Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, Page 6 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sat Nov 22 16:53:39 2014, Axel König, Infineon, Infineon old, Infineon_old_run001, 55000 , , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.9797uA
Entry  Sat Nov 22 17:00:43 2014, Axel König, Infineon, Infineon old, damaged strixel sensors, strange IV behaviour, , , , Unknown 
1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.
2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 
Entry  Sat Nov 22 18:08:03 2014, Axel König, Infineon, hardware run, Infineon_old_run002, 55000, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.9797uA
Entry  Sat Nov 22 19:29:40 2014, Axel König, AIDA, DUT Position, , , , , Unknown AIDA_DUT_Position.JPG
 
Entry  Sun Nov 23 00:20:41 2014, Axel König, Infineon, hardware run, Infineon_old_run003, 30000, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.9797uA
Entry  Sun Nov 23 00:24:15 2014, Axel König, Infineon, hardware run, Infineon_old_run004, 168725, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.6529uA
Entry  Sun Nov 23 00:51:07 2014, Axel König, Infineon, hardware run, Infineon_old_run005, 26569, , , Unknown 

    
      
 
            
            
Entry  Sun Nov 23 01:37:42 2014, Hao Yin, Belle SVD, HardwareRun, 040, 20000, 2014-11-23 01:37:00, , Unknown 
Bias voltage set to +-80V
Pedestal_015 (cooled) 

p, li { white-space: pre-wrap; }
"New" layout with no cooling (CO2 is no more)
Entry  Sun Nov 23 09:32:48 2014, Axel König, Infineon, hardware run, Infineon_old_run007, 63913, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.4028uA
Entry  Sun Nov 23 09:36:27 2014, Axel König, Infineon, hardware run, Infineon_old_run006, 526562, , , Unknown 
Infineon old
multi hit
Voltage=300V, I=10.4028uA
Entry  Sun Nov 23 09:49:00 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown temp_last_night.png
Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.
Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.
 
Entry  Sun Nov 23 10:32:41 2014, Hao Yin, Belle SVD, PedestalRun, 016, 10000, , , Unknown 
Pedestal Run 
room temperature (30C)
Bias scans planned
Entry  Sun Nov 23 10:51:49 2014, Hao Yin, Belle SVD, HardwareRun, 042, 76863, , , Unknown Temp_23-11-14.PNG
Hardware Run +-40V Bias
Room Temperature
Pedestal 016
Entry  Sun Nov 23 12:17:59 2014, Benedikt Würkner, Belle SVD, HardwareRun, 044, 20000, , , Unknown 
Hardware Run +-30V Bias
Room Temperature
Pedestal 017 (again marked all the bad strips)
Entry  Sun Nov 23 12:39:45 2014, Axel König, common, PMT's of EUDET (Igor Rubinsky), , , , , Unknown 
Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher
als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend
keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen
Entry  Sun Nov 23 12:55:47 2014, Benedikt Würkner, Belle SVD, HardwareRun, 045, 20000, , , Unknown 
Hardware Run +-50V Bias
Room Temperature
Pedestal 018 (again marked all the bad strips)
Entry  Sun Nov 23 15:07:54 2014, Markus Friedl, Belle SVD, common, , , , , Unknown fwbw_setup.png
Geometry setup of FW/BW:
(all dimensions are in mm and refer to the sensor planes)
Entry is currently edited by Thomas Bergauer on 193.170.243.91  Entry  Sun Nov 23 17:51:44 2014, Benedikt Würkner, Belle SVD, HardwareRun, 046, 100000, 20:06, 20:36, Unknown 
Hardware Run +-60V Bias
Room Temperature
Pedestal 018 (again marked all the bad strips)
ELOG V3.1.5-fc6679b