89
Entry time:
Tue Oct 24 18:18:11 2017
Author:
Peter Paulitsch
DUT:
HPK_3e14
Subject:
run000296
Run Number:
296
Events:
600000
XYPosition:
30°
Cooling:
Yes
Data:
Good
Parameter
Value
Alibava filename
run000296.dat
Telescope filename
run000296.raw
Pedestal filename
KIT_pedestal_600V_22102017.ped
Bias voltage
-600 V
Dark current
34 uA
Sensor temperature
-24,5°C
Latency
140 [a.u.]
Alibava triggers
600000
Telescope triggers
600000
Data synced
yes
Table position x/y
Region of interest
bias line
Trigger frequency
100 Hz
Meas. time
100min
Beam energy
5.6 GeV
Cooling
yes
Alibava efficiency
44,5%
ELOG V3.1.5-fc6679b