Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 4 of 5  Not logged in ELOG logo
Entry  Tue Jan 7 20:26:50 2014, Markus Friedl, Infineon, run, run031, 200k, 07.01.2014 20:25:32, 07.01.2014 20:58:47, Good 
HV=280V  I=8.4uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 19:44:45 2014, Markus Friedl, Infineon, run, run030, 200k, 07.01.2014 19:43:35, 07.01.2014 20:11:03, Good 
HV=270V  I=8.6uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 19:12:07 2014, Markus Friedl, Infineon, run, run029, 200k, 07.01.2014 19:11:05, 07.01.2014 19:38:00, Good 
HV=260V  I=8.7uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 18:41:55 2014, Markus Friedl, Infineon, run, run028, 200k, 07.01.2014 18:40:40, 07.01.2014 19:07:32, Good 
HV=250V  I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 18:11:52 2014, Markus Friedl, Infineon, run, run027, 200k, 07.01.2014 18:10:45, 07.01.2014 18:37:42, Good 
HV=240V  I=8.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 17:39:20 2014, Markus Friedl, Infineon, run, run026, 200k, 07.01.2014 17:38:01, 07.01.2014 18:05:11, Good 
HV=230V  I=8.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 17:09:56 2014, Markus Friedl, Infineon, run, run025, 200k, 07.01.2014 17:08:54, 07.01.2014 17:36:12, Good 
HV=220V  I=8.1uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 16:36:49 2014, Markus Friedl, Infineon, run, run024, 200k, 07.01.2014 16:35:44, 07.01.2014 17:03:10, Good 
HV=210V  I=8.1uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 15:54:22 2014, Markus Friedl, Infineon, run, run023, 200k, 07.01.2014 15:53:06, 07.01.2014 16:25:26, Good 
HV=200V  I=8.0uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 15:16:11 2014, Markus Friedl, Infineon, run, run022, 200k, 07.01.2014 15:15:09, 07.01.2014 15:42:17, Good 
HV=150V  I=7.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 14:51:45 2014, Thomas Bergauer, Belle SVD, TLU control, , , , , Unknown 
1. ssh bastion
2. ssh belle-control
3. ssh telescope-admin@tb-aconite
Entry  Tue Jan 7 14:47:38 2014, Markus Friedl, Infineon, run, run021, 200k, 07.01.2014 14:46:08, 07.01.2014 15:13:23, Good 
HV=100V  I=7.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 13:20:48 2014, Markus Friedl, Infineon, run, run020, 300k, 07.01.2014 13:18:52, 07.01.2014 14:35:49, Good 
HV=300V  I=8.5uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 11:52:27 2014, Markus Friedl, Infineon, run, run019, 650k, 07.01.2014 11:47:24, 07.01.2014 13:15:21, Good 
HV=300V  I=9.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
Entry  Tue Jan 7 11:50:34 2014, Markus Friedl, Infineon, scan, run018x, 10k, 07.01.2014 11:xx:xx, 07.01.2014 11:xx:xx, Good 
Delay scan with single sample
Several runs
Entry  Tue Jan 7 09:33:51 2014, Thomas Bergauer, common, beam momentum back to 3Gev/c, run014 and later ones, , , , Unknown 
 
Entry  Tue Jan 7 09:33:16 2014, Thomas Bergauer, , run, run017, 100k, 07.01.2014 09:31:45, 07.01.2014 09:52:58, Good 
HV=300V  I=9.08uA
position adapted to center beam better (+10mm horizonal)
DESY table z=-346 x=-255 
3Gev/c
Entry  Tue Jan 7 09:22:09 2014, Thomas Bergauer, , run, run016, 50k, 07.01.2014 09:19:10, 07.01.2014 09:30:03, Good 
HV=290V  I=9.00uA
position move back to original position (0mm/0mm) (not hitting the right APVs anymore)
DESY
table z=-346 x=-255 
Entry  Tue Jan 7 09:12:24 2014, Thomas Bergauer, Belle SVD, run, run015, 20k, 07.01.2014 09:10:52, 07.01.2014 09:15:39, Good 
 HV=290V  I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
 
energy switched back to 3Gev/c
Entry  Tue Jan 7 08:36:29 2014, Thomas Bergauer, Infineon, run, run014, 20k, 07.01.2014 08:34:06, 07.01.2014 09:05:47, Good 
HV=290V  I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 
6Gev/c,
bad strip region hardly hit
ELOG V3.1.5-fc6679b