Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2020, Page 15 of 15  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Subject Run Number DUT Beam Energy Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScandown PhantomType PhantomAngle Events Data Text Attachments
  268   Sat Nov 21 16:50:20 2020 Patrick Sieberer2020-11-2139DSSD-Tracker80010602010  none 670000 tracker moved 1cm up and 1cm left
tracker alignment (diamond read out,
but not in beam)
  
  269   Sat Nov 21 17:15:31 2020 Patrick Sieberer2020-11-2140Diamond + DSSD tracker80010602010  none 8621000 tracking

Edit Alex: Mir ist aufgefallen,
dass in ein paar Events zwischen den Events
 hitmap-68.pnghitmap-69.pnghitmap-70.pnghitmap-71.png 
  270   Sat Nov 21 20:09:13 2020 Patrick Sieberer2020-11-2141Diamond + DSSD tracker80010602010  none - inverse bias, local run   
  271   Sat Nov 21 20:16:35 2020 Patrick Sieberer2020-11-2142Diamond + DSSD tracker80010602010  none 550000 inverse bias, tracking, no hits in diamond
seen
  
  272   Sat Nov 21 20:32:27 2020 Patrick Sieberer2020-11-2143Diamond + DSSD tracker80010602010  none 495000Crapinverse bias, tracking, crap because wrong
polarity of APV channels
  
  273   Sat Nov 21 20:43:36 2020 Patrick Sieberer2020-11-2144Diamond + DSSD tracker80010602010  none  Unknownlocal run, (with switched APV channels)

Due to invers bias, p- and n-side
of diamond are also flipped!
  
  274   Sat Nov 21 21:30:16 2020 Patrick Sieberer2020-11-2145Diamond + DSSD tracker80010602010  none 3900000Unknowntracking, (with switched APV channels)

Due to invers bias, p- and n-side
of diamond are also flipped!
  
  275   Sun Dec 6 12:52:17 2020 Christian IrmlerMPW2 setup and configuration             First testbeam with MPW2, Setup as depicted
in attachment 1,

Default beam setting EFE/SID0 252
 Setup_for_first_MPW2_Beamtest.pdfShiftplan_MPW2shift_2020-12-06.pdf 
  291   Sun Dec 6 19:29:57 2020 Christian IrmlerMPW2210W13_04252.71  1   HV = 80V10 spills single pixel r0 c2

test run for new beam settings
  
  292   Sun Dec 6 19:30:38 2020 Christian IrmlerMPW2211W13_04252.71  1   HV = 80V10 spills pixle scan, starting with r0 c0

stopped after r0 c6 due network
error (oscilloscope connected)
  
  293   Sun Dec 6 19:51:49 2020 Christian IrmlerMPW2212W13_04252.71  1   HV = 80V10 spillsCrappixel scan, starting with r0 c7

stopped due to broken pipe

Caribou rebooted
  
Entry is currently edited by Felix Ulrich-Pur on 80.120.130.63    294   Sun Dec 6 20:04:27 2020 Christian IrmlerMPW2213W13_04252.71  1   HV = 80V10 spills pixel scan, starting with r0 c7

 
  
ELOG V3.1.5-fc6679b