Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 2 of 5  Not logged in ELOG logo
Entry  Wed Jan 29 12:10:06 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_005, 200k, 28.01.2014 20:00, 28.01.2014 23:00, Good 
HV at 210V; I at app. 8.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 12:11:00 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_006, 200k, 28.01.2014 20:30, 28.01.2014 21:00, Good 
HV at 220V; I at app. 8.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:55:09 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_007, 200k, 29.01.2014 11:50, 29.01.2014 12:15, Good 
HV at 230V; I at app. 8µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:56:15 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_008, 200k, 29.01.2014 12:15, 29.01.2014 12:45, Good 
HV at 240V; I at app. 7.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:56:58 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_009, 110k, 29.01.2014 12:50, 29.01.2014 13:15, Good 
HV at 250V; I at app. 7.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:57:55 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_010, 100k, 29.01.2014 13:20, 29.01.2014 13:35, Good 
HV at 260V; I at app. 7.6µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:59:51 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_011, 200k, 29.01.2014 13:45, 29.01.2014 14:20, Good 
HV at 270V; I at app. 7.6µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:01:08 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_012, 200k, 29.01.2014 14:25, 29.01.2014 15:26, Good 
HV at 280V; I at app. 8µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:02:04 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_013, 200k, 29.01.2014 15:26, 29.01.2014 17:00, Good 
HV at 290V; I at app. 8µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:03:15 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_014, 200k, 29.01.2014 18:15, 29.01.2014 18:45, Good 
HV at 260V; I at app. 7.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:06:12 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_015, 200k, 29.01.2014 19:15, 29.01.2014 19:45, Good 
HV at 300V; I at app. 7.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 22:08:48 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, , , 29.01.2014 22:00, 29.01.2014 22:00, Good 
All Infineon Stack 2 runs have been taken at table position: 1.089030, -12.800610
 
Entry  Wed Jan 29 22:36:35 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_pos1_001, 200k, 29.01.2014 22:15, 29.01.2014 22:35, Good 
HV at 300V; I at app. 7.5µA 3GeV, Single mode
Position changed to -3.910970 -17.800610
 
Entry  Wed Jan 29 22:40:09 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_pos2_002, 200k, 29.01.2014 22:40, 29.01.2014 23:15, Good 
HV at 300V; I at app. 7.5µA 3GeV, Single mode
Position changed to --8.91097 -22.80061
 
Entry  Tue Jan 7 14:51:45 2014, Thomas Bergauer, Belle SVD, TLU control, , , , , Unknown 
1. ssh bastion
2. ssh belle-control
3. ssh telescope-admin@tb-aconite
Entry  Tue Jan 7 02:17:14 2014, Thomas Bergauer, , beam momentum 6GeV/c, run013, , , , Unknown 
 
Entry  Tue Jan 7 09:33:51 2014, Thomas Bergauer, common, beam momentum back to 3Gev/c, run014 and later ones, , , , Unknown 
 
Entry  Sat Jan 4 16:30:46 2014, Markus Friedl, Infineon, cal, cal001, 83800, 04.01.2014 16:16:51, 04.01.2014 16:25:46, Good 
HV=300V  I=9.3uA  (total)
Entry  Sun Jan 5 15:08:09 2014, Markus Friedl, AIDA, cal, cal002, 83800, 05.01.2014 15:01:32, 05.01.2014 15:30:36, Good 
HV=100V  I=6uA
Entry  Thu Jan 9 10:10:31 2014, Markus Friedl, AIDA, cal, cal038, 83800, 09.01.2014 10:09:27, 09.01.2014 10:38:23, Good 
HV=100V  I=4.2uA
centered position
5GeV beam, single sample
ELOG V3.1.5-fc6679b