Fri Oct 25 18:09:21 2019, Alexander Burker, 2019-10-20 Low Flux, , 800, EFE 1us, Degrader10, changed gain orb, gain 6, betatron10, no chopper, 1, 22743, none,
|
06:25
WRONG GAIN ON THE ORB
tracker was not properly configured at the beginning, but now is working |
Fri Oct 25 18:21:58 2019, Alexander Burker, 2019-10-20 Low Flux, , 800, EFE 1us, Degrader20, changed gain orb, gain 6, no betatron, chopper 60, 2, 22841, none,
|
06:36
WRONG GAIN ON THE ORB
lots of empty spills |
Fri Oct 25 18:23:05 2019, Alexander Burker, 2019-10-20 Low Flux, , 800, EFE 1us, Degrader20, Betatron50, No Chopper, 3, , none,
|
06:50 - no beam
06:55 - accelerator fail, still no beam
07:07 - no beam with gain 6 |
Fri Oct 25 18:24:42 2019, Alexander Burker, 2019-10-20 Low Flux, , 800, EFE 1us, Degrader20, Betatron50, No Chopper, Gain 26, 4, 35365, none,
|
07:09 - chainged to 26 and saw beam
lots of empty spulls
|
Fri Oct 25 18:25:34 2019, Alexander Burker, 2019-10-20 Low Flux, , 800, EFE 1us, Degrader20, changed gain orb, gain 26, Betatron 100, Chopper 60, 5, 39836, none,
|
07:23
lots of empty spills, looks like kHz-ish
|
Fri Oct 25 18:26:09 2019, Alexander Burker, 2019-10-20 Low Flux, , 800, EFE 1us, Degrader10, changed gain orb, gain 26, betatron10, Chopper 100, 6, 54546, none,
|
07:43
few empty spills
|
Fri Oct 25 18:27:38 2019, Alexander Burker, 2019-10-20 Low Flux, , 800, Setting 4 with 6db gain on the orb, 7, 47862, none,
|
08:02
again 5s pause between spills, looks stable |
Fri Oct 25 18:28:15 2019, Alexander Burker, 2019-10-20 Low Flux, , 252.7, Betatron + EFE, 8, 19365, none,
|
08:45 looks fine
|
Fri Oct 25 18:29:04 2019, Alexander Burker, 2019-10-20 Low Flux, , 145.4, Betatron + EFE, 9, 27472, none,
|
08:55
looks fine
|
Fri Oct 25 18:31:58 2019, Alexander Burker, 2019-10-20 Low Flux, , 252.7, EFE, QuadScan SID0, 10, 24368, none,
|
09:15
looks fine
|
Fri Oct 25 18:32:32 2019, Alexander Burker, 2019-10-20 Low Flux, , 145.4, EFE, QuadScan SID0, 11, 20626, none,
|
09:30
looks fine, one scinti0 looks noisy
|
Fri Oct 25 18:32:55 2019, Alexander Burker, 2019-10-20 Low Flux, , 252.7, EFE, QuadScan SID2, 12, 75742, none,
|
09:45
fine, one scinti0 looks noisy
|
Fri Oct 25 18:33:22 2019, Alexander Burker, 2019-10-20 Low Flux, , 145.4, EFE, QuadScan SID2, 13, 77148, none,
|
09:55
one scinti0 looks noisy
|
Fri Oct 25 18:34:26 2019, Alexander Burker, 2019-10-20 Low Flux, , 145.4, EFE, QuadScan SID2, 14, , none,
|
10:00
scinti0 threshold 25 instead of 20, noise better |
Fri Oct 25 18:34:34 2019, Alexander Burker, 2019-10-20 Low Flux, , 145.4, EFE, QuadScan SID2, 15, , none,
|
10:03
scinti0 threshold 30 instead of 20, signal same for both scintis, noise didnt change rate much, other scinti was stable at 20mV threshold
|
Fri Oct 25 18:34:51 2019, Alexander Burker, 2019-10-20 Low Flux, , 252.7, Degrader 10, 16, 567296, none,
|
10:25
change position of lgad form +125 step to 0(isocentre) in 25stepsized steps
|
Fri Oct 25 18:35:17 2019, Alexander Burker, 2019-10-20 Low Flux, , 252.7, Degrader 10, 17, 474112, none,
|
10:45 Room request changed osci from remote to hd camera
11:00 same setting as with run 16, but in centre
|
Fri Oct 25 18:35:47 2019, Alexander Burker, 2019-10-20 Low Flux, , 252.7, Degrader 10, 18, 507392, none,
|
11:22 same as 17
|
Fri Oct 25 18:36:01 2019, Alexander Burker, 2019-10-20 Low Flux, , 252.7, Degrader 10, 19, 363008, none,
|
11:40 same as 17, flo changed bias in lgads
|
Fri Oct 25 18:36:21 2019, Alexander Burker, 2019-10-20 Low Flux, , 145.4, Degrader 10, 20, 304640, none,
|
12:06 medical
|
|