ID Date Authorup Project Subject Run Number Events StartTime EndTime Data
  107   Sun Nov 23 09:32:48 2014 Axel KönigInfineonhardware runInfineon_old_run00763913  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:96.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000999

DaqEvents: 63913 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

  108   Sun Nov 23 09:36:27 2014 Axel KönigInfineonhardware runInfineon_old_run006526562  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:95

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000998

DaqEvents: 526562 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

  113   Sun Nov 23 12:39:45 2014 Axel KönigcommonPMT's of EUDET (Igor Rubinsky)    Unknown

Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen).

  8   Sat Nov 15 12:41:50 2014 Benedikt WürknerBelle SVDDiscoveries during preliminary sensor tests    Unknown

L5_p_side APV #3 faulty signal

L4_n_side APV #2 and #3 faulty signal

Attachment 1: weird_signal.png
weird_signal.png
Attachment 2: faulty-signal-l4_n.png
faulty-signal-l4_n.png
Attachment 3: faulty-signal_l4_n_2.png
faulty-signal_l4_n_2.png
  35   Tue Nov 18 20:42:18 2014 Benedikt WürknerBelle SVDCoordinates of the DUT    Unknown

We set the coordinates trying to put the beam in an area with well working APVs

Peak of course differs for n and p sensors due to their different pitch.

L4-6 n-side Peak around strip 180

L4&6 p-side mean value around strip 380

L5 p-side moved by 4.8mm due to reasons (APV misalignment I think) therefore the peak of the same measurements is moved by 4.8/75µm = 64 strips therefore centered around strip 320

The coordinates of the x-y table were set to 0:0 at this point. Refer to Run Alignment2 for reference data.

  54   Thu Nov 20 10:33:13 2014 Benedikt WürknerBelle SVDFIRRun and Delay Scan003   Unknown

 Cooled see appendix

with new layout (l3_n-side channels changed and reactivated).

Latest FIRRun

Attachment 1: Temp_19-11-14.PNG
Temp_19-11-14.PNG
  55   Thu Nov 20 10:39:11 2014 Benedikt WürknerBelle SVDPedestalRun_009    Unknown

cooled see appendix (FIRRun003)

MaxEvents 10000

 

  56   Thu Nov 20 10:39:13 2014 Benedikt WürknerBelle SVDPedestalRun_009    Unknown

cooled see appendix (FIRRun003)

MaxEvents 10000

 

  57   Thu Nov 20 10:41:54 2014 Benedikt WürknerBelle SVDCalibrationRun_005    Unknown

 cooled see appendix (FIRRun_003)

PedestalRun_009

  59   Thu Nov 20 11:14:19 2014 Benedikt Würkner HardwareRun_009009   Crap

 cooling see attachment of FIRRun003

Ped 009

Cal 005

Multi 6 raw mode

L5_n_side out of order

 

FIFO_FULL_ERROR starting at ~2000 events

  71   Fri Nov 21 15:02:28 2014 Benedikt WürknerBelle SVDHardwareRun0131433  Unknown

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

  72   Fri Nov 21 15:03:08 2014 Benedikt WürknerBelle SVDHardwareRun014989  Unknown

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

  73   Fri Nov 21 15:07:24 2014 Benedikt WürknerBelle SVDHardwareRun0191509482014-11-21 02:41:552014-11-21 10:11:02Unknown

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

  74   Fri Nov 21 15:10:19 2014 Benedikt Würkner HardwareRun15-22 (exept 19) none  Crap
  93   Sat Nov 22 11:37:16 2014 Benedikt WürknerBelle SVDHardwareRun0364503782014-11-22 1:00:002014-11-22 10:27:54Unknown

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Attachment 1: SPS_Testbeam-Temp.xlsx
Attachment 2: Screen_Shot_2014-11-22_at_12.41.44.png
Screen_Shot_2014-11-22_at_12.41.44.png
  112   Sun Nov 23 12:17:59 2014 Benedikt WürknerBelle SVDHardwareRun04420000  Unknown

Hardware Run +-30V Bias

Room Temperature

Pedestal 017 (again marked all the bad strips)

Zero Suppressed

  114   Sun Nov 23 12:55:47 2014 Benedikt WürknerBelle SVDHardwareRun04520000  Unknown

Hardware Run +-50V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

Entry is currently edited by Thomas Bergauer on 193.170.243.91    120   Sun Nov 23 17:51:44 2014 Benedikt WürknerBelle SVDHardwareRun04610000020:0620:36Unknown

Hardware Run +-60V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

 

  4   Fri Nov 14 19:49:04 2014 Florian BuchsteinercommonBelle Setup    Unknown
Attachment 1: SPS_2014_Testbeam_-_Belle_Setup-Model.pdf
  10   Sun Nov 16 21:37:56 2014 Hao YincommonAIM    Unknown

fachi:  aimhephy@antispam.e4ward.com

chrisu:  gargamel0971

flo: flo.bux@sbg.at

shorty: martin@kurznet.net

markus; mueffi1040

hao: hao.yin@gmx.at

benni: benedikt.wuerkner@assoc.oeaw.ac.at

juan: juan.garcia.ferrero@cern.ch

axel: ???

bergi: callmebergi

ELOG V3.1.5-fc6679b