Sun Apr 16 19:04:41 2017, Axel Koenig, ALiBaVa (IFX), run_012_Baby_60V.dat, 012, 135000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 589. Bias scan 60 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_012_Baby_60V.dat |
Telescope run |
589 |
Triggers |
135000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-60 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Sun Apr 16 19:46:01 2017, Axel Koenig, ALiBaVa (IFX), run_013_Baby_65V.dat, 013, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 590. Bias scan 65 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_013_Baby_65V.dat |
Telescope run |
590 |
Triggers |
112000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-65 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Sun Apr 16 20:22:27 2017, Axel Koenig, ALiBaVa (IFX), run_014_Baby_70V.dat, 014, 250000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 591. Bias scan 70 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_014_Baby_70V.dat |
Telescope run |
591 |
Triggers |
250000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-70 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Sun Apr 16 21:43:15 2017, Axel Koenig, ALiBaVa (IFX), run_015_Baby_100V.dat, 015, 2500000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 592. Long run, bias voltage 100 V. Long run finished without any problems.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_015_Baby_100V.dat |
Telescope run |
592 |
Triggers |
2500000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Sun Apr 16 22:42:51 2017, Johannes Grossmann, MaPSA, HV_Scan, 387, 0, 0, No, Unknown
|
Changed HV from 100V to 80 V
22:41 16.4.2017 |
Mon Apr 17 08:14:24 2017, Axel Koenig, ALiBaVa (IFX), run_016_Baby_75V.dat, 016, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 593. Bias scan 75 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_016_Baby_75V.dat |
Telescope run |
593 |
Triggers |
112000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-75 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 09:01:09 2017, Axel Koenig, ALiBaVa (IFX), run_017_Baby_80V.dat, 017, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 594. Bias scan 80 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_017_Baby_80V.dat |
Telescope run |
594 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-80 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 09:04:02 2017, Axel Koenig, ALiBaVa (IFX), run_006_Baby_100V.dat, 006, k.a., 102.5, 22.5, 230, No, Unknown
|
Remarks: Telescope run 570. Telescope chiller turned off (could be the root cause of runs crashing).
Forgot ro record data in elog.
Parameter |
Value |
Alibava run |
run_006_Baby_100V.dat |
Telescope run |
570 |
Triggers |
k.a. |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
230 deg
|
|
Mon Apr 17 09:29:40 2017, Axel Koenig, ALiBaVa (IFX), run_018_Baby_90V.dat, 018, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 595. Bias scan 90 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_018_Baby_90V.dat |
Telescope run |
595 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-90 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 10:05:57 2017, Axel Koenig, ALiBaVa (IFX), run_019_Baby_110V.dat, 019, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 596. Bias scan 110 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_019_Baby_110V.dat |
Telescope run |
596 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-110 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 10:10:33 2017, Johannes Grossmann, MaPSA, HV_Scan, 387, 0, 0, No, Unknown
|
Changed HV from 80 V to 60 V
Not in condition data applied in the settings
10:08 17.4.2017 |
Mon Apr 17 10:14:15 2017, Axel Koenig, common, Run summary Baby, , , , No, Unknown
|
Alibava run |
Telescope run |
File existence check |
Run type |
Triggers |
Remarks |
001 |
562 |
yes |
first run |
250000 |
none |
002 |
563 |
yes |
central position shifted by -1 cm vertically |
250000 |
none |
003 |
564 |
yes |
central position shifted by + 1cm |
250000 |
none |
004 |
565 |
yes |
central position angle +10 deg |
250000 |
none |
005 |
568 |
yes |
central position angle -10 deg |
250000 |
none |
006 |
570 |
yes |
unknown (maybe long run over night that crashed) |
? |
data may be corrupted |
007 |
579 |
yes |
bias scan -10V |
450000 |
run crashed data only valid up to 274915 |
008 |
583 |
yes |
bias scan -20V |
175000 |
none |
009 |
586 |
yes |
bias scan -30V |
135000 |
none |
010 |
587 |
yes |
bias scan -40V |
135000 |
none |
011 |
588 |
yes |
bias scan -50V |
135000 |
none |
012 |
589 |
yes |
bias scan -60V |
135000 |
none |
013 |
590 |
yes |
bias scan -65V |
112000 |
none |
014 |
591 |
yes |
bias scan -70V |
112000 |
none |
015 |
592 |
yes |
long run over night |
2500000 |
none |
016 |
593 |
yes |
bias scan -75V |
112000 |
none |
017 |
594 |
yes |
bias scan -80V |
112000 |
none |
018 |
595 |
yes |
bias scan -90V |
112000 |
none |
019 |
596 |
yes |
bias scan -110V |
112000 |
none |
020 |
597 |
yes |
bias scan -120V |
112000 |
none |
021 |
598 |
yes |
bias scan -130V |
112000 |
none |
022 |
599 |
yes |
bias scan -140V |
112000 |
none |
023 |
600 |
yes |
bias scan -150V |
112000 |
none |
Central beam position: x = 102 mm, y = 22.5 mm, rot = 240 deg
Current was stable for all runs i.e. 500 +- 10 nA at 100 V
Trigger efficiency ~ 90% for all runs (except bias scan).
Temperature in area 20+-1 deg.
Telescope chiller off for all runs. |
Mon Apr 17 10:36:22 2017, Axel Koenig, ALiBaVa (IFX), run_020_Baby_120V.dat, 020, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 597. Bias scan 120 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_020_Baby_120V.dat |
Telescope run |
597 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-120 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 11:04:40 2017, Axel Koenig, ALiBaVa (IFX), run_021_Baby_130V.dat, 021, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 598. Bias scan 130 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_021_Baby_130V.dat |
Telescope run |
598 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-130 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 11:34:55 2017, Axel Koenig, ALiBaVa (IFX), run_022_Baby_140V.dat, 022, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 599. Bias scan 140 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_022_Baby_140V.dat |
Telescope run |
599 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-140 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 12:06:11 2017, Axel Koenig, ALiBaVa (IFX), run_023_Baby_150V.dat, 023, 112000, 102.5, 22.5, 240, No, Unknown
|
Remarks: Telescope run 600. Bias scan 150 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_023_Baby_150V.dat |
Telescope run |
600 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-150 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 12:26:33 2017, Johannes Grossmann, MaPSA, HV_Scan, 456, 0, 0, No, Unknown
|
Changed HV from 60 V to 120 V
12:24 17.4.2017 |
Mon Apr 17 13:30:01 2017, Axel Koenig, ALiBaVa (IFX), run_001_HPK_CB_200V.dat, 001, 450000, 107, 0, 240, No, Unknown
|
Remarks: Telescope run 604. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_001_HPK_CB_200V.dat |
Telescope run |
604 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
0 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 16:36:56 2017, Axel Koenig, ALiBaVa (IFX), run_002_HPK_CB_200V.dat, 002, 450000, 107, 5.8, 240, No, Unknown
|
Remarks: Telescope run 605. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_HPK_CB_200V.dat |
Telescope run |
605 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
5.8 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 17:02:34 2017, Axel Koenig, ALiBaVa (IFX), run_003_HPK_CB_200V.dat, 003, 250000, 107, 2.6, 230, No, Unknown
|
Remarks: Telescope run 606. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_HPK_CB_200V.dat |
Telescope run |
606 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
230 deg
|
|
|