Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  HEPHY logbook for testbeam at SPS September/October 2010, Page 3 of 8  Not logged in ELOG logo
ID Date Authorup Project Subject Run Number Events StartTime EndTime
  83   Mon Oct 4 23:12:16 2010 Manfred ValentanBELLErunrun443000004.10.2010 23:?:?04.10.2010 23.57.23

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 30°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -22.5 (rotary table)

telescope run: 20150

  84   Mon Oct 4 23:59:05 2010 Manfred ValentanBELLErunrun45 04.10.2010 ??:??:??05.10.2010 00:56:48

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 45°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -37.5 (rotary table)

telescope run: 20151

  85   Tue Oct 5 10:20:30 2010 Manfred ValentanBELLErunrun4635000005.10.2010 01:00:0005.10.2010 10:16:07

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 15°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -7.5 (rotary table)

telescope run: 20152

  86   Tue Oct 5 10:23:09 2010 Manfred ValentanBELLErunrun473000005.10.2010 10:21:2005.10.2010

angle scan Origami 1 and  Micron wedge 1
HV = 100V
chiller set to 14°C

angle: 0°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: +7.5 (rotary table)

telescope run: 20153

  101   Fri Oct 8 23:22:32 2010 Manfred ValentanBELLESchnittwinkel barrel vs. slanted    

17deg acceptance => Schnittwinkel barrel option = 90-17 = 73deg      ----->  rotary table 80.5

layer zusätzlich slanted um Winkel alpha => Schnittwinkel = 73 - alpha

slant angles: layer 4: 11.9deg => Schnittwinkel 61.1deg       ----->  rotary table 68.6
                     layer 5: 17.2deg => Schnittwinkel 55.8deg       ----->  rotary table 63.3
                     layer 6: 21.1deg => Schnittwinkel 51.9deg       ----->  rotary table 59.4

Im Vergleich mit senkrechtem Durchgang der Teilchen erwarte ich eine Vergrößerung der cluster width um den Faktor tan(Schnittwinkel):

slant layer 4: 1.81
slant layer 5: 1.47
slant layer 6: 1.28
barrel:           3.27

  111   Tue Oct 19 14:58:56 2010 Manfred ValentanMicron Babygeometry    
Attachment 1: IMG_8888.JPG
IMG_8888.JPG
Attachment 2: micron_baby_stack_telescope_geometry.JPG
micron_baby_stack_telescope_geometry.JPG
Attachment 3: micron_baby_stack_telectope_geometry.dwg
  112   Thu Mar 31 10:28:19 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfcal100 31.03.2011 10:24:5931.03.2011 10:33:15

DUT5
cal-file: micronbaby_single_irrad_cal100.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=99muA
I_end=103muA

 

  113   Thu Mar 31 11:05:39 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfrun100100k31.03.2011 11:02:1731.03.2011 11:15:41

DUT5
cal-file: micronbaby_multi6_irrad_run100.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=104µA
I_end=111µA

 

  114   Thu Mar 31 12:11:04 2011 Manfred ValentanMicron BabyDUT4, source run, post irrad, pre zupfcal101 31.03.2011 12:09:3631.03.2011 12:17:52

DUT4
config file: micronbaby_single_irrrad_cal101.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=140µA

 

  115   Thu Mar 31 12:24:24 2011 Manfred ValentanMicron BabyDUT4, source run, post irrad, pre zupfrun101100k31.03.2011 12:23:0031.03.2011 12:36:48

DUT4
config file: micronbaby_multi6_irrrad_run101.cfg


HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=155µA

 

  116   Fri Apr 8 13:25:58 2011 Manfred ValentanMicron Babysensors and modules    

TRK1: B2Micron_2826_1_baby2

TRK2: B2Micron_2826_1_baby3

DUT3: B2Micron_2826_7_baby2 (common p-stop)

DUT4: B2Micron_2826_19_baby4 (combined p-stop)

DUT5: B2Micron_2826_19_baby3 (atoll p-stop)

TRK6: B2Micron_2826_1_baby4

TRK7: B2Micron_2826_19_baby2

GEW: B2Micron_2826_7_baby4

not used: B2Micron_2826_7_baby3

  117   Mon Apr 11 18:25:35 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfcal1048380011.04.2011 18:12:3811.04.2011 18:20:50

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=26µA
I_end=48µA

 

  118   Mon Apr 11 18:37:28 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, pre zupfrun104100k11.04.2011 18:25:2811.04.2011 18:32:11

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=50µA
I_end=95µA

 

  119   Wed Apr 13 12:13:09 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupf ** DO NOT USE **cal1058380013.04.2011 12:02:4113.04.2011 12:10:55

DUT5 (atoll), each second bond removed to simulate intermediate strips
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=18µA
I_end=21.5µA

data recorded with new switching power supplies and old intcal, which doesn't ignore bad strips!!!!!

  121   Wed May 11 16:28:07 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupfrun106100k11.05.2011 16:0011.05.2011 16:25

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA

 DAQ modified so that only strips marked as good are considered when calculating the common mode correction.

  122   Wed May 11 16:28:20 2011 Manfred ValentanMicron BabyDUT5, source run, post irrad, post zupfcal106100k11.05.2011 16:0011.05.2011 16:25

DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA

 DAQ modified so that only strips marked as good are considered when calculating the common mode correction.

  123   Tue May 17 13:02:34 2011 Manfred ValentanMicron BabyTRK1, source run, unirrad, prezupfcal1078380017.05.2011 12:2017.05.2011 12:35

TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA

  124   Tue May 17 13:08:08 2011 Manfred ValentanMicron BabyTRK1, source run, unirrad, prezupfrun107100k17.05.2011 12:39:3417.05.2011 13:03:05

DUT candidate common p-stop

TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA

n-side: half of zones 1 and 4 obsolete due to noisy strips, rest is okay. DUT Candidate

Attachment 1: run107_all_hits_apv4.png
run107_all_hits_apv4.png
Attachment 2: run107_all_hits_apv5.png
run107_all_hits_apv5.png
Attachment 3: cal107_pednoise_apv4.png
cal107_pednoise_apv4.png
Attachment 4: cal107_pednoise_apv5.png
cal107_pednoise_apv5.png
  125   Tue May 17 13:31:32 2011 Manfred ValentanMicron BabyTRK2, source run, unirrad, prezupfcal1088380017.05.2011 13:17:1717.05.2011 13:25:27

TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.0µA
I_end=1.3µA

  126   Tue May 17 14:01:45 2011 Manfred ValentanMicron BabyTRK2, source run, unirrad, prezupfrun108100k17.05.2011 13:28:4817.05.2011 13:51:16

No DUT candidate (atoll p-stop)

TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=2µA

n-side: APV4 most strips unusable, no DUT candidate

Attachment 1: run108_all_hits_apv4.png
run108_all_hits_apv4.png
Attachment 2: run108_all_hits_apv5.png
run108_all_hits_apv5.png
Attachment 3: cal108_pednoise_apv4.png
cal108_pednoise_apv4.png
Attachment 4: cal108_pednoise_apv5.png
cal108_pednoise_apv5.png
ELOG V3.1.5-fc6679b