Tue Jan 7 20:26:50 2014, Markus Friedl, Infineon, run, run031, 200k, 07.01.2014 20:25:32, 07.01.2014 20:58:47, Good
|
HV=280V I=8.4uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 19:44:45 2014, Markus Friedl, Infineon, run, run030, 200k, 07.01.2014 19:43:35, 07.01.2014 20:11:03, Good
|
HV=270V I=8.6uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 19:12:07 2014, Markus Friedl, Infineon, run, run029, 200k, 07.01.2014 19:11:05, 07.01.2014 19:38:00, Good
|
HV=260V I=8.7uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 18:41:55 2014, Markus Friedl, Infineon, run, run028, 200k, 07.01.2014 18:40:40, 07.01.2014 19:07:32, Good
|
HV=250V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 18:11:52 2014, Markus Friedl, Infineon, run, run027, 200k, 07.01.2014 18:10:45, 07.01.2014 18:37:42, Good
|
HV=240V I=8.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 17:39:20 2014, Markus Friedl, Infineon, run, run026, 200k, 07.01.2014 17:38:01, 07.01.2014 18:05:11, Good
|
HV=230V I=8.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 17:09:56 2014, Markus Friedl, Infineon, run, run025, 200k, 07.01.2014 17:08:54, 07.01.2014 17:36:12, Good
|
HV=220V I=8.1uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 16:36:49 2014, Markus Friedl, Infineon, run, run024, 200k, 07.01.2014 16:35:44, 07.01.2014 17:03:10, Good
|
HV=210V I=8.1uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 15:54:22 2014, Markus Friedl, Infineon, run, run023, 200k, 07.01.2014 15:53:06, 07.01.2014 16:25:26, Good
|
HV=200V I=8.0uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 15:16:11 2014, Markus Friedl, Infineon, run, run022, 200k, 07.01.2014 15:15:09, 07.01.2014 15:42:17, Good
|
HV=150V I=7.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 14:51:45 2014, Thomas Bergauer, Belle SVD, TLU control, , , , , Unknown
|
1. ssh bastion
2. ssh belle-control
3. ssh telescope-admin@tb-aconite
(password telescope++)
dann:
How to generate trigger from TLU through FTSW to detector systems
2014.1.6 Mikihiko Nakao
* step 1 - open monitor window to show the FTSW status
[you@bastion03 ~]$ ssh telescope-admin@belle-rpc1
(still only limited people has access to b2daq account:
ask DAQ people or Katsuro Nakamura of SVD group)
[b2daq@belle-rpc1 ~]$ ssh telescope-admin@ttd10
[b2daq@ttd10 ~]$ statft -55 -i -c
(55 is the FTSW board-id, -i -c are to show the status repeatedly)
* step 2 - initialize FTSW to accept TLU trigger
[b2daq@ttd10 ~]$ trigft -55 tlu
* step 3 - start trigger at TLU
[you@bastion03 ~]$ ssh belle-rpc2
[you@belle-rpc2 ~]$ ssh telescope-admin@tb-aconite
(ask Alan Campbell or somebody for the password)
telescope-admin@tb-aconite:~$ cd eudaq-nakao/bin
...$ ./TLUControl.exe -a 4 -d 1 -i RJ45 -w 10 -n
here, -a option gives the possible trigger coincidence
(-a 1 --- dummy trigger generator from FTSW)
-a 2 --- trigger counter 1 only
-a 4 --- trigger counter 2 only
-a 8 --- trigger counter 3 only
-a 6 --- trigger counter 1 and 2
-a 10 --- trigger counter 1 and 3
-a 12 --- trigger counter 2 and 2
-a 14 --- trigger counter 1 and 2 and 3
other options are kept to be the same
-d 1 -i RJ45 --- connection to FTSW
-w 10 --- update frequency (10msec)
-n --- suppress messages
This gives you output like:
Status: 00,--,--,--,--,-- (0,0)
Scalers: 0, 7, 0, 0 <== from FTSW-dummy and trigger counters 1, 2, 3
Particles: 1
Triggers: 0 <== actual trigger to be distributed to FTSW
Entries: 0
TS errors: 0, 0 (redundancy, re-read)
Timestamp: 0x4f25a008 (1327865864) = 3.45791
Time: 3.463 s, Freq: 0 Hz, Average: 0 Hz
- |
Tue Jan 7 14:47:38 2014, Markus Friedl, Infineon, run, run021, 200k, 07.01.2014 14:46:08, 07.01.2014 15:13:23, Good
|
HV=100V I=7.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 13:20:48 2014, Markus Friedl, Infineon, run, run020, 300k, 07.01.2014 13:18:52, 07.01.2014 14:35:49, Good
|
HV=300V I=8.5uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
multi6 with same settings as run019 (htr+3)
Beam energy = 3 GeV |
Tue Jan 7 11:52:27 2014, Markus Friedl, Infineon, run, run019, 650k, 07.01.2014 11:47:24, 07.01.2014 13:15:21, Good
|
HV=300V I=9.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single sample run
Beam energy = 3 GeV |
Tue Jan 7 11:50:34 2014, Markus Friedl, Infineon, scan, run018x, 10k, 07.01.2014 11:xx:xx, 07.01.2014 11:xx:xx, Good
|
Delay scan with single sample
Several runs |
Tue Jan 7 09:33:51 2014, Thomas Bergauer, common, beam momentum back to 3Gev/c, run014 and later ones, , , , Unknown
|
|
Tue Jan 7 09:33:16 2014, Thomas Bergauer, , run, run017, 100k, 07.01.2014 09:31:45, 07.01.2014 09:52:58, Good
|
HV=300V I=9.08uA
position adapted to center beam better (+10mm horizonal)
DESY table z=-346 x=-255
3Gev/c |
Tue Jan 7 09:22:09 2014, Thomas Bergauer, , run, run016, 50k, 07.01.2014 09:19:10, 07.01.2014 09:30:03, Good
|
HV=290V I=9.00uA
position move back to original position (0mm/0mm) (not hitting the right APVs anymore)
DESY table z=-346 x=-255 |
Tue Jan 7 09:12:24 2014, Thomas Bergauer, Belle SVD, run, run015, 20k, 07.01.2014 09:10:52, 07.01.2014 09:15:39, Good
|
HV=290V I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
energy switched back to 3Gev/c |
Tue Jan 7 08:36:29 2014, Thomas Bergauer, Infineon, run, run014, 20k, 07.01.2014 08:34:06, 07.01.2014 09:05:47, Good
|
HV=290V I=9.55uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
6Gev/c,
bad strip region hardly hit |
|