Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, Page 1 of 5  Not logged in ELOG logo
ID Date Author Projectup Subject Run Number Events StartTime EndTime Data
  17   Tue Jan 7 02:17:14 2014 Thomas Bergauer beam momentum 6GeV/crun013   Unknown
  21   Tue Jan 7 09:22:09 2014 Thomas Bergauer runrun01650k07.01.2014 09:19:1007.01.2014 09:30:03Good
HV=290V  I=9.00uA
position move back to original position (0mm/0mm) (not hitting the right APVs anymore)

DESY table z=-346 x=-255 

  22   Tue Jan 7 09:33:16 2014 Thomas Bergauer runrun017100k07.01.2014 09:31:4507.01.2014 09:52:58Good
HV=300V  I=9.08uA
position adapted to center beam better (+10mm horizonal)

DESY table z=-346 x=-255 

3Gev/c

  69   Thu Jan 23 22:47:49 2014 Hao Yin AIDACalibrationRun0018380023.01.2014 13:35:5523.01.2014 02:08:15Good

taken with tuxdaq...

HV=75V  I=?3.7uA?
position = 0 / -30 mm relative to initial (but again centered) ?
?5GeV beam, single sample? (software trigger run)
?narrow timing (trigger width)?

  70   Fri Jan 24 00:21:16 2014 Hao Yin AIDAHW_AIDA00140k24.02.2014 00:18 Unknown

HV=100V  I=3.7uA
position = 0 / -30 mm relative to initial (but again centered) no idea ---
3GeV beam, multipeak 6 samples
???narrow timing (trigger width)??? no idea ...

  72   Fri Jan 24 11:23:15 2014 Hao Yin AIDAHW_AIDA0037635624.02.2014 10:3024.02.2014 11:22Unknown

HV=100V  I=3.7uA
position = 0 / -30 mm relative to initial (but again centered) no idea ---
3GeV beam, multipeak 6 samples
???narrow timing (trigger width)??? no idea ...

  2   Sun Jan 5 15:08:09 2014 Markus FriedlAIDAcalcal0028380005.01.2014 15:01:3205.01.2014 15:30:36Good

HV=100V  I=6uA

  8   Mon Jan 6 19:31:44 2014 Markus FriedlAIDArunrun005200k06.01.2014 19:29:5206.01.2014 20:09:59Good

HV=230V  I=9.9uA

position centered horizontally (+5mm)

DESY table z=-346 x=-255

 

3 GeV beam momentum

  41   Wed Jan 8 12:40:30 2014 Thomas BergauerAIDAintcal AIDA Stackcal03483.8k08.01.2014 12:32:2208.01.2014 13:01:30Unknown

 HV=100V  I=4.5uA

position adapted to center beam
 
  42   Wed Jan 8 14:10:07 2014 Thomas BergauerAIDArunrun03521168108.01.2014 14:01:2508.01.2014 17:03:55Unknown

 HV=100V  I=4.2uA

position adapted to center beam
 

accidentally hit reset button on PC which ended this run abruptly...

 

5 GeV beam

  43   Wed Jan 8 17:20:40 2014 Markus FriedlAIDArunrun036320k08.01.2014 17:18:5108.01.2014 22:14:58Unknown

 HV=100V  I=4.3uA

centered position

5GeV beam

narrow timing (trigger width), but 6 samples

 

  44   Wed Jan 8 22:19:11 2014 Markus FriedlAIDArunrun0371.2M08.01.2014 22:18:3009.01.2014 10:08:14Good

HV=100V  I=4.4uA
centered position
5GeV beam, single sample
narrow timing (trigger width)

 

  45   Thu Jan 9 10:10:31 2014 Markus FriedlAIDAcalcal0388380009.01.2014 10:09:2709.01.2014 10:38:23Good

HV=100V  I=4.2uA
centered position
5GeV beam, single sample
narrow timing (trigger width)

  46   Thu Jan 9 11:02:14 2014 Markus FriedlAIDAinfo    Unknown

Created bad strip masks for the AIDA config files

  47   Thu Jan 9 11:04:34 2014 Markus FriedlAIDArunrun039100k09.01.2014 11:02:3609.01.2014 12:28:41Good

HV=10V  I=2.1uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)

 

  48   Thu Jan 9 12:31:29 2014 Markus FriedlAIDArunrun040100k09.01.2014 12:30:3209.01.2014 13:55:47Good

HV=20V  I=2.9uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)

 

  49   Thu Jan 9 14:07:31 2014 Markus FriedlAIDArunrun041100k09.01.2014 14:06:3209.01.2014 15:33:13Good

HV=30V  I=3.3uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)

 

  51   Thu Jan 9 16:36:30 2014 Markus FriedlAIDArunrun042100k09.01.2014 16:35:4309.01.2014 18:02:17Good

HV=40V  I=3.4uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)

 

  52   Thu Jan 9 18:09:40 2014 Markus FriedlAIDArunrun044100k09.01.2014 18:08:1909.01.2014 19:35:21Good

HV=50V  I=3.6uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)

MOVED TIMING by 1 clock (now signal is centered again)

  53   Thu Jan 9 19:37:33 2014 Markus FriedlAIDArunrun045100k09.01.2014 19:36:2109.01.2014 21:01:31 Good

HV=60V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
narrow timing (trigger width)

ELOG V3.1.5-fc6679b