Entry  Tue Jan 7 09:33:51 2014, Thomas Bergauer, common, beam momentum back to 3Gev/c, run014 and later ones, , , , Unknown 
 
Entry  Tue Jan 7 02:17:14 2014, Thomas Bergauer, , beam momentum 6GeV/c, run013, , , , Unknown 
 
Entry  Tue Jan 7 14:51:45 2014, Thomas Bergauer, Belle SVD, TLU control, , , , , Unknown 

1. ssh bastion

2. ssh belle-control

3. ssh telescope-admin@tb-aconite
(password telescope++)

dann:

How to generate trigger from TLU through FTSW to detector systems
2014.1.6 Mikihiko Nakao

* step 1 - open monitor window to show the FTSW status

 [you@bastion03 ~]$ ssh telescope-admin@belle-rpc1
  (still only limited people has access to b2daq account:
   ask DAQ people or Katsuro Nakamura of SVD group)

 [b2daq@belle-rpc1 ~]$ ssh telescope-admin@ttd10
 [b2daq@ttd10 ~]$ statft -55 -i -c
   (55 is the FTSW board-id, -i -c are to show the status repeatedly)

* step 2 - initialize FTSW to accept TLU trigger

 [b2daq@ttd10 ~]$ trigft -55 tlu

* step 3 - start trigger at TLU

 [you@bastion03 ~]$ ssh belle-rpc2
 [you@belle-rpc2 ~]$ ssh telescope-admin@tb-aconite
  (ask Alan Campbell or somebody for the password)

 telescope-admin@tb-aconite:~$ cd eudaq-nakao/bin
 ...$ ./TLUControl.exe -a 4 -d 1 -i RJ45 -w 10 -n

 here, -a option gives the possible trigger coincidence
  (-a 1  --- dummy trigger generator from FTSW)
   -a 2  --- trigger counter 1 only
   -a 4  --- trigger counter 2 only
   -a 8  --- trigger counter 3 only
   -a 6  --- trigger counter 1 and 2
   -a 10 --- trigger counter 1 and 3
   -a 12 --- trigger counter 2 and 2
   -a 14 --- trigger counter 1 and 2 and 3
 other options are kept to be the same
   -d 1 -i RJ45 --- connection to FTSW
   -w 10        --- update frequency (10msec)
   -n           --- suppress messages

 This gives you output like:

   Status:    00,--,--,--,--,-- (0,0)
   Scalers:   0, 7, 0, 0    <== from FTSW-dummy and trigger counters 1, 2, 3
   Particles: 1
   Triggers:  0             <== actual trigger to be distributed to FTSW
   Entries:   0
   TS errors: 0, 0 (redundancy, re-read)
   Timestamp: 0x4f25a008 (1327865864) = 3.45791
   Time: 3.463 s, Freq: 0 Hz, Average: 0 Hz

- 

Entry  Wed Jan 29 12:02:52 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_001, 100k, 28.01.2014 16:30, 28.01.2014 16:50, Good 

HV at 0V; I at app. 5nA 3GeV, Single mode

 

Entry  Wed Jan 29 12:04:53 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_002, 140k, 28.01.2014 16:50, 28.01.2014 17:20, Good 

HV at 100V; I at app. 8.5µA 3GeV, Single mode

 

Entry  Wed Jan 29 12:07:48 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_003, 200k, 28.01.2014 17:40, 28.01.2014 18:20, Good 

HV at 150V; I at app. 9µA 3GeV, Single mode

 

Entry  Wed Jan 29 12:08:52 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_004, 200k, 28.01.2014 19:30, 28.01.2014 20:00, Good 

HV at 200V; I at app. 9.5µA 3GeV, Single mode

 

Entry  Wed Jan 29 12:10:06 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_005, 200k, 28.01.2014 20:00, 28.01.2014 23:00, Good 

HV at 210V; I at app. 8.5µA 3GeV, Single mode

 

Entry  Wed Jan 29 12:11:00 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_006, 200k, 28.01.2014 20:30, 28.01.2014 21:00, Good 

HV at 220V; I at app. 8.5µA 3GeV, Single mode

 

Entry  Wed Jan 29 21:55:09 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_007, 200k, 29.01.2014 11:50, 29.01.2014 12:15, Good 

HV at 230V; I at app. 8µA 3GeV, Single mode

 

Entry  Wed Jan 29 21:56:15 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_008, 200k, 29.01.2014 12:15, 29.01.2014 12:45, Good 

HV at 240V; I at app. 7.5µA 3GeV, Single mode

 

Entry  Wed Jan 29 21:56:58 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_009, 110k, 29.01.2014 12:50, 29.01.2014 13:15, Good 

HV at 250V; I at app. 7.5µA 3GeV, Single mode

 

Entry  Wed Jan 29 21:57:55 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_010, 100k, 29.01.2014 13:20, 29.01.2014 13:35, Good 

HV at 260V; I at app. 7.6µA 3GeV, Single mode

 

Entry  Wed Jan 29 21:59:51 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_011, 200k, 29.01.2014 13:45, 29.01.2014 14:20, Good 

HV at 270V; I at app. 7.6µA 3GeV, Single mode

 

Entry  Wed Jan 29 22:01:08 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_012, 200k, 29.01.2014 14:25, 29.01.2014 15:26, Good 

HV at 280V; I at app. 8µA 3GeV, Single mode

 

Entry  Wed Jan 29 22:02:04 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_013, 200k, 29.01.2014 15:26, 29.01.2014 17:00, Good 

HV at 290V; I at app. 8µA 3GeV, Single mode

 

Entry  Wed Jan 29 22:03:15 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_014, 200k, 29.01.2014 18:15, 29.01.2014 18:45, Good 

HV at 260V; I at app. 7.5µA 3GeV, Single mode

 

Entry  Wed Jan 29 22:06:12 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_015, 200k, 29.01.2014 19:15, 29.01.2014 19:45, Good 

HV at 300V; I at app. 7.5µA 3GeV, Single mode

 

Entry  Wed Jan 29 22:08:48 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, , , 29.01.2014 22:00, 29.01.2014 22:00, Good 

All Infineon Stack 2 runs have been taken at table position: 1.089030, -12.800610

 

Entry  Wed Jan 29 22:36:35 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_pos1_001, 200k, 29.01.2014 22:15, 29.01.2014 22:35, Good 

HV at 300V; I at app. 7.5µA 3GeV, Single mode

Position changed to -3.910970 -17.800610

 