Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 4 of 5  Not logged in ELOG logo
ID Date Author Projectdown Subject Run Number Events StartTime EndTime Data Text Attachments
  98   Wed Jan 29 22:40:09 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_pos2_002200k29.01.2014 22:4029.01.2014 23:15GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
Position changed to --8.91097 -22.80061
  
  20   Tue Jan 7 09:12:24 2014 Thomas BergauerBelle SVDrunrun01520k07.01.2014 09:10:5207.01.2014 09:15:39Good HV=290V  I=9.55uA
position centered horizontally
(+5mm)
DESY table z=-346 x=-255
 
energy
  
  28   Tue Jan 7 14:51:45 2014 Thomas BergauerBelle SVDTLU control    Unknown1. ssh bastion
2. ssh belle-control
3. ssh 
  
  59   Fri Jan 10 11:02:31 2014 Markus FriedlBelle SVDPower supply  10.01.2014 11:00:00 Unknown   KenWood100114.png 
  2   Sun Jan 5 15:08:09 2014 Markus FriedlAIDAcalcal0028380005.01.2014 15:01:3205.01.2014 15:30:36GoodHV=100V  I=6uA   
  8   Mon Jan 6 19:31:44 2014 Markus FriedlAIDArunrun005200k06.01.2014 19:29:5206.01.2014 20:09:59GoodHV=230V  I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  41   Wed Jan 8 12:40:30 2014 Thomas BergauerAIDAintcal AIDA Stackcal03483.8k08.01.2014 12:32:2208.01.2014 13:01:30Unknown HV=100V  I=4.5uA
position adapted to center beam
 
  
  42   Wed Jan 8 14:10:07 2014 Thomas BergauerAIDArunrun03521168108.01.2014 14:01:2508.01.2014 17:03:55Unknown HV=100V  I=4.2uA
position adapted to center beam
 
accidentally
hit reset button on PC which ended this run
  
  43   Wed Jan 8 17:20:40 2014 Markus FriedlAIDArunrun036320k08.01.2014 17:18:5108.01.2014 22:14:58Unknown HV=100V  I=4.3uA
centered position
5GeV beam
  
  44   Wed Jan 8 22:19:11 2014 Markus FriedlAIDArunrun0371.2M08.01.2014 22:18:3009.01.2014 10:08:14GoodHV=100V  I=4.4uA
centered position
5GeV beam, single sample
  
  45   Thu Jan 9 10:10:31 2014 Markus FriedlAIDAcalcal0388380009.01.2014 10:09:2709.01.2014 10:38:23GoodHV=100V  I=4.2uA
centered position
5GeV beam, single sample
  
  46   Thu Jan 9 11:02:14 2014 Markus FriedlAIDAinfo    UnknownCreated bad strip masks for the AIDA config
files
  
  47   Thu Jan 9 11:04:34 2014 Markus FriedlAIDArunrun039100k09.01.2014 11:02:3609.01.2014 12:28:41GoodHV=10V  I=2.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  48   Thu Jan 9 12:31:29 2014 Markus FriedlAIDArunrun040100k09.01.2014 12:30:3209.01.2014 13:55:47GoodHV=20V  I=2.9uA
centered position, HV scan
5GeV beam, 6 samples
  
  49   Thu Jan 9 14:07:31 2014 Markus FriedlAIDArunrun041100k09.01.2014 14:06:3209.01.2014 15:33:13GoodHV=30V  I=3.3uA
centered position, HV scan
5GeV beam, 6 samples
  
  51   Thu Jan 9 16:36:30 2014 Markus FriedlAIDArunrun042100k09.01.2014 16:35:4309.01.2014 18:02:17GoodHV=40V  I=3.4uA
centered position, HV scan
5GeV beam, 6 samples
  
  52   Thu Jan 9 18:09:40 2014 Markus FriedlAIDArunrun044100k09.01.2014 18:08:1909.01.2014 19:35:21GoodHV=50V  I=3.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  53   Thu Jan 9 19:37:33 2014 Markus FriedlAIDArunrun045100k09.01.2014 19:36:2109.01.2014 21:01:31 GoodHV=60V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  54   Thu Jan 9 21:41:20 2014 Markus FriedlAIDArunrun046100k09.01.2014 21:40:2909.01.2014 23:07:16GoodHV=70V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  55   Thu Jan 9 23:27:27 2014 Markus FriedlAIDArunrun047100k09.01.2014 23:26:3510.01.2014 00:52:56GoodHV=80V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
ELOG V3.1.5-fc6679b