| ID | 
Date | 
Author | 
Project | 
Subject | 
Run Number | 
Events  | 
StartTime | 
EndTime | 
Data | 
Text | 
  | 
| 
  97  
 | 
Wed Jan 29 22:36:35 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_pos1_001 | 200k | 29.01.2014 22:15 | 29.01.2014 22:35 | Good | HV at 300V; I at app. 7.5µA 3GeV, 
Single mode
 
Position changed to -3.910970 -17.800610 | 
   | 
| 
  98  
 | 
Wed Jan 29 22:40:09 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_pos2_002 | 200k | 29.01.2014 22:40 | 29.01.2014 23:15 | Good | HV at 300V; I at app. 7.5µA 3GeV, 
Single mode
 
Position changed to --8.91097 -22.80061 | 
   | 
| 
  15  
 | 
Tue Jan  7 00:36:03 2014 | 
Markus Friedl | Infineon | run | run012 | 190k | 07.01.2014  00:33:58 | 07.01.2014  02:12:32  | Good | HV=150V  I=8.0uA
 
position centered horizontally (+5mm)
 
DESY table z=-346 x=-255 | 
   | 
| 
  82  
 | 
Wed Jan 29 12:04:53 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_002 | 140k | 28.01.2014 16:50 | 28.01.2014 17:20 | Good | HV at 100V; I at app. 8.5µA 3GeV, 
Single mode
 
  | 
   | 
| 
  79  
 | 
Sun Jan 26 19:14:07 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 | HW_Run_Infineon_Stack2_003 | 140 k | 26.01.2014 18:10 | 26.01.2014 19:15 | Good | HV at 300V; I at app. 10µA 5GeV, 
Single mode
 
  | 
   | 
| 
  89  
 | 
Wed Jan 29 21:56:58 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_009 | 110k | 29.01.2014 12:50 | 29.01.2014 13:15 | Good | HV at 250V; I at app. 7.5µA 3GeV, 
Single mode
 
  | 
   | 
| 
  24  
 | 
Tue Jan  7 11:50:34 2014 | 
Markus Friedl | Infineon | scan | run018x | 10k | 07.01.2014 11:xx:xx | 07.01.2014 11:xx:xx | Good | Delay scan with single sample
 
Several runs | 
   | 
| 
  22  
 | 
Tue Jan  7 09:33:16 2014 | 
Thomas Bergauer |   | run | run017 | 100k | 07.01.2014  09:31:45 | 07.01.2014  09:52:58 | Good | HV=300V  I=9.08uA
 
position 
adapted to center beam better (+10mm horizonal)
 
DESY 
table z=-346 x=-255  | 
   | 
| 
  47  
 | 
Thu Jan  9 11:04:34 2014 | 
Markus Friedl | AIDA | run | run039 | 100k | 09.01.2014  11:02:36 | 09.01.2014  12:28:41 | Good | HV=10V  I=2.1uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  48  
 | 
Thu Jan  9 12:31:29 2014 | 
Markus Friedl | AIDA | run | run040 | 100k | 09.01.2014  12:30:32 | 09.01.2014  13:55:47 | Good | HV=20V  I=2.9uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  49  
 | 
Thu Jan  9 14:07:31 2014 | 
Markus Friedl | AIDA | run | run041 | 100k | 09.01.2014  14:06:32 | 09.01.2014  15:33:13 | Good | HV=30V  I=3.3uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  51  
 | 
Thu Jan  9 16:36:30 2014 | 
Markus Friedl | AIDA | run | run042 | 100k | 09.01.2014  16:35:43 | 09.01.2014  18:02:17 | Good | HV=40V  I=3.4uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  52  
 | 
Thu Jan  9 18:09:40 2014 | 
Markus Friedl | AIDA | run | run044 | 100k | 09.01.2014  18:08:19 | 09.01.2014  19:35:21 | Good | HV=50V  I=3.6uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  53  
 | 
Thu Jan  9 19:37:33 2014 | 
Markus Friedl | AIDA | run | run045 | 100k | 09.01.2014  19:36:21 | 09.01.2014  21:01:31  | Good | HV=60V  I=3.8uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  54  
 | 
Thu Jan  9 21:41:20 2014 | 
Markus Friedl | AIDA | run | run046 | 100k | 09.01.2014  21:40:29 | 09.01.2014  23:07:16 | Good | HV=70V  I=3.8uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  55  
 | 
Thu Jan  9 23:27:27 2014 | 
Markus Friedl | AIDA | run | run047 | 100k | 09.01.2014  23:26:35 | 10.01.2014  00:52:56 | Good | HV=80V  I=3.8uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  57  
 | 
Fri Jan 10 08:21:46 2014 | 
Markus Friedl | AIDA | run | run049 | 100k | 10.01.2014  08:20:49  | 10.01.2014  09:49:46 | Good | HV=100V  I=4.2uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  58  
 | 
Fri Jan 10 09:54:11 2014 | 
Markus Friedl | AIDA | run | run050 | 100k | 10.01.2014  09:53:13 | 10.01.2014  11:21:12 | Good | HV=110V  I=4.1uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  60  
 | 
Fri Jan 10 11:26:54 2014 | 
Markus Friedl | AIDA | run | run051 | 100k | 10.01.2014  11:26:08 | 10.01.2014  12:53:12 | Good | HV=120V  I=4.6uA
 
centered position, HV scan
 
5GeV beam, 6 samples | 
   | 
| 
  61  
 | 
Fri Jan 10 13:04:49 2014 | 
Markus Friedl | AIDA | run | run052 | 100k | 10.01.2014  13:04:05 | 10.01.2014  14:30:18 | Good | HV=130V  I=4.6uA
 
centered position, HV scan
 