Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  RD50 MPW3 Beamtest at CERN SPS, Page 1 of 4  Not logged in ELOG logo
ID Date Author Subject DUT Threshold RefDetectors Run Number Events XYPosition Datadown
  17   Fri Oct 21 19:23:28 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa780 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

 

End result: AIDA TLU Stopped data taking and sending triggers after  40 minutes. Possible reaso : FEI4 stuck in busy, TLU error (whatever that may have been)

 

  19   Sat Oct 22 09:33:06 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa784 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Repeat of night run.

 

End of Run comment: Stopped after half hour, same issue as before

  20   Sat Oct 22 10:01:21 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa785 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 without busy (test if the FEI4 kills th run)

  22   Sat Oct 22 14:07:34 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa808 111mm/77.75mmUnknown

Repeat of ID 20 as it was interrupted

New Firmware with 64bit TS

FEI4 without busy (test if the FEI4 kills th run)

  23   Sat Oct 22 14:55:06 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa809 111mm/77.75mmUnknown

New Firmware with 64bit TS

FEI4 with busy (with timing for tracking)

Should give latest and greatest tracking results :)

 

  32   Sun Oct 23 11:31:58 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa818 111mm/77.75mmUnknown

another short one because the fei4 is so reliable :)

  58   Mon Oct 24 22:39:23 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa874-882 111mm/77.75mmUnknown
  59   Mon Oct 24 22:39:44 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa883 111mm/77.75mmUnknown

shortrun for checking after powercycling ZYNC

  61   Mon Oct 24 23:38:21 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa896 111mm/77.75mmUnknown

short run with old 100us UDP query

  62   Mon Oct 24 23:38:51 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa897 111mm/77.75mmUnknown

short run with new 1us UDP query again...

  63   Tue Oct 25 00:15:09 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa898 111mm/77.75mmUnknown

short run for t0 tests

  64   Tue Oct 25 00:15:19 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa899 111mm/77.75mmUnknown

short run for t0 tests

  65   Tue Oct 25 01:04:20 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa900-903 111mm/77.75mmUnknown

short run for t0 tests

  66   Tue Oct 25 01:07:26 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa904 111mm/77.75mmUnknown

short run for t0 tests

  67   Tue Oct 25 01:07:36 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa905 111mm/77.75mmUnknown

short run for t0 tests, start during spill

  68   Tue Oct 25 01:29:03 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa906-909 111mm/77.75mmUnknown

short runs for t0 tests and 30s noise test

  69   Tue Oct 25 11:42:29 2022 RD50 Generic UserNight runs with 1min noiseHEPHY_DUT11.2FEi4 | Mimosa910-925 111mm/77.75mmUnknown

short runs for t0 tests and 30s noise test

  1   Thu Oct 20 22:00:22 2022 RD50 Generic UserLong Night Run (Mimosa)none-Mimosa710 111mm/77.75mmGood

Needs to be checked for data integrity

  2   Thu Oct 20 22:05:18 2022 RD50 Generic Usershort test with FEI4none-FEi4 | Mimosa747 111mm/77.75mmGood

Needs to be checked for data integrity with FEI4

  3   Thu Oct 20 22:06:26 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa74862k on TLU111mm/77.75mmGood

Old software version -> No timestamp overflow or 64bit counter

Will try to fix software tomorrow

Mimosen are not in the mood of sending data -> restart mimosen

Data should be good

ELOG V3.1.5-fc6679b