Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 4 of 5
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Project --
common
Belle SVD
Infineon
AIDA
-- Data --
Unknown
Good
Crap
97 Entries
Goto page
Previous
1
,
2
,
3
, 4,
5
Next
All
ID
Date
Author
Project
Subject
Run Number
Events
StartTime
EndTime
Data
Text
31
Tue Jan 7 16:36:49 2014
Markus Friedl
Infineon
run
run024
200k
07.01.2014 16:35:44
07.01.2014 17:03:10
Good
HV=210V I=8.1uA
position adapted to center beam better
(+10mm horizontal)
30
Tue Jan 7 15:54:22 2014
Markus Friedl
Infineon
run
run023
200k
07.01.2014 15:53:06
07.01.2014 16:25:26
Good
HV=200V I=8.0uA
position adapted to center beam better
(+10mm horizontal)
29
Tue Jan 7 15:16:11 2014
Markus Friedl
Infineon
run
run022
200k
07.01.2014 15:15:09
07.01.2014 15:42:17
Good
HV=150V I=7.3uA
position adapted to center beam better
(+10mm horizontal)
27
Tue Jan 7 14:47:38 2014
Markus Friedl
Infineon
run
run021
200k
07.01.2014 14:46:08
07.01.2014 15:13:23
Good
HV=100V I=7.2uA
position adapted to center beam better
(+10mm horizontal)
26
Tue Jan 7 13:20:48 2014
Markus Friedl
Infineon
run
run020
300k
07.01.2014 13:18:52
07.01.2014 14:35:49
Good
HV=300V I=8.5uA
position adapted to center beam better
(+10mm horizontal)
25
Tue Jan 7 11:52:27 2014
Markus Friedl
Infineon
run
run019
650k
07.01.2014 11:47:24
07.01.2014 13:15:21
Good
HV=300V I=9.2uA
position adapted to center beam better
(+10mm horizontal)
22
Tue Jan 7 09:33:16 2014
Thomas Bergauer
run
run017
100k
07.01.2014 09:31:45
07.01.2014 09:52:58
Good
HV=300V I=9.08uA
position
adapted to center beam better (+10mm horizonal)
DESY
table z=-346 x=-255
21
Tue Jan 7 09:22:09 2014
Thomas Bergauer
run
run016
50k
07.01.2014 09:19:10
07.01.2014 09:30:03
Good
HV=290V I=9.00uA
position
move back to original position (0mm/0mm)
(not hitting the right APVs anymore)
DESY
20
Tue Jan 7 09:12:24 2014
Thomas Bergauer
Belle SVD
run
run015
20k
07.01.2014 09:10:52
07.01.2014 09:15:39
Good
HV=290V I=9.55uA
position centered horizontally
(+5mm)
DESY table z=-346 x=-255
energy
19
Tue Jan 7 08:36:29 2014
Thomas Bergauer
Infineon
run
run014
20k
07.01.2014 08:34:06
07.01.2014 09:05:47
Good
HV=290V I=9.55uA
position
centered horizontally (+5mm)
DESY
table z=-346 x=-255
18
Tue Jan 7 02:18:26 2014
Markus Friedl
Infineon
run
run013
215k
07.01.2014 02:14:50
07.01.2014 08:31:25
Crap
HV=150V I=7.90uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
15
Tue Jan 7 00:36:03 2014
Markus Friedl
Infineon
run
run012
190k
07.01.2014 00:33:58
07.01.2014 02:12:32
Good
HV=150V I=8.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
14
Mon Jan 6 23:50:59 2014
Markus Friedl
Infineon
run
run011
200k
06.01.2014 23:49:09
07.01.2014 00:30:38
Good
HV=280V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
13
Mon Jan 6 23:06:51 2014
Markus Friedl
Infineon
run
run010
200k
06.01.2014 23:03:23
06.01.2014 23:47:02
Good
HV=270V I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
12
Mon Jan 6 22:23:39 2014
Markus Friedl
Infineon
run
run009
200k
06.01.2014 22:22:10
06.01.2014 23:03:23
Good
HV=260V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
11
Mon Jan 6 21:40:29 2014
Markus Friedl
Infineon
run
run008
200k
06.01.2014 21:38:46
06.01.2014 22:20:13
Good
HV=210V I=9.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
10
Mon Jan 6 20:57:38 2014
Markus Friedl
Infineon
run
run007
200k
06.01.2014 20:56:08
06.01.2014 21:36:54
Good
HV=220V I=9.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
9
Mon Jan 6 20:14:21 2014
Markus Friedl
Infineon
run
run006
200k
06.01.2014 20:12:20
06.01.2014 20:54:34
Good
HV=240V I=9.4uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
8
Mon Jan 6 19:31:44 2014
Markus Friedl
AIDA
run
run005
200k
06.01.2014 19:29:52
06.01.2014 20:09:59
Good
HV=230V I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
6
Mon Jan 6 18:49:00 2014
Markus Friedl
Infineon
run
run004
200k
06.01.2014 18:47:38
06.01.2014 19:27:33
Good
HV=250V I=9.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255