| ID | 
Date | 
Author | 
Project | 
Subject | 
Run Number | 
Events  | 
StartTime | 
EndTime | 
Data | 
Text | 
  | 
| 
  31  
 | 
Tue Jan  7 16:36:49 2014 | 
Markus Friedl | Infineon | run | run024 | 200k | 07.01.2014  16:35:44 | 07.01.2014  17:03:10 | Good | HV=210V  I=8.1uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  32  
 | 
Tue Jan  7 17:09:56 2014 | 
Markus Friedl | Infineon | run | run025 | 200k | 07.01.2014  17:08:54 | 07.01.2014  17:36:12 | Good | HV=220V  I=8.1uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  33  
 | 
Tue Jan  7 17:39:20 2014 | 
Markus Friedl | Infineon | run | run026 | 200k | 07.01.2014  17:38:01 | 07.01.2014  18:05:11 | Good | HV=230V  I=8.2uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  34  
 | 
Tue Jan  7 18:11:52 2014 | 
Markus Friedl | Infineon | run | run027 | 200k | 07.01.2014  18:10:45 | 07.01.2014  18:37:42 | Good | HV=240V  I=8.2uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  35  
 | 
Tue Jan  7 18:41:55 2014 | 
Markus Friedl | Infineon | run | run028 | 200k | 07.01.2014  18:40:40 | 07.01.2014  19:07:32 | Good | HV=250V  I=8.3uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  36  
 | 
Tue Jan  7 19:12:07 2014 | 
Markus Friedl | Infineon | run | run029 | 200k | 07.01.2014  19:11:05 | 07.01.2014  19:38:00 | Good | HV=260V  I=8.7uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  37  
 | 
Tue Jan  7 19:44:45 2014 | 
Markus Friedl | Infineon | run | run030 | 200k | 07.01.2014  19:43:35 | 07.01.2014  20:11:03 | Good | HV=270V  I=8.6uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  38  
 | 
Tue Jan  7 20:26:50 2014 | 
Markus Friedl | Infineon | run | run031 | 200k | 07.01.2014  20:25:32 | 07.01.2014  20:58:47 | Good | HV=280V  I=8.4uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  39  
 | 
Tue Jan  7 21:02:58 2014 | 
Markus Friedl | Infineon | run | run032 | 200k | 07.01.2014  21:01:42 | 07.01.2014  21:29:03 | Good | HV=290V  I=8.3uA
 
position adapted to center beam better 
(+10mm horizontal) | 
   | 
| 
  83  
 | 
Wed Jan 29 12:07:48 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_003 | 200k | 28.01.2014 17:40 | 28.01.2014 18:20 | Good | HV at 150V; I at app. 9µA 3GeV, Single 
mode
 
  | 
   | 
| 
  84  
 | 
Wed Jan 29 12:08:52 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_004 | 200k | 28.01.2014 19:30 | 28.01.2014 20:00 | Good | HV at 200V; I at app. 9.5µA 3GeV, 
Single mode
 
  | 
   | 
| 
  85  
 | 
Wed Jan 29 12:10:06 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_005 | 200k | 28.01.2014 20:00 | 28.01.2014 23:00 | Good | HV at 210V; I at app. 8.5µA 3GeV, 
Single mode
 
  | 
   | 
| 
  86  
 | 
Wed Jan 29 12:11:00 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_006 | 200k | 28.01.2014 20:30 | 28.01.2014 21:00 | Good | HV at 220V; I at app. 8.5µA 3GeV, 
Single mode
 
  | 
   | 
| 
  87  
 | 
Wed Jan 29 21:55:09 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_007 | 200k | 29.01.2014 11:50 | 29.01.2014 12:15 | Good | HV at 230V; I at app. 8µA 3GeV, Single 
mode
 
  | 
   | 
| 
  88  
 | 
Wed Jan 29 21:56:15 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_008 | 200k | 29.01.2014 12:15 | 29.01.2014 12:45 | Good | HV at 240V; I at app. 7.5µA 3GeV, 
Single mode
 
  | 
   | 
| 
  91  
 | 
Wed Jan 29 21:59:51 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_011 | 200k | 29.01.2014 13:45 | 29.01.2014 14:20 | Good | HV at 270V; I at app. 7.6µA 3GeV, 
Single mode
 
  | 
   | 
| 
  92  
 | 
Wed Jan 29 22:01:08 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_012 | 200k | 29.01.2014 14:25 | 29.01.2014 15:26 | Good | HV at 280V; I at app. 8µA 3GeV, Single 
mode
 
  | 
   | 
| 
  93  
 | 
Wed Jan 29 22:02:04 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_013 | 200k | 29.01.2014 15:26 | 29.01.2014 17:00 | Good | HV at 290V; I at app. 8µA 3GeV, Single 
mode
 
  | 
   | 
| 
  94  
 | 
Wed Jan 29 22:03:15 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_014 | 200k | 29.01.2014 18:15 | 29.01.2014 18:45 | Good | HV at 260V; I at app. 7.5µA 3GeV, 
Single mode
 
  | 
   | 
| 
  95  
 | 
Wed Jan 29 22:06:12 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_015 | 200k | 29.01.2014 19:15 | 29.01.2014 19:45 | Good | HV at 300V; I at app. 7.5µA 3GeV, 
Single mode
 
  | 
   |