ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
17
|
Tue Jan 7 02:17:14 2014 |
Thomas Bergauer | | beam momentum 6GeV/c | run013 | | | | Unknown |
|
21
|
Tue Jan 7 09:22:09 2014 |
Thomas Bergauer | | run | run016 | 50k | 07.01.2014 09:19:10 | 07.01.2014 09:30:03 | Good |
HV=290V I=9.00uA
position move back to original position (0mm/0mm) (not hitting the right APVs anymore)
DESY table z=-346 x=-255 |
22
|
Tue Jan 7 09:33:16 2014 |
Thomas Bergauer | | run | run017 | 100k | 07.01.2014 09:31:45 | 07.01.2014 09:52:58 | Good |
HV=300V I=9.08uA
position adapted to center beam better (+10mm horizonal)
DESY table z=-346 x=-255
3Gev/c |
69
|
Thu Jan 23 22:47:49 2014 |
Hao Yin | | AIDA | CalibrationRun001 | 83800 | 23.01.2014 13:35:55 | 23.01.2014 02:08:15 | Good |
taken with tuxdaq...
HV=75V I=?3.7uA?
position = 0 / -30 mm relative to initial (but again centered) ?
?5GeV beam, single sample? (software trigger run)
?narrow timing (trigger width)? |
70
|
Fri Jan 24 00:21:16 2014 |
Hao Yin | | AIDA | HW_AIDA001 | 40k | 24.02.2014 00:18 | | Unknown |
HV=100V I=3.7uA
position = 0 / -30 mm relative to initial (but again centered) no idea ---
3GeV beam, multipeak 6 samples
???narrow timing (trigger width)??? no idea ... |
72
|
Fri Jan 24 11:23:15 2014 |
Hao Yin | | AIDA | HW_AIDA003 | 76356 | 24.02.2014 10:30 | 24.02.2014 11:22 | Unknown |
HV=100V I=3.7uA
position = 0 / -30 mm relative to initial (but again centered) no idea ---
3GeV beam, multipeak 6 samples
???narrow timing (trigger width)??? no idea ... |
2
|
Sun Jan 5 15:08:09 2014 |
Markus Friedl | AIDA | cal | cal002 | 83800 | 05.01.2014 15:01:32 | 05.01.2014 15:30:36 | Good |
HV=100V I=6uA |
8
|
Mon Jan 6 19:31:44 2014 |
Markus Friedl | AIDA | run | run005 | 200k | 06.01.2014 19:29:52 | 06.01.2014 20:09:59 | Good |
HV=230V I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
3 GeV beam momentum |
41
|
Wed Jan 8 12:40:30 2014 |
Thomas Bergauer | AIDA | intcal AIDA Stack | cal034 | 83.8k | 08.01.2014 12:32:22 | 08.01.2014 13:01:30 | Unknown |
HV=100V I=4.5uA
position adapted to center beam
|
42
|
Wed Jan 8 14:10:07 2014 |
Thomas Bergauer | AIDA | run | run035 | 211681 | 08.01.2014 14:01:25 | 08.01.2014 17:03:55 | Unknown |
HV=100V I=4.2uA
position adapted to center beam
accidentally hit reset button on PC which ended this run abruptly...
5 GeV beam |
43
|
Wed Jan 8 17:20:40 2014 |
Markus Friedl | AIDA | run | run036 | 320k | 08.01.2014 17:18:51 | 08.01.2014 22:14:58 | Unknown |
HV=100V I=4.3uA
centered position
5GeV beam
narrow timing (trigger width), but 6 samples
|
44
|
Wed Jan 8 22:19:11 2014 |
Markus Friedl | AIDA | run | run037 | 1.2M | 08.01.2014 22:18:30 | 09.01.2014 10:08:14 | Good |
HV=100V I=4.4uA
centered position
5GeV beam, single sample
narrow timing (trigger width)
|
45
|
Thu Jan 9 10:10:31 2014 |
Markus Friedl | AIDA | cal | cal038 | 83800 | 09.01.2014 10:09:27 | 09.01.2014 10:38:23 | Good |
HV=100V I=4.2uA
centered position
5GeV beam, single sample
narrow timing (trigger width) |
46
|
Thu Jan 9 11:02:14 2014 |
Markus Friedl | AIDA | info | | | | | Unknown |
Created bad strip masks for the AIDA config files |
47
|
Thu Jan 9 11:04:34 2014 |
Markus Friedl | AIDA | run | run039 | 100k | 09.01.2014 11:02:36 | 09.01.2014 12:28:41 | Good |
HV=10V I=2.1uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
48
|
Thu Jan 9 12:31:29 2014 |
Markus Friedl | AIDA | run | run040 | 100k | 09.01.2014 12:30:32 | 09.01.2014 13:55:47 | Good |
HV=20V I=2.9uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
49
|
Thu Jan 9 14:07:31 2014 |
Markus Friedl | AIDA | run | run041 | 100k | 09.01.2014 14:06:32 | 09.01.2014 15:33:13 | Good |
HV=30V I=3.3uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
51
|
Thu Jan 9 16:36:30 2014 |
Markus Friedl | AIDA | run | run042 | 100k | 09.01.2014 16:35:43 | 09.01.2014 18:02:17 | Good |
HV=40V I=3.4uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|
52
|
Thu Jan 9 18:09:40 2014 |
Markus Friedl | AIDA | run | run044 | 100k | 09.01.2014 18:08:19 | 09.01.2014 19:35:21 | Good |
HV=50V I=3.6uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
MOVED TIMING by 1 clock (now signal is centered again) |
53
|
Thu Jan 9 19:37:33 2014 |
Markus Friedl | AIDA | run | run045 | 100k | 09.01.2014 19:36:21 | 09.01.2014 21:01:31 | Good |
HV=60V I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)
|