Jun 13 02:41:54 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 400MPV, 14, TERA-Cal, 100.4, BETA, , , EFE, , SID2, none, , 200000,  
Linearity Messung Gain 400MPV
Entry  Sat Jun 13 03:06:25 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 600MPV, 15, TERA-Cal, 100.4, BETA, , , EFE, , SID2, none, , 200000,  
Linearity Messung Gain 600MPV error in config file aborted
Entry  Sat Jun 13 03:06:44 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 600MPV, 16, TERA-Cal, 100.4, BETA, , , EFE, , SID2, none, , 200000,  
Linearity Messung Gain 600MPV
Entry  Sat Jun 13 03:06:58 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 300MPV, 17, TERA-Cal, 100.4, BETA, , , EFE, , SID2, none, , 200000,  
Linearity Messung Gain 300MPV previous voltages were not applied
Entry  Sat Jun 13 03:08:25 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 400MPV, 18, TERA-Cal, 100.4, BETA, , , EFE, , SID2, none, , 200000,  
Linearity Messung Gain 400MPV previous voltages were not applied
Entry  Sat Jun 13 03:08:39 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain Sr90, 19, TERA-Cal, 100.4, BETA, , , EFE, , SID2, none, , 200000,  
9Linearity Messung Gain Sr-90

Calibration from Lab not useful-> maybe different voltages if all slices are connected
Entry  Sat Jun 13 04:03:29 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 200, 20, TERA-Cal, 100.4, BETA, , , EFE, , , none, , 200000,  
Linearity Messung Gain 200 10e5 rate
Entry  Sat Jun 13 04:04:16 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 300, 21, TERA-Cal, 100.4, BETA, , , EFE, , , none, , 200000,  
Linearity Messung Gain 300 10e5 rate
Entry  Sat Jun 13 04:04:38 2020, Felix Ulrich-Pur, Linearity measurement TERA 100.4 gain 400, 22, TERA-Cal, 100.4, BETA, , , EFE, , , none, , 200000,  
Linearity Messung Gain 400 10e5 rate