Entry  Tue Jun 9 16:22:59 2015, Benedikt Würkner, SVD3 (H6B), Beam Profile Results, 66 und 67, , 2, No, Good HW_066_002_Result.pdfHW_066_003_Result.pdfHW_067_000_Result.pdfHW_067_001_Result.pdf
 
Entry  Sun Jun 7 10:39:56 2015, Hao Yin, Belle II FADC (H6A), Calibration, 002, , , , Good 

Cooled!
FIRRun002, pedestalrun006; temp see attachment in pedestalrun006
 

Entry  Tue Jun 9 09:33:33 2015, Hao Yin, Belle II FADC (H6A), Calibration, 003, , , , Good 

room temp
FIRRun002,
pedestalrun006;
pedestalrun007
 

Entry  Sun Jun 7 20:02:40 2015, Hao Yin, Belle II FADC (H6A), Cooling Box Emergency break, , , , , Unknown 

Something triggered a emergency break. HWRun012 only last 1-10k event has to be discarded.

Entry  Mon Jun 8 16:53:13 2015, Benedikt Würkner, SVD3 (H6B), EUTelescope Fitter not working investigation, , , , , Unknown nice-alignment.pngbad-alignment.png

Apparently every problem can be attributed to a misalignment problem. The telescope has troubles with heavily misaligned DUTs. Was resolved by creating different gear-files for each run with pretty precise coordinates of the DUT position calculated for the telescope coordinate system. 

Additionally one has to watch out for misaligned planes of the telescope itself. It was required to allow for more than 2mm offset for the telescope planes behind the DUTs. This can be easily checked by looking at the PreAligner plots in the -hitmaker-histo.root file.

It look something like this:

and not like this:

 

Run number offset value Comment
49 -1  
50 -1 Expected default value. EORE=49401
51 -1 Expected default value. EORE=49400
52 -1 Checked -1 EORE= 49401
53 -1 Checked -1 EORE= 49401
54 -1 Checked -1 EORE= 119401, 
55 -1 Checked -1 EORE= 409388
56 -1 Checked -1 EORE= 49392
57 -1 Checked -1 EORE= 49377
58 -1 Checked -1 EORE= 49397

 

Run Position x-Table x-telescope FW x-telescope BW
49 1 100 -13,7 -16,7
50 2 69,3 17 14
51 3 38,6 47,7 44,7
52 4 130,7 -44,4 -47,4
53 5 30,5 55,8 52,8
54 6 136,8 -50,5 -53,5
55 7 30,5 55,8 52,8
56 8 136,8 -50,5 -53,5
57 9 30,5 55,8 52,8
58 10 136,8 -50,5 -53,5
Entry  Wed Jun 10 18:05:03 2015, Benedikt Würkner, SVD3 (H6B), FEI4 configuration, , , , No, Unknown 

There are two planes, one fixed upstream and one fixed downstream. 

CIS3WII_6 upstream and CIS2WI_IBL2 downstream.

They are configured using the pc in H6B which can be accessed via microsoft remote desktop from the network 192.168.5.x using the ip 192.168.5.6. 

The configuration files can be found in the folder "E:\ConfigurationCMS\" on the server and are named after the modules. 

Only one of the FEI4 detectors can be used at a time since they are of different generations (FEI4A and FEI4B) which can't be used at the same time with the available USB board. vnc

The configuration for EUDAQ needs to be adapted for the used module by changing the name of the configuration file. 

[Producer.USBpixI4]
SRAM_READOUT_AT = 5
SkipConfiguration = no
UseSingleBoardConfig = no
boards = 230
modules[230] = 1
#upstream
config_file = E:\ConfigurationCMS\CIS3_W11_06_thr1600_7to21ke_modified.cfg.root
#downstream:
#config_file = E:\ConfigurationCMS\CIS2_W02_IBL1_thr1600_7to14_modified.cfg.root
fpga_firmware = E:\icwiki_svn\USBPixI4\host\tags\release-5.3\config\usbpixi4.bit
lvl1_delay = 16
tlu_trigger_data_delay = 10

In my experience switching between the planes also requires a restart of the USBPix DAQ because apparently something is not working with the reload of a different config file afterwards. I had the phenomenon that the DAQ responded like it was working but the datastream was empty. Therefore always check the online monitor for hitmaps. 

Entry  Thu Jun 4 14:15:50 2015, Hao Yin, Belle II FADC (H6A), FIR, 001, , , , Good 

FIR filer and ADC delay with all sensor and telescope.
telescope n-side switched.

Entry  Tue Jun 9 20:30:37 2015, Hao Yin, Belle II FADC (H6A), FIR, 004, , , , Good 

FIR filer and ADC delay with all sensor and telescope.
Telescope alignment

Entry  Fri Jun 12 09:31:58 2015, Hao Yin, Belle II FADC (H6A), FIR, 005, , , Yes, Good 

FIR filer and ADC delay for long sixlet cal run.

Entry  Thu Jun 4 15:12:41 2015, Hao Yin, Belle II FADC (H6A), Hardware, 001, 50000, 1, No, Good 20x

PedestalRun001, FIRRun001, room temp
telescope n-side switched.
In order to correct the position change the

Entry  Thu Jun 4 18:44:50 2015, Hao Yin, Belle II FADC (H6A), Hardware, 002, 50000, 2, No, Good 19x

room temp, FIRRun001, pedestal run 003

Entry  Thu Jun 4 22:07:16 2015, Hao Yin, Belle II FADC (H6A), Hardware, 003, 189k, 3, No, Good 21x

CE. pedestal run 003. Fir run 002. Room temp

Entry  Fri Jun 5 08:20:27 2015, Hao Yin, Belle II FADC (H6A), Hardware, 004, 50000, 4, No, Good 16x

room temp, FIRRun002, pedestalrun003, taget FW

Entry  Fri Jun 5 23:39:49 2015, Hao Yin, Belle II FADC (H6A), Hardware, 005, ~200k, 5, No, Good 21x

FIRRun002, pedestalrun005, room temp
Target BW: beam spot at ~ (0 p, 0 n)

Entry  Sat Jun 6 12:43:55 2015, Hao Yin, Belle II FADC (H6A), Hardware, 006, 50000, 6, No, Good 20x

FIRRun002, room temp, pedestalrun005,
layout: same as HW 005
target: -z, pos 6 (strip: p-0, n-0);

NOTE: results shown in the attachments has been evaluated with cmc containing 128 strip
 

Entry  Sat Jun 6 16:48:41 2015, Hao Yin, Belle II FADC (H6A), Hardware, 008, 50000, 8, No, Good 20x

room temp, FIRRun002, PedestalRun005, room temp

target: FW, pos 8 (p-0, n-0)

Entry  Sat Jun 6 23:30:29 2015, Benedikt Würkner, Belle II FADC (H6A), Hardware, 009, , , , Good 

room temp, FIRRun002, PedestalRun005, room temp

target: FW, pos 9 (p-0, n-128*4)

Entry  Sun Jun 7 13:19:19 2015, Hao Yin, Belle II FADC (H6A), Hardware, 010, , , , Good 

cooled

FIRRun002, PedestalRun006 (temp enty)

target: BW, pos 1

Entry  Sun Jun 7 13:21:15 2015, Hao Yin, Belle II FADC (H6A), Hardware, 011, 50000, , , Good Pos2.PNG

cooled (see attachment)

FIRRun002, PedestalRun006

target: -Z, pos 2

Entry  Sun Jun 7 15:59:05 2015, Hao Yin, Belle II FADC (H6A), Hardware, 012, 50000, , , Unknown Pos3.PNG

cooled (see attachment)

FIRRun002, PedestalRun006

target: CE, pos 2

cooling box emergency break ... ie about the last 1-10 k not useable.