ID Dateup Author Project Subject Run Number Events StartTime EndTime
  103   Sat Oct 9 00:17:02 2010 Markus FriedlBELLErunrun056225k09.10.2010 00:15:5309.10.2010 09:54:28

Belle stack w/o Origami2 after irradiation
HV=80V / I_start=255 µA, I_stop=243 µA  

cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron (possibly due to burnt strip)

same position as in previous run

telescope run 20198 - now with correct telescope threshold settings

a lot of "Error detected in APV 21, subevent 2. Event discarded, reset sent." errors started at 09.10.2010 09:00:25 (after whole night without any error)

  104   Sat Oct 9 12:00:55 2010 Christian IrmlerBELLEcalcal0178380009.10.2010 11:59:37 

Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73°
HV=100V / 40 µA
cooling: chiller set to 15°C

Origami p-side does not receive triggers -> disabled

origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...

  105   Sat Oct 9 12:25:36 2010 Thomas BergauerBELLErunrun05727647509.10.2010 12:22:2109.10.2010 15:08:46

 

Origami1 (n-side only) + Micron1 (non-irrad)

angle scan: 73 degree

HV=100V / 36 uA  (beginning), 35uA (end of run)

cooling: chiller set to 15C

 PROBLEM: wrong config file (single hit, not multi6)

telescope run 20200

Origami p-side does not receive triggers -> disabled

origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...

 

  106   Sat Oct 9 15:29:09 2010 Markus FriedlBELLErunrun0583000009.10.2010 15:26:5009.10.2010 16:21:37

Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73 - now with multi6 (previous run was single)
HV=100V / 35uA (beginning of run) 34uA (end of run)
cooling: chiller set to 15C

telescope run 20201

Origami p-side does not receive triggers -> disabled

origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...

 

  107   Sat Oct 9 18:56:35 2010 Thomas Bergauercommonpath to telescope data    

eudetmac001.cern.ch

path is /Volumes/Data/eudet/Data/cern_2010_sept_silc_apvdaq (Vienna system)

and /Volumes/Data/eudet/Data/cern_2010_sept_silc_alibava (Santander system)

  108   Sat Oct 9 19:44:36 2010 Markus Friedlcommonend of success  09.10.2010 19:44:23NaN
  109   Sun Oct 10 15:45:04 2010 Thomas Bergauercommonend of success  09.10.2010 19:44:23NaN

 ;-) 

genau das gleiche wollte ich auch gerade schreiben!

  110   Mon Oct 11 11:18:17 2010 Christian Irmlercommonend of success  09.10.2010 19:44:23NaN

der Beiweis  :-)

Attachment 1: IMG_9033.JPG
IMG_9033.JPG
  111   Tue Oct 19 14:58:56 2010 Manfred ValentanMicron Babygeometry    
Attachment 1: IMG_8888.JPG
IMG_8888.JPG
Attachment 2: micron_baby_stack_telescope_geometry.JPG
micron_baby_stack_telescope_geometry.JPG
Attachment 3: micron_baby_stack_telectope_geometry.dwg
  112   Thu Mar 31 10:28:19 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfcal100 31.03.2011 10:24:5931.03.2011 10:33:15

DUT5
cal-file: micronbaby_single_irrad_cal100.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=99muA
I_end=103muA

 

  113   Thu Mar 31 11:05:39 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfrun100100k31.03.2011 11:02:1731.03.2011 11:15:41

DUT5
cal-file: micronbaby_multi6_irrad_run100.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=104µA
I_end=111µA

 

  114   Thu Mar 31 12:11:04 2011 Manfred ValentanMicron BabyDUT4, source run, post irrad, pre zupfcal101 31.03.2011 12:09:3631.03.2011 12:17:52

DUT4
config file: micronbaby_single_irrrad_cal101.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=140µA

 

  115   Thu Mar 31 12:24:24 2011 Manfred ValentanMicron BabyDUT4, source run, post irrad, pre zupfrun101100k31.03.2011 12:23:0031.03.2011 12:36:48

DUT4
config file: micronbaby_multi6_irrrad_run101.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=155µA

 

  116   Fri Apr 8 13:25:58 2011 Manfred ValentanMicron Babysensors and modules    

TRK1: B2Micron_2826_1_baby2

TRK2: B2Micron_2826_1_baby3

DUT3: B2Micron_2826_7_baby2 (common p-stop)

DUT4: B2Micron_2826_19_baby4 (combined p-stop)

DUT5: B2Micron_2826_19_baby3 (atoll p-stop)

TRK6: B2Micron_2826_1_baby4

TRK7: B2Micron_2826_19_baby2

GEW: B2Micron_2826_7_baby4

not used: B2Micron_2826_7_baby3

  117   Mon Apr 11 18:25:35 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfcal1048380011.04.2011 18:12:3811.04.2011 18:20:50

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=26µA
I_end=48µA

 

  118   Mon Apr 11 18:37:28 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfrun104100k11.04.2011 18:25:2811.04.2011 18:32:11

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=50µA
I_end=95µA

 

  119   Wed Apr 13 12:13:09 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupf ** DO NOT USE **cal1058380013.04.2011 12:02:4113.04.2011 12:10:55

DUT5 (atoll), each second bond removed to simulate intermediate strips
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=18µA
I_end=21.5µA

data recorded with new switching power supplies and old intcal, which doesn't ignore bad strips!!!!!

  120   Wed May 4 15:14:31 2011 Thomas BergauerPtinfo about module    

pt-Modul hat jeweils zwei OB1 Sensoren von STM (mit 122um Pitch)

im Abstand von 2mm uebereinander

  121   Wed May 11 16:28:07 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupfrun106100k11.05.2011 16:0011.05.2011 16:25

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA

 DAQ modified so that only strips marked as good are considered when calculating the common mode correction.

  122   Wed May 11 16:28:20 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupfcal106100k11.05.2011 16:0011.05.2011 16:25

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA

 DAQ modified so that only strips marked as good are considered when calculating the common mode correction.