ID Date Authordown Subject DUT Beam Energy Beam Setting Run Number Events PhantomType PhantomAngle
  60   Fri Oct 25 18:34:26 2019 Alexander Burker2019-10-20 Low Flux 145.4EFE, QuadScan SID214 none 

10:00
scinti0 threshold 25 instead of 20, noise better

  61   Fri Oct 25 18:34:34 2019 Alexander Burker2019-10-20 Low Flux 145.4EFE, QuadScan SID215 none 

10:03
scinti0 threshold 30 instead of 20, signal same for both scintis, noise didnt change rate much, other scinti was stable at 20mV threshold
 

  62   Fri Oct 25 18:34:51 2019 Alexander Burker2019-10-20 Low Flux 252.7Degrader 1016567296none 

10:25
change position of lgad form +125 step to 0(isocentre) in 25stepsized steps

  63   Fri Oct 25 18:35:17 2019 Alexander Burker2019-10-20 Low Flux 252.7Degrader 1017474112none 

10:45 Room request changed osci from remote to hd camera

11:00 same setting as with run 16, but in centre

  64   Fri Oct 25 18:35:47 2019 Alexander Burker2019-10-20 Low Flux 252.7Degrader 1018507392none 

11:22  same as 17

  65   Fri Oct 25 18:36:01 2019 Alexander Burker2019-10-20 Low Flux 252.7Degrader 1019363008none 

11:40 same as 17, flo changed bias in lgads

  66   Fri Oct 25 18:36:21 2019 Alexander Burker2019-10-20 Low Flux 145.4Degrader 1020304640none 

12:06 medical

  67   Fri Oct 25 18:36:52 2019 Alexander Burker2019-10-20 Low Flux 145.4Degrader 2021162816none 

12:20 medical

  68   Fri Oct 25 18:40:03 2019 Alexander Burker2019-10-20 Low Flux 145.4Degrader 5022235520none 

12:30 medical

  69   Fri Oct 25 18:40:33 2019 Alexander Burker2019-10-20 Low Flux 100.4Degrader 1023343040none 

12:43 

  70   Fri Oct 25 18:41:09 2019 Alexander Burker2019-10-20 Low Flux 100.4Degrader 2024185344none 

13:00

  71   Fri Oct 25 18:41:36 2019 Alexander Burker2019-10-20 Low Flux 252.7Degrader 2025271872none 

13:10

  72   Fri Oct 25 18:42:39 2019 Alexander Burker2019-10-20 Low Flux 252.7Degrader 5026163328none 

13:24

  73   Fri Oct 25 18:43:09 2019 Alexander Burker2019-10-20 Low Flux 800Setting Nr 12731771none 

13:40 lots of empty spills

  74   Fri Oct 25 18:44:07 2019 Alexander Burker2019-10-20 Low Flux 800Setting Nr 42811442none 

13:52

  75   Fri Oct 25 18:45:20 2019 Alexander Burker2019-10-20 Low Flux   2922002none 

  76   Fri Oct 25 18:50:08 2019 Alexander Burker2019-10-20 Low FluxSketch      

Spot Sizes Table: SpotsForBeamSettings.csv

Empirics, such as P2, P25, Median, P75 and P98 were obtained directly from the data. These may not be accurate if the beam is larger than the sensor.

To better describe these cases, fit values were obtained with a curve fit to a normal distribution. This can also be inaccurate, as many beam settings aren't normal and the automatic fit might have failed. A goodness-of-fit will be added to each row in the distant future

  77   Fri Oct 25 18:56:11 2019 Alexander Burker2019-07-13f proton CTSketch    none 

Spot sizes table: SpotsForBeamSettings.csv

Empirics, such as P2, P25, Median, P75 and P98 were obtained directly from the data. These may not be accurate if the beam is larger than the sensor.

To better describe these cases, fit values were obtained with a curve fit to a normal distribution. This can also be inaccurate, as many beam settings aren't normal and the automatic fit might have failed. A goodness-of-fit will be added to each row in the distant future

  78   Fri Oct 25 23:04:42 2019 Alexander Burker2019-10-25 Low Flux 800EFE 10, Betatron 10 %, Chopper 60 %, Degrader 20, Orb Gain 6 dB133784none 

  79   Sat Oct 26 00:36:35 2019 Alexander Burker2019-10-25 Low Flux   21132none 