Thu Jan 9 19:37:33 2014, Markus Friedl, AIDA, run, run045, 100k, 09.01.2014 19:36:21, 09.01.2014 21:01:31 , Good
|
HV=60V I=3.8uA
centered position, HV scan
5GeV beam, 6 samples |
Thu Jan 9 21:41:20 2014, Markus Friedl, AIDA, run, run046, 100k, 09.01.2014 21:40:29, 09.01.2014 23:07:16, Good
|
HV=70V I=3.8uA
centered position, HV scan
5GeV beam, 6 samples |
Thu Jan 9 23:27:27 2014, Markus Friedl, AIDA, run, run047, 100k, 09.01.2014 23:26:35, 10.01.2014 00:52:56, Good
|
HV=80V I=3.8uA
centered position, HV scan
5GeV beam, 6 samples |
Fri Jan 10 08:21:46 2014, Markus Friedl, AIDA, run, run049, 100k, 10.01.2014 08:20:49 , 10.01.2014 09:49:46, Good
|
HV=100V I=4.2uA
centered position, HV scan
5GeV beam, 6 samples |
Fri Jan 10 09:54:11 2014, Markus Friedl, AIDA, run, run050, 100k, 10.01.2014 09:53:13, 10.01.2014 11:21:12, Good
|
HV=110V I=4.1uA
centered position, HV scan
5GeV beam, 6 samples |
Fri Jan 10 11:26:54 2014, Markus Friedl, AIDA, run, run051, 100k, 10.01.2014 11:26:08, 10.01.2014 12:53:12, Good
|
HV=120V I=4.6uA
centered position, HV scan
5GeV beam, 6 samples |
Fri Jan 10 13:04:49 2014, Markus Friedl, AIDA, run, run052, 100k, 10.01.2014 13:04:05, 10.01.2014 14:30:18, Good
|
HV=130V I=4.6uA
centered position, HV scan
5GeV beam, 6 samples |
Sat Jan 11 20:56:29 2014, Markus Friedl, AIDA, run, run053, 100k, 11.01.2014 20:55:29, 11.01.2014 22:25:43, Good
|
HV=140V I=7.1uA
centered position, HV scan
5GeV beam, 6 samples |
Wed Jan 29 12:02:52 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_001, 100k, 28.01.2014 16:30, 28.01.2014 16:50, Good
|
HV at 0V; I at app. 5nA 3GeV, Single mode
|
Wed Jan 29 21:57:55 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_010, 100k, 29.01.2014 13:20, 29.01.2014 13:35, Good
|
HV at 260V; I at app. 7.6µA 3GeV, Single mode
|
Tue Jan 7 11:50:34 2014, Markus Friedl, Infineon, scan, run018x, 10k, 07.01.2014 11:xx:xx, 07.01.2014 11:xx:xx, Good
|
Delay scan with single sample
Several runs |
Wed Jan 29 21:56:58 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_009, 110k, 29.01.2014 12:50, 29.01.2014 13:15, Good
|
HV at 250V; I at app. 7.5µA 3GeV, Single mode
|
Sun Jan 26 19:14:07 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2, HW_Run_Infineon_Stack2_003, 140 k, 26.01.2014 18:10, 26.01.2014 19:15, Good
|
HV at 300V; I at app. 10µA 5GeV, Single mode
|
Wed Jan 29 12:04:53 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_002, 140k, 28.01.2014 16:50, 28.01.2014 17:20, Good
|
HV at 100V; I at app. 8.5µA 3GeV, Single mode
|
Tue Jan 7 00:36:03 2014, Markus Friedl, Infineon, run, run012, 190k, 07.01.2014 00:33:58, 07.01.2014 02:12:32 , Good
|
HV=150V I=8.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 16:33:13 2014, Markus Friedl, Infineon, run, run001, 200k, 06.01.2014 16:28:58, 06.01.2014 17:10:56, Good
|
HV=300V I=11.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 17:17:47 2014, Markus Friedl, Infineon, run, run002, 200k, 06.01.2014 17:14:39, 06.01.2014 18:00:34, Good
|
HV=100V I=8.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 18:06:16 2014, Markus Friedl, Infineon, run, run003, 200k, 06.01.2014 18:04:14, 06.01.2014 18:44:15, Good
|
HV=200V I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 18:49:00 2014, Markus Friedl, Infineon, run, run004, 200k, 06.01.2014 18:47:38, 06.01.2014 19:27:33, Good
|
HV=250V I=9.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
Mon Jan 6 19:31:44 2014, Markus Friedl, AIDA, run, run005, 200k, 06.01.2014 19:29:52, 06.01.2014 20:09:59, Good
|
HV=230V I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255 |
|