Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2020, Page 14 of 15  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngleup Events Data Text Attachments
  211   Sun Oct 11 02:02:52 2020 Stefanie Kaser2020-10-1157Drehtisch100.41  1  Alu52.22.500.000 Start 01:28; Stop 01:50; PCT phase;    
  252   Sun Oct 11 17:59:18 2020 Albert Hirtl2020-10-1198Drehtisch100.41  1  Alu55.82500000 Start 18:00; Stop 18:21; PCT phase;    
  186   Sat Oct 10 15:17:51 2020 Manuel Christanell2020-10-1032Drehtisch100.41  1  Alu59.43.600.000 Start 15:16; PCT test phase;   
  260   Sun Oct 11 21:12:22 2020 Albert Hirtl2020-10-11106Drehtisch100.41  1  Alu61.22506000 Start 21:13; Stop 21:33; PCT phase;    
  212   Sun Oct 11 02:30:31 2020 Stefanie Kaser2020-10-1158Drehtisch100.41  1  Alu66.62.500.000 Start 01:52; Stop 02:12; PCT phase;    
  208   Sun Oct 11 00:54:40 2020 Stefanie Kaser2020-10-1154Drehtisch100.41  1  Alu7.22.500.000 Start 00:21; Stop 00:42; PCT phase;    
  261   Sun Oct 11 21:34:11 2020 Albert Hirtl2020-10-11107Drehtisch100.41  1  Alu72.02510000 Start 21:34; Stop 21:56; PCT phase;    
  205   Sun Oct 11 00:01:42 2020 Stefanie Kaser2020-10-1051Drehtisch100.41  1  Alu73.82.500.000 Start 22:49; Stop 23:32; PCT phase; beam
interruption (approx. 15 min)
  
  251   Sun Oct 11 17:33:38 2020 Albert Hirtl2020-10-1197Drehtisch100.41  1  Alu77.42534000 Start 17:34; Stop 17:58; PCT phase;    
  213   Sun Oct 11 02:43:58 2020 Stefanie Kaser2020-10-1159Drehtisch100.41  1  Alu81.02.500.000 Start 02:14; Stop 02:38; PCT phase;    
  250   Sun Oct 11 17:13:17 2020 Albert Hirtl2020-10-1196Drehtisch100.41  1  Alu86.42500000 Start 17:10; Stop 17:32; PCT phase;    
  183   Sat Oct 10 13:46:54 2020 Manuel Christanell2020-10-1029Drehtisch145.41  1  Alu903.200.000 Start 13:44; PCT test phase; Trigger events:
10.600.000;
  
  184   Sat Oct 10 14:17:59 2020 Manuel Christanell2020-10-1030Drehtisch100.41  1  Alu903.300.000 Start 14:14; PCT test phase;   
  262   Sun Oct 11 21:56:52 2020 Albert Hirtl2020-10-11108Drehtisch100.41  1  Alu91.81326000 Start 21:57; Stop 22:10; PCT phase;    
  214   Sun Oct 11 03:07:56 2020 Stefanie Kaser2020-10-1160Drehtisch100.41  1  Alu97.22.500.000 Start 02:39; Stop 03:04; PCT phase;    
  282   Sun Dec 6 15:45:45 2020 Christian IrmlerMPW2201W13_04252.7   1 SID0 HV = 100V10 spills r0 c2   
  284   Sun Dec 6 15:55:13 2020 Christian IrmlerMPW2203W13_04252.7   1 SID0 HV = 1V10 spills r0 c2

lowest Voltage, which could be
set with SMU outputs on.
  
  285   Sun Dec 6 15:57:28 2020 Christian IrmlerMPW2204W13_04252.7   1 SID0 HV = 20V10 spills r0 c2   
  279   Sun Dec 6 15:41:31 2020 Christian IrmlerMPW2199W13_04252.7   1 SID0 HV = 40V10 spills HV = 40V

r0 c2
  
  278   Sun Dec 6 15:38:59 2020 Christian IrmlerMPW2198W13_04252.7   1 SID0 HV = 60V10 spills HV = 60V

r0 c2
  
ELOG V3.1.5-fc6679b