Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter) |
Not logged in |
 |
|
Message ID: 127
Entry time: Mon Oct 30 11:54:14 2017
|
Author: |
Peter Paulitsch |
DUT: |
IFX_200_1e15 |
Subject: |
run000377 |
Run Number: |
377 |
Events: |
1010000 |
XYPosition: |
76.50, 66.00, -10° |
Cooling: |
Yes |
Data: |
Good |
|
|
Parameter |
Value |
Alibava filename |
run000377.dat |
Telescope filename |
run000377.raw |
Pedestal filename |
KIT_pedestal_600V_26102017.ped |
Bias voltage |
-600 V |
Dark current |
|
Sensor temperature |
|
Latency |
140 [a.u.] |
Alibava triggers |
1010000 |
Telescope triggers |
1000000 |
Data synced |
yes |
Table position x/y |
76.50, 66.00 |
Region of interest |
bias line |
Trigger frequency |
|
Meas. time |
|
Beam energy |
5.6 GeV |
Cooling |
yes |
Alibava efficiency |
33.7% |
|