Home CMS Production Clean room MedAustron HEPHY testbeams old
electronics module assembly SiDDaTA scratch
  HEPHY logbook of the Electronics Group, Page 2 of 4  Not logged in ELOG logo
ID Date Authordown Project Measurement Type Object ID Subject
  52   Mon Nov 30 15:18:12 2015 Hao YinBelle IImoduleADC_DELAY_HOTADC delay hot

ADC delay scan at room temp and 20 min after APV I2C config.

measured values at display in the FIR_HOT cfg file.

17:06 first run 20 min after i2c config.

  53   Mon Nov 30 17:11:17 2015 Hao YinBelle IImoduleFIRRun001FIRRun001 aft ADC_HOT

FirRun 20 min after I2C

  54   Mon Nov 30 17:13:47 2015 Hao YinBelle IIsystemPedestalRun 

ADC Hot, FIRRun001

room temp pedrun

  55   Mon Nov 30 17:23:51 2015 Hao YinBelle IIsystemHardwareRun001 

ADC Hot, FIRRun001, PedestalRun001

room temp pedrun

target: BW

  56   Mon Nov 30 17:47:54 2015 Hao YinBelle IIsystemHardwareRun002 

ADC Hot, FIRRun001, PedestalRun001

target: -Z

room temp pedrun

 

  57   Mon Nov 30 18:32:13 2015 Hao YinBelle IIsystemADC Delay Scan Cold 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns)

  58   Mon Nov 30 18:44:04 2015 Hao YinBelle IIsystemFIRRun_Cold 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns)

 

  59   Mon Nov 30 18:45:49 2015 Hao YinBelle IIsystemPedestalRun_Cold 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001

 

  60   Mon Nov 30 18:49:23 2015 Hao YinBelle IIsystemHardware_Cold 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001

target: -Z

 

  61   Mon Nov 30 19:01:54 2015 Hao YinBelle IIsystemHardware_Cold 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001

Temp = 0°C

target: CE

 

  62   Mon Nov 30 19:48:05 2015 Hao YinBelle IIsystemHardware_Room_With_Cold_I2C 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001

with room temp i2c config

Temp = 0°C

target: CE

 

  63   Mon Nov 30 20:06:15 2015 Hao YinBelle IIsystemHardware_Room_With_Cold_I2C 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001

with room temp i2c config

Temp = room

target: -Z

 

  64   Mon Nov 30 20:16:37 2015 Hao YinBelle IIsystemHardware_Room_With_Cold_I2C 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001

ADC delay shifted by 3 (1.5ns) all sensors

with room temp i2c config

Temp = room

target: -Z

 

  65   Mon Nov 30 20:27:42 2015 Hao YinBelle IIsystemHardware_Room_With_Cold_I2C 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001

ADC shifted by 5 (2.5ns) all sensors

with room temp i2c config

Temp = room

target: -Z

Note : n-side (strip nr 200 - 220 shadowhits)

  67   Mon Nov 30 22:35:41 2015 Hao YinBelle IIsystemHardware_Room_With_Cold_I2C 

ADC Cold diff to hot: 1-3 adc delay config (max 1.5 ns), FIRRun_Cold_001

ADC shifted by 9 (4.5ns) all sensors

with room temp i2c config

Temp = room

target: -Z

  15   Wed Oct 7 14:23:35 2009 Dieter UhlBELLE Upgradehybrid#4hybrid-pitchadapter

opens at upper coat

pitchadapter4_upper_coat_opens.gif

 

shorts at upper coat

pitchadapter4_upper_coat.gif

 

opens at lower coat

pitchadapter4_lower_coat_opens.gif

 

shorts at lower coat

pitchadapter4_lower_coat.gif

  16   Wed Oct 7 14:24:06 2009 Dieter UhlBELLE Upgradehybrid#5hybrid-pitchadapter

shorts at upper coat

pitchadapter5_upper_coat.gif

 

opens at upper coat

pitchadapter5_upper_coat_opens.gif

 

shorts at lower coat

pitchadapter5_lower_coat.gif

 

opens at lower coat

pitchadapter5_lower_coat_opens.gif

  3   Wed Apr 23 13:05:05 2008 Christian IrmlerSPS Testbeam June08sourcehybrid 01time correlation between TDC and sensor measurement -> 3.1 ns RMS
  6   Wed May 7 15:24:49 2008 Christian IrmlerSPS Testbeam June08modulemodule 10/02properties (noise, intcal), APVs bonded to the sensor
Module tested with 1 and 2 rows bonded to the sensor, respectively. HV = 100 V Ibias (100V) = 19.1 nA Ibias (200V) = 23.7 nA
  9   Wed May 7 15:26:24 2008 Christian IrmlerSPS Testbeam June08modulemodule 20/09properties (noise, intcal), APVs bonded to the sensor
Module tested with 1 and 2 rows bonded to the sensor, respectively. HV = 100 V Ibias (100 V) = 25.1 nA Ibias (200 V) = 31.4 nA
ELOG V3.1.5-fc6679b