Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 1 of 5  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events StartTime EndTimedown Data Text Attachments
  98   Wed Jan 29 22:40:09 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_pos2_002200k29.01.2014 22:4029.01.2014 23:15GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
Position changed to --8.91097 -22.80061
  
  97   Wed Jan 29 22:36:35 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_pos1_001200k29.01.2014 22:1529.01.2014 22:35GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
Position changed to -3.910970 -17.800610
  
  96   Wed Jan 29 22:08:48 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias Scan  29.01.2014 22:0029.01.2014 22:00GoodAll Infineon Stack 2 runs have been taken
at table position: 1.089030, -12.800610
 
  
  95   Wed Jan 29 22:06:12 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_015200k29.01.2014 19:1529.01.2014 19:45GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
 
  
  94   Wed Jan 29 22:03:15 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_014200k29.01.2014 18:1529.01.2014 18:45GoodHV at 260V; I at app. 7.5µA 3GeV,
Single mode
 
  
  93   Wed Jan 29 22:02:04 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_013200k29.01.2014 15:2629.01.2014 17:00GoodHV at 290V; I at app. 8µA 3GeV, Single
mode
 
  
  92   Wed Jan 29 22:01:08 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_012200k29.01.2014 14:2529.01.2014 15:26GoodHV at 280V; I at app. 8µA 3GeV, Single
mode
 
  
  91   Wed Jan 29 21:59:51 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_011200k29.01.2014 13:4529.01.2014 14:20GoodHV at 270V; I at app. 7.6µA 3GeV,
Single mode
 
  
  90   Wed Jan 29 21:57:55 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_010100k29.01.2014 13:2029.01.2014 13:35GoodHV at 260V; I at app. 7.6µA 3GeV,
Single mode
 
  
  89   Wed Jan 29 21:56:58 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_009110k29.01.2014 12:5029.01.2014 13:15GoodHV at 250V; I at app. 7.5µA 3GeV,
Single mode
 
  
  88   Wed Jan 29 21:56:15 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_008200k29.01.2014 12:1529.01.2014 12:45GoodHV at 240V; I at app. 7.5µA 3GeV,
Single mode
 
  
  87   Wed Jan 29 21:55:09 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_007200k29.01.2014 11:5029.01.2014 12:15GoodHV at 230V; I at app. 8µA 3GeV, Single
mode
 
  
  85   Wed Jan 29 12:10:06 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_005200k28.01.2014 20:0028.01.2014 23:00GoodHV at 210V; I at app. 8.5µA 3GeV,
Single mode
 
  
  86   Wed Jan 29 12:11:00 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_006200k28.01.2014 20:3028.01.2014 21:00GoodHV at 220V; I at app. 8.5µA 3GeV,
Single mode
 
  
  84   Wed Jan 29 12:08:52 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_004200k28.01.2014 19:3028.01.2014 20:00GoodHV at 200V; I at app. 9.5µA 3GeV,
Single mode
 
  
  83   Wed Jan 29 12:07:48 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_003200k28.01.2014 17:4028.01.2014 18:20GoodHV at 150V; I at app. 9µA 3GeV, Single
mode
 
  
  82   Wed Jan 29 12:04:53 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_002140k28.01.2014 16:5028.01.2014 17:20GoodHV at 100V; I at app. 8.5µA 3GeV,
Single mode
 
  
  81   Wed Jan 29 12:02:52 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_001100k28.01.2014 16:3028.01.2014 16:50GoodHV at 0V; I at app. 5nA 3GeV, Single mode
 
  
  80   Mon Jan 27 12:20:53 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2HW_Run_Infineon_Stack2_004800k27.01.2014 09:1027.01.2014 12:15GoodHV at 300V; I at app. 10µA 3GeV,
Single mode
 
  
  79   Sun Jan 26 19:14:07 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2HW_Run_Infineon_Stack2_003140 k26.01.2014 18:1026.01.2014 19:15GoodHV at 300V; I at app. 10µA 5GeV,
Single mode
 
  
ELOG V3.1.5-fc6679b