Mon Nov 30 17:23:51 2015, Hao Yin, Belle II, system, HardwareRun001,
|
ADC Hot, FIRRun001, PedestalRun001
room temp pedrun
target: BW |
Mon Nov 30 17:47:54 2015, Hao Yin, Belle II, system, HardwareRun002,
|
ADC Hot, FIRRun001, PedestalRun001
target: -Z
room temp pedrun
|
Mon Nov 30 18:32:13 2015, Hao Yin, Belle II, system, ADC Delay Scan Cold,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns) |
Mon Nov 30 18:44:04 2015, Hao Yin, Belle II, system, FIRRun_Cold,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns)
|
Mon Nov 30 18:45:49 2015, Hao Yin, Belle II, system, PedestalRun_Cold,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001
|
Mon Nov 30 18:49:23 2015, Hao Yin, Belle II, system, Hardware_Cold,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001
target: -Z
|
Mon Nov 30 19:01:54 2015, Hao Yin, Belle II, system, Hardware_Cold,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001
Temp = 0°C
target: CE
|
Mon Nov 30 19:48:05 2015, Hao Yin, Belle II, system, Hardware_Room_With_Cold_I2C,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001
with room temp i2c config
Temp = 0°C
target: CE
|
Mon Nov 30 20:06:15 2015, Hao Yin, Belle II, system, Hardware_Room_With_Cold_I2C,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001
with room temp i2c config
Temp = room
target: -Z
|
Mon Nov 30 20:16:37 2015, Hao Yin, Belle II, system, Hardware_Room_With_Cold_I2C,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001
ADC delay shifted by 3 (1.5ns) all sensors
with room temp i2c config
Temp = room
target: -Z
|
Mon Nov 30 20:27:42 2015, Hao Yin, Belle II, system, Hardware_Room_With_Cold_I2C,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001
ADC shifted by 5 (2.5ns) all sensors
with room temp i2c config
Temp = room
target: -Z
Note : n-side (strip nr 200 - 220 shadowhits) |
Mon Nov 30 22:35:41 2015, Hao Yin, Belle II, system, Hardware_Room_With_Cold_I2C,
|
ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001
ADC shifted by 9 (4.5ns) all sensors
with room temp i2c config
Temp = room
target: -Z |
Fri Apr 18 17:23:26 2008, Markus Friedl, SPS Testbeam June08, hybrid, hybrid 01, Noise of hybrid 01, sensor fully bonded, no HV
|
HV bias not yet glued to backplane |
Tue Apr 22 19:34:09 2008, Markus Friedl, SPS Testbeam June08, module, hybrid 01, Properties of hybrid 01, sensor fully bonded, HV=100V 6x
|
HV bias glued to backplane, HV=100V |
Wed Apr 23 13:05:05 2008, Christian Irmler, SPS Testbeam June08, source, hybrid 01, time correlation between TDC and sensor measurement -> 3.1 ns RMS
|
|
Wed Apr 23 13:37:18 2008, Markus Friedl, SPS Testbeam June08, source, hybrid 01, analysis results of source test
|
Ignore the "KEK November 2007" title - that's a legacy and is already changed :-)
As of now, there is no distinction in 16 separate zones. However, the gaps between the the zones are clearly visible in the Hit Profile, as the edge strips on both sides have a larger sensitive area and thus collect more hits than other strips; hence the spikes in the (otherwise pretty gaussian) beam profile. There is a single strip with no entries in the center - that's the one that suffered from the bias bond repair action.
SNR=21 (peak mode) is pretty healthy and fits to similar detectors operated with APV25.
All data was taken in multi-peak mode with subsequent hit fitting to obtain amplitude and timing (see separate posting for timing precision).
The verbose output of the analysis is pasted below.
Analysis of vie_run001
Peak Mode, 3 x 200 initevents (first 10 skipped) + 99400 events
Number hybrids: 1 number zones: 2 number sensors: 1
Using calibration file vie_cal001
No pedestal correction file
Seed/Neighbor/Cluster/Noisy Strips Cuts [RMS noise]: 5.0/3.0/5.0
Min. hitlength: 3
Comments:
SILC module 01
HV=100V, 40MHz, Tp=50ns, 30ns
Sr90 1mCi , black cloth cover
Analysis date: 23.04.2008 13:25:09
Analysis settings:
runname: vie_run001_cluster
clock: 40.00 MHz
datafilepath: data/
outputpath: output/
subevents: 6
fitmode: 2 (cal. fit)
options: h
Results:
ModuleName ZoneType Ch OKCh OK% Entries MClW MPSignal Noise MPSNR HpSE Occup
p_side JP single sensor 256 256 100.0 90385 2.53 21546.1 729.4 20.68 0.53 1.81 |
Wed May 7 15:24:49 2008, Christian Irmler, SPS Testbeam June08, module, module 10/02, properties (noise, intcal), APVs bonded to the sensor 12x
|
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100V) = 19.1 nA
Ibias (200V) = 23.7 nA |
Wed May 7 15:26:24 2008, Christian Irmler, SPS Testbeam June08, module, module 20/09, properties (noise, intcal), APVs bonded to the sensor 12x
|
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 25.1 nA
Ibias (200 V) = 31.4 nA |
Wed May 7 15:40:07 2008, Christian Irmler, SPS Testbeam June08, module, module 07/07, properties (noise, intcal), APVs bonded to the sensor 12x
|
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 20.2 nA
Ibias (200 V) = 21.9 nA |
Wed May 7 16:12:58 2008, Christian Irmler, SPS Testbeam June08, module, module 12/08, properties (noise, intcal), APVs bonded to the sensor 12x
|
Module tested with 1 and 2 rows bonded to the sensor, respectively.
HV = 100 V
Ibias (100 V) = 22.2 nA
Ibias (200 V) = 26.5 nA |
|