ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
18
|
Tue Jan 7 02:18:26 2014 |
Markus Friedl | Infineon | run | run013 | 215k | 07.01.2014 02:14:50 | 07.01.2014 08:31:25 | Crap |
HV=150V I=7.90uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum
close to end: switched to 6GeV
bias voltage accidentally left at 150V instead of initially planned 290V |
17
|
Tue Jan 7 02:17:14 2014 |
Thomas Bergauer | | beam momentum 6GeV/c | run013 | | | | Unknown |
|
15
|
Tue Jan 7 00:36:03 2014 |
Markus Friedl | Infineon | run | run012 | 190k | 07.01.2014 00:33:58 | 07.01.2014 02:12:32 | Good |
HV=150V I=8.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum
close to end: switched to 6GeV |
14
|
Mon Jan 6 23:50:59 2014 |
Markus Friedl | Infineon | run | run011 | 200k | 06.01.2014 23:49:09 | 07.01.2014 00:30:38 | Good |
HV=280V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
13
|
Mon Jan 6 23:06:51 2014 |
Markus Friedl | Infineon | run | run010 | 200k | 06.01.2014 23:03:23 | 06.01.2014 23:47:02 | Good |
HV=270V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
12
|
Mon Jan 6 22:23:39 2014 |
Markus Friedl | Infineon | run | run009 | 200k | 06.01.2014 22:22:10 | 06.01.2014 23:03:23 | Good |
HV=260V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
11
|
Mon Jan 6 21:40:29 2014 |
Markus Friedl | Infineon | run | run008 | 200k | 06.01.2014 21:38:46 | 06.01.2014 22:20:13 | Good |
HV=210V I=9.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
10
|
Mon Jan 6 20:57:38 2014 |
Markus Friedl | Infineon | run | run007 | 200k | 06.01.2014 20:56:08 | 06.01.2014 21:36:54 | Good |
HV=220V I=9.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
9
|
Mon Jan 6 20:14:21 2014 |
Markus Friedl | Infineon | run | run006 | 200k | 06.01.2014 20:12:20 | 06.01.2014 20:54:34 | Good |
HV=240V I=9.4uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
8
|
Mon Jan 6 19:31:44 2014 |
Markus Friedl | AIDA | run | run005 | 200k | 06.01.2014 19:29:52 | 06.01.2014 20:09:59 | Good |
HV=230V I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
7
|
Mon Jan 6 19:10:36 2014 |
Thomas Bergauer | common | Beam Momentum 3GeV/c | run001 to run012 | | | | Unknown |
We have set the beam momentum to 3 GeV |
Attachment 1: IMG_1517.jpg
|
 |
Attachment 2: IMG_1516.jpg
|
 |
6
|
Mon Jan 6 18:49:00 2014 |
Markus Friedl | Infineon | run | run004 | 200k | 06.01.2014 18:47:38 | 06.01.2014 19:27:33 | Good |
HV=250V I=9.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
5
|
Mon Jan 6 18:06:16 2014 |
Markus Friedl | Infineon | run | run003 | 200k | 06.01.2014 18:04:14 | 06.01.2014 18:44:15 | Good |
HV=200V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
4
|
Mon Jan 6 17:17:47 2014 |
Markus Friedl | Infineon | run | run002 | 200k | 06.01.2014 17:14:39 | 06.01.2014 18:00:34 | Good |
HV=100V I=8.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
3
|
Mon Jan 6 16:33:13 2014 |
Markus Friedl | Infineon | run | run001 | 200k | 06.01.2014 16:28:58 | 06.01.2014 17:10:56 | Good |
HV=300V I=11.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
2
|
Sun Jan 5 15:08:09 2014 |
Markus Friedl | AIDA | cal | cal002 | 83800 | 05.01.2014 15:01:32 | 05.01.2014 15:30:36 | Good |
HV=100V I=6uA |
1
|
Sat Jan 4 16:30:46 2014 |
Markus Friedl | Infineon | cal | cal001 | 83800 | 04.01.2014 16:16:51 | 04.01.2014 16:25:46 | Good |
HV=300V I=9.3uA (total) |